Thanasis Athanasiou
Research Subjects
Thanasis Athanasiou has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- George Petekidis
FORTH
3 shared publications - Dimitris Vlassopoulos
Institute of Electronic Structure and Laser, FORTH, Heraklion, Greece
2 shared publications - Anastassia N. Rissanou
Institute of Theoretical and Physical Chemistry, National Hellenic Research Foundation, 48 Vassileos Konstantinou Ave, Athens 11635, Greece
1 shared publication - Anna Mitraki
Department of Materials Science and Engineering, University of Crete, Voutes Campus, 70013 Heraklion, Greece
1 shared publication - Antzela Noti
Department of Materials Science and Engineering, University of Crete, Voutes Campus, GR-70013 Heraklion, Greece
1 shared publication - Baicheng Mei
School of Materials Science and Engineering, Beijing Institute of Technology, Beijing 100081, China
1 shared publication
Latest Publications
- 1 September 2025
- Published by Society of Rheology in Journal of Rheology
- Vol. 69 (5) , 775-788
A double partition cone-plate piezorheometric tool to measure normal stress differences
The nonlinear rotational rheometry of viscoelastic materials such as polymer melts and solutions can become technically challenging due to the intervention of edge fracture instabilities when the shear rate increases. By using a cone-partitioned plate (CPP) fixture, i.e., an inner plate connected to the transducer and a nonmeasuring external partition fixed on rheometer's upper stage, one can significantly delay edge fracture in the inner plate and measure the shear stress over a wide range of shear rates, reaching a Rouse–Weissenberg number of 40 or more. However, to extract both the first and the second normal stress differences, two different CPP geometries and/or loadings are needed. To bypass this cumbersome approach, which is also prone to sample loading errors, it has been proposed to use two partitions, the so-called CPP3 geometry. In this arrangement, the inner partition serves as a second surface to measure the normal force signal. Earlier attempts were promising but measurements were too complicated and with limited temperature control. Here, we present CPP3+, a new fixture to measure the normal forces over a wide temperature range, which is based on the CPP3 concept. Our approach involves a piezoelectric sensor that is coaxially mounted on the inner partition, and the entire tool fits into the temperature control oven of a strain controlled rheometer. The stiffness of the piezoelectric sensor rules out any force-rebalance complexities, while its fast response provides high quality transient signals. We discuss the design and implementation of this simple and robust fixture and present data with entangled polymer solutions and melts to demonstrate the proof of concept. Still, the CPP3+ cannot be used above 80 °C, and edge fracture may affect the normal stress signal (and, in particular, the sensitive N2 data), something that could be mitigated in the future.
- 1 September 2025
- Published by Society of Rheology in Journal of Rheology
- Vol. 69 (5) , 775-788
A double partition cone-plate piezorheometric tool to measure normal stress differences
The nonlinear rotational rheometry of viscoelastic materials such as polymer melts and solutions can become technically challenging due to the intervention of edge fracture instabilities when the shear rate increases. By using a cone-partitioned plate (CPP) fixture, i.e., an inner plate connected to the transducer and a nonmeasuring external partition fixed on rheometer's upper stage, one can significantly delay edge fracture in the inner plate and measure the shear stress over a wide range of shear rates, reaching a Rouse–Weissenberg number of 40 or more. However, to extract both the first and the second normal stress differences, two different CPP geometries and/or loadings are needed. To bypass this cumbersome approach, which is also prone to sample loading errors, it has been proposed to use two partitions, the so-called CPP3 geometry. In this arrangement, the inner partition serves as a second surface to measure the normal force signal. Earlier attempts were promising but measurements were too complicated and with limited temperature control. Here, we present CPP3+, a new fixture to measure the normal forces over a wide temperature range, which is based on the CPP3 concept. Our approach involves a piezoelectric sensor that is coaxially mounted on the inner partition, and the entire tool fits into the temperature control oven of a strain controlled rheometer. The stiffness of the piezoelectric sensor rules out any force-rebalance complexities, while its fast response provides high quality transient signals. We discuss the design and implementation of this simple and robust fixture and present data with entangled polymer solutions and melts to demonstrate the proof of concept. Still, the CPP3+ cannot be used above 80 °C, and edge fracture may affect the normal stress signal (and, in particular, the sensitive N2 data), something that could be mitigated in the future.
