Yoonhee Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yoonhee Lee has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- So Hyun Park
Department of Radiology, Gil Medical Center, Gachon University College of Medicine, Incheon, Korea
4 shared publications - Sungjin Yoon
Department of Radiology, Gil Medical Center, Gachon University College of Medicine, Incheon, Korea
3 shared publications - Dominik Nickel
Research & Clinical Translation, Magnetic Resonance, Siemens Healthineers AG Erlangen Germany
2 shared publications - Mun Young Paek
Siemens Healthineers Ltd., Seoul, Korea
2 shared publications - Dongyeob Han
Siemens Healthineers Ltd., Seoul, Korea
1 shared publication JaeKon Sung
Affiliation Siemens Healthineers Ltd, Seoul, Rebublic of Korea
1 shared publication
Latest Publications
- Open Access
- 1 January 2026
- Published by XMLink in Investigative Magnetic Resonance Imaging
- Vol. 30 (2) , 85
Deep Learning-Accelerated Magnetic Resonance Enterography for the Assessment of Crohn’s Disease
- 1 January 2026
- Published by XMLink in Investigative Magnetic Resonance Imaging
- Vol. 30 (2) , 85
Open AccessDeep Learning-Accelerated Magnetic Resonance Enterography for the Assessment of Crohn’s Disease
- Open Access
- 30 May 2025
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 20 (5) , e0320362
Deep learning reconstruction of free-breathing, diffusion-weighted imaging of the liver: A comparison with conventional free-breathing acquisition
This study aimed to compare image quality and solid focal liver lesion (FLL) assessments between free-breathing, diffusion-weighted imaging using deep learning reconstruction (FB-DL-DWI) and conventional DWI (FB-C-DWI) in patients undergoing clinically indicated liver MRIs. Our retrospective study included 199 patients who underwent 3 T-liver MRIs with FB-DL-DWI and FB-C-DWI. DWI was performed using a single-shot, spin-echo, echo-planar, fat suppression technique during free-breathing with matching parameters. Three radiologists independently evaluated subjective image quality across two sequences. The apparent diffusion coefficient (ADC) was measured in 15 liver regions. Four radiologists analyzed 138 solid FLLs from 60 patients for the presence of diffusion restriction, lesion conspicuity, and sharpness. Among the 199 patients, 110 (55.3%) had underlying chronic liver disease (CLD). FB-DL-DWI was found to be 43.0% faster than FB-C-DWI (119.4 ± 2.2 sec vs. 209.6 ± 3.7 sec). Furthermore, FB-DL-DWI scored higher than FB-C-DWI for all subjective image quality parameters (all, P < 0.001); however, FB-DL-DWI exhibited greater artificial sensation than FB-C-DWI (P < 0.001). In patients with CLD, FB-DL-DWI exhibited a better subjective image quality (all, P < 0.001) than FB-C-DWI. ADC values ranged from 1.06–1.12 × 10-3 mm2/sec in FB-DL-DWI and 1.06–1.20 × 10-3 mm2/sec in FB-C-DWI. Among the 138 lesions analyzed, 116 malignancies (61 hepatocellular carcinomas, 3 cholangiocarcinomas, 52 metastases) and 22 benignities were included. Four readers identified 88, 93, 93, and 105 diffusion-restricted FLLs in FB-DL-DWI and 84, 80, 98, and 95 in FB-C-DWI. FB-DL-DWI (75.9–90.5%) demonstrated comparable or superior diffusion restriction rates for malignant FLLs compared to FB-C-DWI (68.1–82.8%). Furthermore, FB-DL-DWI presented higher lesion-edge sharpness and lesion-conspicuity compared to FB-C-DWI. Overall, FB-DL-DWI provided better image quality, lesion sharpness, and conspicuity for solid FLLs, with a shorter acquisition time than FB-C-DWI. Therefore, FB-DL-DWI may replace FB-C-DWI as the preferred imaging method for liver evaluations.
