MYMiao Yang

Miao Yang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Miao Yang has a total of 6 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Research on depth measurement calibration of light field camera based on Gaussian fitting

    by Miao Yang

    Optical field imaging technology does not require a complicated optical path layout and thus reduces hardware costs. Given that only one single exposure of a single camera can obtain three-dimensional information, this paper proposes an improved calibration method for depth measurement based on the theoretical model of optical field imaging. Specifically, the calibration time can be reduced since the Gaussian fitting can reduce the number of refocused images used to obtain the optimal refocusing coefficient calibration. Moreover, the proposed method achieves the same effect as the multiple refocusing calibration strategy but requires less image processing time during calibration. At the same time, this method's depth resolution is analyzed in detail.


  • Open Access

    Research on depth measurement calibration of light field camera based on Gaussian fitting

    by Miao Yang

    Optical field imaging technology does not require a complicated optical path layout and thus reduces hardware costs. Given that only one single exposure of a single camera can obtain three-dimensional information, this paper proposes an improved calibration method for depth measurement based on the theoretical model of optical field imaging. Specifically, the calibration time can be reduced since the Gaussian fitting can reduce the number of refocused images used to obtain the optimal refocusing coefficient calibration. Moreover, the proposed method achieves the same effect as the multiple refocusing calibration strategy but requires less image processing time during calibration. At the same time, this method's depth resolution is analyzed in detail.

  • Open Access

    Study on Distribution Characteristics of Gas-Liquid Two-Phase Flow in Pitot tube Sampler

    by Miao Yang, ZhiAn Deng, ZhiBo Cao, Jun Li, Zi Yan Wen

    Gas-liquid two-phase current systems are widely existed in the petroleum, the chemical industry, the metallurgy, the nuclear power and many industrial fields. Two-phase's phase distribution and measurement can't be avoided in two phase current system. And it is also a difficult problem that has not been solved. In this paper, we designed a pitot-distributor. Experimental measurement and theory analysis were carried out to study the distribution data and situation of the distributor in gas-liquid two-phase flow. Firstly, a special experimental device for pitot-distributor was designed and experiments were carried out at air-water two-phase flow loop. The main text pipeline's diameter is 50mm, the system pressure is 0.24~0.28MPa, there are five branches in the pitot-distributor, each branch's diameter is 8mm. The paper has first analyzed the influencing factors of gas extraction ratios and liquid extraction ratios, which were effected by four different types of pitot-separator. Next, it analyzed different efforts under two kind of pressure. Then, we established the math model and calculated the coefficients. Last, we analyzed the erroneous. The experimental result indicated that the tube-12345 structure is the perfect one which can keep extraction ratios more stable in a quite wide rang. Liquid extraction ratios (KL) mainly are affecting by the pressure and its structure. The gas extraction ratios (KG) mainly are affecting by the pressure.

  • Open Access

    Numerical simulation of separation characteristics of separator guide plate for CO2 flooding fluid

    by Yu Li, Miao Yang, Zhibo Cao, Jun Li

    In order to investigate the influence of the guide plate placement angle on the separation efficiency of CO2 flooding fluid, the separation characteristics of the horizontal separator guide plate were simulated by using ANSYS Fluent. Fitted the physical parameters of CO2 flooding fluid under the running condition of the separator, adopted the Mixture model of multiphase flow, and carried out the simulation of the guide plate placed at four placement angles (15°, 30°, 45°, 60°). The simulation results can provide a basis for designing a more efficient separator for CO2 flooding fluid.