- Open Access
- 8 June 2025
- Published by MDPI AG in Biomolecules
- Vol. 15 (6) , 839
FmocFF Peptide Hydrogel Is a Promising Matrix for Encapsulation and Controlled Release of the Anticancer Peptide Drug Bortezomib
One major public health issue is cancer chemotherapy; despite constant progress in the area, administration of anticancer drugs to patients is often associated with serious side effects. It is therefore imperative to develop vehicles for encapsulation and controlled delivery of such drugs. Anticancer drugs include small peptide drugs, such as Bortezomib (BTZ). Self-assembling peptides have been recently reported as promising drug delivery agents. The research reported here proposes the encapsulation of BTZ into peptide hydrogels formed by the self-assembling FmocFF dipeptide as delivery vehicle. We selected FmocFF as an encapsulation vehicle based on our previous simulation study on the complexation propensity of Bortezomib (BTZ) with various peptide gelators. Herein we undertook additional computational studies that highlight the benefits of FmocFF as a potential effective nanocarrier for BTZ combined with experiments of encapsulation and evaluation of BTZ release. Based on these computational and experimental results, we propose the Fmoc-FF dipeptide hydrogel as a promising matrix for the controlled delivery of BTZ.
- 8 June 2025
- Published by MDPI AG in Biomolecules
- Vol. 15 (6) , 839
Open AccessFmocFF Peptide Hydrogel Is a Promising Matrix for Encapsulation and Controlled Release of the Anticancer Peptide Drug Bortezomib
One major public health issue is cancer chemotherapy; despite constant progress in the area, administration of anticancer drugs to patients is often associated with serious side effects. It is therefore imperative to develop vehicles for encapsulation and controlled delivery of such drugs. Anticancer drugs include small peptide drugs, such as Bortezomib (BTZ). Self-assembling peptides have been recently reported as promising drug delivery agents. The research reported here proposes the encapsulation of BTZ into peptide hydrogels formed by the self-assembling FmocFF dipeptide as delivery vehicle. We selected FmocFF as an encapsulation vehicle based on our previous simulation study on the complexation propensity of Bortezomib (BTZ) with various peptide gelators. Herein we undertook additional computational studies that highlight the benefits of FmocFF as a potential effective nanocarrier for BTZ combined with experiments of encapsulation and evaluation of BTZ release. Based on these computational and experimental results, we propose the Fmoc-FF dipeptide hydrogel as a promising matrix for the controlled delivery of BTZ.
- Open Access
- 18 February 2025
- Published by Royal Society of Chemistry (RSC) in Soft Matter
- Vol. 21 (14) , 2607-2622
Probing cage dynamics in concentrated hard-sphere suspensions and glasses with high frequency rheometry
The HF crossover frequency, obtained from rheology (a), reflecting the extent of in-cage particle motion, exhibits two exponential regimes in accord with (b) non-linear Langevin theory with modified Verlet approximation predictions.
- 18 February 2025
- Published by Royal Society of Chemistry (RSC) in Soft Matter
- Vol. 21 (14) , 2607-2622
Open AccessProbing cage dynamics in concentrated hard-sphere suspensions and glasses with high frequency rheometry
The HF crossover frequency, obtained from rheology (a), reflecting the extent of in-cage particle motion, exhibits two exponential regimes in accord with (b) non-linear Langevin theory with modified Verlet approximation predictions.
