HVHimanshu Vishwakarma
Himanshu Vishwakarma
*This is an algorithmically generated author record based on publicly available information.
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Himanshu Vishwakarma has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Pradipta Biswas
Indian Institute of Science, Bangalore, India
2 shared publications - Abhishek Mukhopadhyay
Amity University, Kolkata, India
1 shared publication - Anasol Pena-Rios
British Telecom Research Labs, Ipswich, UK
1 shared publication - Anugya Singh
Department of Design and Manufacturing, Indian Institute of Science, Bengaluru, India
1 shared publication - G. S. Rajshekar Reddy
Institute of Cognitive Science, University of Colorado Boulder, United States
1 shared publication - Naveen R. Talwar
CPDM, Indian Institute of Science, Bengaluru, India
1 shared publication
Latest Publications
- Open Access
- 15 April 2024
- Published by Springer Nature in Discover Analytics
- Vol. 2 (1) , 1-15
VR digital twin of office space with computer vision-based estimation of room occupancy and power consumption
In the past years, energy consumption has increased rapidly due to many factors, including the rise in technology adoption. This has many downfalls, from higher costs to CO $$_2$$ emissions. Human activities in offices and houses represent a considerable amount of energy usage. A digital twin (DT) of an open-plan common space is created, serving the purpose of remote room occupancy monitoring and automatic detection of energy consumption. A virtual reality (VR) model is developed and integrated to temperature, humidity and imaging sensors. For maintaining privacy, images are processed in local computers to measure occupancy levels and live video feed were never transmitted. The same set of imaging sensors were also used in a bespoke computer vision module for energy consumption estimation. The human avatars were mapped with high correlation (R $$^{2}$$ $$= 0.85$$ ) with actual positions on floor. Our energy consumption algorithm accuracy obtained true positive rate of $$91.58\%$$ and F1 score of $$81.96\%$$ . Finally, all this information is transmitted and visualized to the 3D digital twin for remote monitoring and simulation.- 15 April 2024
- Published by Springer Nature in Discover Analytics
- Vol. 2 (1) , 1-15
Open AccessVR digital twin of office space with computer vision-based estimation of room occupancy and power consumption
In the past years, energy consumption has increased rapidly due to many factors, including the rise in technology adoption. This has many downfalls, from higher costs to CO $$_2$$ emissions. Human activities in offices and houses represent a considerable amount of energy usage. A digital twin (DT) of an open-plan common space is created, serving the purpose of remote room occupancy monitoring and automatic detection of energy consumption. A virtual reality (VR) model is developed and integrated to temperature, humidity and imaging sensors. For maintaining privacy, images are processed in local computers to measure occupancy levels and live video feed were never transmitted. The same set of imaging sensors were also used in a bespoke computer vision module for energy consumption estimation. The human avatars were mapped with high correlation (R $$^{2}$$ $$= 0.85$$ ) with actual positions on floor. Our energy consumption algorithm accuracy obtained true positive rate of $$91.58\%$$ and F1 score of $$81.96\%$$ . Finally, all this information is transmitted and visualized to the 3D digital twin for remote monitoring and simulation.