- 30 May 2025
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 20 (5) , e0320362
Open AccessDeep learning reconstruction of free-breathing, diffusion-weighted imaging of the liver: A comparison with conventional free-breathing acquisition
This study aimed to compare image quality and solid focal liver lesion (FLL) assessments between free-breathing, diffusion-weighted imaging using deep learning reconstruction (FB-DL-DWI) and conventional DWI (FB-C-DWI) in patients undergoing clinically indicated liver MRIs. Our retrospective study included 199 patients who underwent 3 T-liver MRIs with FB-DL-DWI and FB-C-DWI. DWI was performed using a single-shot, spin-echo, echo-planar, fat suppression technique during free-breathing with matching parameters. Three radiologists independently evaluated subjective image quality across two sequences. The apparent diffusion coefficient (ADC) was measured in 15 liver regions. Four radiologists analyzed 138 solid FLLs from 60 patients for the presence of diffusion restriction, lesion conspicuity, and sharpness. Among the 199 patients, 110 (55.3%) had underlying chronic liver disease (CLD). FB-DL-DWI was found to be 43.0% faster than FB-C-DWI (119.4 ± 2.2 sec vs. 209.6 ± 3.7 sec). Furthermore, FB-DL-DWI scored higher than FB-C-DWI for all subjective image quality parameters (all, P < 0.001); however, FB-DL-DWI exhibited greater artificial sensation than FB-C-DWI (P < 0.001). In patients with CLD, FB-DL-DWI exhibited a better subjective image quality (all, P < 0.001) than FB-C-DWI. ADC values ranged from 1.06–1.12 × 10-3 mm2/sec in FB-DL-DWI and 1.06–1.20 × 10-3 mm2/sec in FB-C-DWI. Among the 138 lesions analyzed, 116 malignancies (61 hepatocellular carcinomas, 3 cholangiocarcinomas, 52 metastases) and 22 benignities were included. Four readers identified 88, 93, 93, and 105 diffusion-restricted FLLs in FB-DL-DWI and 84, 80, 98, and 95 in FB-C-DWI. FB-DL-DWI (75.9–90.5%) demonstrated comparable or superior diffusion restriction rates for malignant FLLs compared to FB-C-DWI (68.1–82.8%). Furthermore, FB-DL-DWI presented higher lesion-edge sharpness and lesion-conspicuity compared to FB-C-DWI. Overall, FB-DL-DWI provided better image quality, lesion sharpness, and conspicuity for solid FLLs, with a shorter acquisition time than FB-C-DWI. Therefore, FB-DL-DWI may replace FB-C-DWI as the preferred imaging method for liver evaluations.
- 28 May 2024
- Published by Springer Nature in Abdominal Radiology
- Vol. 49 (10) , 3615-3636
Advanced MRI techniques in abdominal imaging
Magnetic resonance imaging (MRI) is a crucial modality for abdominal imaging evaluation of focal lesions and tissue properties. However, several obstacles, such as prolonged scan times, limitations in patients’ breath-hold capacity, and contrast agent-associated artifacts, remain in abdominal MR images. Recent techniques, including parallel imaging, three-dimensional acquisition, compressed sensing, and deep learning, have been developed to reduce the scan time while ensuring acceptable image quality or to achieve higher resolution without extending the scan duration. Quantitative measurements using MRI techniques enable the noninvasive evaluation of specific materials. A comprehensive understanding of these advanced techniques is essential for accurate interpretation of MRI sequences. Herein, we therefore review advanced abdominal MRI techniques. Graphical abstract
- 28 May 2024
- Published by Springer Nature in Abdominal Radiology
- Vol. 49 (10) , 3615-3636
Advanced MRI techniques in abdominal imaging
Magnetic resonance imaging (MRI) is a crucial modality for abdominal imaging evaluation of focal lesions and tissue properties. However, several obstacles, such as prolonged scan times, limitations in patients’ breath-hold capacity, and contrast agent-associated artifacts, remain in abdominal MR images. Recent techniques, including parallel imaging, three-dimensional acquisition, compressed sensing, and deep learning, have been developed to reduce the scan time while ensuring acceptable image quality or to achieve higher resolution without extending the scan duration. Quantitative measurements using MRI techniques enable the noninvasive evaluation of specific materials. A comprehensive understanding of these advanced techniques is essential for accurate interpretation of MRI sequences. Herein, we therefore review advanced abdominal MRI techniques. Graphical abstract
- Open Access
- 1 January 2024
- Published by XMLink in Journal of the Korean Society of Radiology
- Vol. 85 (2) , 345-362
Advanced Abdominal MRI Techniques and Problem-Solving Strategies
이윤희, et al. J Korean Soc Radiol. 2024 Mar;85(2):345-362. https://doi.org/10.3348/jksr.2023.0067
- 1 January 2024
- Published by XMLink in Journal of the Korean Society of Radiology
- Vol. 85 (2) , 345-362
Open AccessAdvanced Abdominal MRI Techniques and Problem-Solving Strategies
이윤희, et al. J Korean Soc Radiol. 2024 Mar;85(2):345-362. https://doi.org/10.3348/jksr.2023.0067