- 15 April 2024
- Published by Society of Rheology in Journal of Rheology
- Vol. 68 (3) , 445-462
High-frequency optimally windowed chirp rheometry for rapidly evolving viscoelastic materials: Application to a crosslinking thermoset
Knowledge of the evolution in the mechanical properties of a curing polymer matrix is of great importance in composite parts or structure fabrication. Conventional rheometry, based on small amplitude oscillatory shear, is limited by long interrogation times. In rapidly evolving materials, time sweeps can provide a meaningful measurement albeit at a single frequency. To overcome this constraint, we utilize a combined frequency- and amplitude-modulated chirped strain waveform in conjunction with a homemade sliding plate piezo-operated rheometer (PZR) and a dual-head commercial rotational rheometer (Anton Paar MCR 702) to probe the linear viscoelasticity of these time-evolving materials. The direct controllability of the PZR, resulting from the absence of any kind of firmware and the microsecond actuator-sensor response renders this device ideal for exploring the advantages of this technique. The high frequency capability allows us to extend the upper limits of the accessible linear viscoelastic spectrum and, most importantly, to shorten the length of the interrogating strain signal (OWCh-PZR) to subsecond scales, while retaining a high time-bandwidth product. This short duration ensures that the mutation number (NMu) is kept sufficiently low, even in fast-curing resins. The method is validated via calibration tests in both instruments, and the corresponding limitations are discussed. As a proof of concept, the technique is applied to a curing vinylester resin. The linear viscoelastic (LVE) spectrum is assessed every 20 s to monitor the rapid evolution in the time and frequency dependence of the complex modulus. Comparison of the chirp implementation, based on parameters such as duration of the experiment, sampling frequency, and frequency range, in a commercial rotational rheometer with the PZR provides further information on the applicability of this technique and its limitations. Finally, FTIR spectroscopy is utilized to gain insights into the evolution of the chemical network, and the gap dependence of the evolving material properties in these heterogeneous systems is also investigated.
- 15 April 2024
- Published by Society of Rheology in Journal of Rheology
- Vol. 68 (3) , 445-462
High-frequency optimally windowed chirp rheometry for rapidly evolving viscoelastic materials: Application to a crosslinking thermoset
Knowledge of the evolution in the mechanical properties of a curing polymer matrix is of great importance in composite parts or structure fabrication. Conventional rheometry, based on small amplitude oscillatory shear, is limited by long interrogation times. In rapidly evolving materials, time sweeps can provide a meaningful measurement albeit at a single frequency. To overcome this constraint, we utilize a combined frequency- and amplitude-modulated chirped strain waveform in conjunction with a homemade sliding plate piezo-operated rheometer (PZR) and a dual-head commercial rotational rheometer (Anton Paar MCR 702) to probe the linear viscoelasticity of these time-evolving materials. The direct controllability of the PZR, resulting from the absence of any kind of firmware and the microsecond actuator-sensor response renders this device ideal for exploring the advantages of this technique. The high frequency capability allows us to extend the upper limits of the accessible linear viscoelastic spectrum and, most importantly, to shorten the length of the interrogating strain signal (OWCh-PZR) to subsecond scales, while retaining a high time-bandwidth product. This short duration ensures that the mutation number (NMu) is kept sufficiently low, even in fast-curing resins. The method is validated via calibration tests in both instruments, and the corresponding limitations are discussed. As a proof of concept, the technique is applied to a curing vinylester resin. The linear viscoelastic (LVE) spectrum is assessed every 20 s to monitor the rapid evolution in the time and frequency dependence of the complex modulus. Comparison of the chirp implementation, based on parameters such as duration of the experiment, sampling frequency, and frequency range, in a commercial rotational rheometer with the PZR provides further information on the applicability of this technique and its limitations. Finally, FTIR spectroscopy is utilized to gain insights into the evolution of the chemical network, and the gap dependence of the evolving material properties in these heterogeneous systems is also investigated.
- 1 August 2019
- Published by Springer Nature in Rheologica Acta
- Vol. 58 (9) , 619-637
A high-frequency piezoelectric rheometer with validation of the loss angle measuring loop: application to polymer melts and colloidal glasses
- 1 August 2019
- Published by Springer Nature in Rheologica Acta
- Vol. 58 (9) , 619-637
A high-frequency piezoelectric rheometer with validation of the loss angle measuring loop: application to polymer melts and colloidal glasses