Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Juan David Munoz-Bolanos has a total of 4 co-authors. Here are the top co-authors by number of shared publications:

  • Arkadiusz Miernik

    Department of Urology Faculty of Medicine, University of Freiburg ‐ Medical Centre Freiburg Baden‐Württemberg Germany

    2 shared publications
  • Christoph Krafft

    Leibniz Institute of Photonic Technology, Member of Leibniz Research Alliance Leibniz Health Technologies, Member of the Leibniz Center for Photonics in Infection Research, 07745 Jena, Germany

    2 shared publications
  • Jürgen Popp

    Institute of Physical Chemistry (IPC) and Abbe Center of Photonics (ACP) Friedrich Schiller University Jena Jena Germany

    2 shared publications
  • Tanveer Ahmed Shaik

    Leibniz Institute of Photonic Technology, Member of Leibniz Health Technologies, Member of the Leibniz Centre for Photonics in Infection Research (LPI), Jena, Germany

    2 shared publications

Latest Publications

  • Open Access

    Design of a Dispersive 1064 nm Fiber Probe Raman Imaging Spectrometer and Its Application to Human Bladder Resectates

    by Juan David Muñoz-Bolaños, Tanveer Ahmed Shaik, Arkadiusz Miernik, Jürgen Popp, Christoph Krafft

    This study introduces a compact Raman spectrometer with a 1064 nm excitation laser coupled with a fiber probe and an inexpensive motorized stage, offering a promising alternative to widely used Raman imaging instruments with 785 nm excitation lasers. The benefits of 1064 nm excitation for biomedical applications include further suppression of fluorescence background and deeper tissue penetration. The performance of the 1064 nm instrument in detecting cancer in human bladder resectates is demonstrated. Raman images with 1064 nm excitation were collected ex vivo from 10 human tumor and non-tumor bladder specimens, and the results are compared to previously published Raman images with 785 nm excitation. K-Means cluster (KMC) analysis is used after pre-processing to identify Raman signatures of control, tumor, necrosis, and lipid-rich tissues. Hierarchical cluster analysis (HCA) groups the KMC centroids of all specimens as input. The tools for data processing and hyperspectral analysis were compiled in an open-source Python library called SpectraMap (SpMap). In spite of lower spectral resolution, the 1064 nm Raman instrument can differentiate between tumor and non-tumor bladder tissues in a similar way to 785 nm Raman spectroscopy. These findings hold promise for future clinical hyperspectral Raman imaging, in particular for specimens with intense fluorescence background, e.g., kidney stones that are discussed as another widespread urological application.


  • Open Access

    Design of a Dispersive 1064 nm Fiber Probe Raman Imaging Spectrometer and Its Application to Human Bladder Resectates

    by Juan David Munoz-Bolanos, Tanveer Ahmed Shaik, Arkadiusz Miernik, Juergen Popp, Christoph Krafft

    This study introduces a compact Raman spectrometer with a 1064 nm excitation laser coupled with a fiber probe and an inexpensive motorized stage, offering a promising alternative to widely used Raman imaging instruments with 785 nm excitation lasers. The benefits of 1064 nm excitation for biomedical applications include further suppression of fluorescence background and deeper tissue penetration. The performance of the 1064 nm instrument in detecting cancer in human bladder resectates is demonstrated. Raman images with 1064 nm excitation were collected ex vivo from 10 human tumor and non-tumor bladder specimens and the results are compared to previously published Raman images with 785 nm excitation. K-Means cluster (KMC) analysis is used after pre-processing to identify Raman signatures of control, tumor, necrosis, and lipid-rich tissues. Hierarchical cluster analysis (HCA) groups the KMC centroids of all specimens as input. The tools for data processing and hyperspectral analysis were compiled in an open source Python library called SpectraMap (SpMap). In conclusion, the 1064 nm Raman system can differentiate between tumor and non-tumor bladder tissues in a similar way to 785 nm Raman spectroscopy. These findings hold promise for future clinical hyperspectral imaging.