Qiang Sun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Qiang Sun has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Yan-Peng Ge
State Key Laboratory of Power System Operation and Control Department of Electrical Engineering Tsinghua University Beijing China
3 shared publications Bo Liu
2 shared publicationsDengwei Ding
Sichuan Energy Internet Research Institute Tsinghua University Chengdu China
2 shared publicationsJiaqi Qu
State Key Laboratory of Intelligent Power Distribution Equipment and System Hebei University of Technology Tianjin China
2 shared publications- Jiaqi Qu
State Key Laboratory of Intelligent Power Distribution Equipment and System, Hebei University of Technology, Tianjin, China
2 shared publications Weidong Liu
State Key Laboratory of Power System Operation and Control Department of Electrical Engineering Tsinghua University Beijing China
2 shared publications
Latest Publications
- Open Access
- 22 October 2025
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 172
Robust multi-physics field reconstruction via sparse enclosure temperature measurements for GIL Digital Twin application
- 22 October 2025
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 172
Open AccessRobust multi-physics field reconstruction via sparse enclosure temperature measurements for GIL Digital Twin application
- Open Access
- 18 August 2025
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 10 (4) , 856-875
A novel GIS breakdown location method based on natural frequency of transient voltage
During on‐site withstand voltage tests of gas‐insulated switchgears (GIS), once a breakdown occurs, it is hard to locate the breakdown position due to the intricate branch structures and minimal breakdown energy. The existing methods may require the placement of a large number of sensors with unsatisfactory accuracy, which adversely affects the process of inspecting and repairing, as well as the subsequent tests. To address this issue, this paper introduces a novel GIS breakdown location method. This method is predicated on the natural frequency of the transient voltage caused by the breakdown. The relationship between the breakdown position and the natural frequency is first derived, which is referred to as the location equation. Then, the natural frequency characteristics are discussed from both mathematical and energy perspectives. Based on these characteristics, the location method is proposed that utilises the location equation and the frequencies at two measurement points. The results of the laboratory experiments demonstrate the accuracy of the method and certain advantages over the ultrasonic method. Further, the effectiveness of the method in GIS and gas‐insulated transmission lines (GIL) with complex structures and high voltage levels is also confirmed by simulation cases and field experimental data.
- 18 August 2025
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 10 (4) , 856-875
Open AccessA novel GIS breakdown location method based on natural frequency of transient voltage
During on‐site withstand voltage tests of gas‐insulated switchgears (GIS), once a breakdown occurs, it is hard to locate the breakdown position due to the intricate branch structures and minimal breakdown energy. The existing methods may require the placement of a large number of sensors with unsatisfactory accuracy, which adversely affects the process of inspecting and repairing, as well as the subsequent tests. To address this issue, this paper introduces a novel GIS breakdown location method. This method is predicated on the natural frequency of the transient voltage caused by the breakdown. The relationship between the breakdown position and the natural frequency is first derived, which is referred to as the location equation. Then, the natural frequency characteristics are discussed from both mathematical and energy perspectives. Based on these characteristics, the location method is proposed that utilises the location equation and the frequencies at two measurement points. The results of the laboratory experiments demonstrate the accuracy of the method and certain advantages over the ultrasonic method. Further, the effectiveness of the method in GIS and gas‐insulated transmission lines (GIL) with complex structures and high voltage levels is also confirmed by simulation cases and field experimental data.
- 15 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 21 (10) , 8121-8132
A Transferable Framework of PV Power Forecasting for Cross-Regional Distributed PV Systems Using Domain Adversarial Temporal Network
The lack of meteorological forecast data has increased the inaccuracy of output power forecasting in distributed photovoltaic systems. Especially, for newly built distributed sites across regions, modeling based on data-driven methods is limited by insufficient historical data. Therefore, a domain adversarial temporal network (DATN) based transfer learning (TL) framework is proposed, which contains two main modules, power temporal forecaster and domain classifier. Among them, the domain classifier considering the hidden layer weights of long short-term memory network is designed to reduce the distribution mismatch between source and target domains. The DATN employs a TL strategy of cross-domain adversarial pretraining with target-specific prediction tuning. In four cross-regional transfer experiments, the effects of domain adaptation methods and transfer strategies are compared. The breakthrough is that the transfer effect on different target data volumes is analyzed for the first time. The results prove that the proposed transferable framework DATN consistently performs best.
- 15 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 21 (10) , 8121-8132
A Transferable Framework of PV Power Forecasting for Cross-Regional Distributed PV Systems Using Domain Adversarial Temporal Network
The lack of meteorological forecast data has increased the inaccuracy of output power forecasting in distributed photovoltaic systems. Especially, for newly built distributed sites across regions, modeling based on data-driven methods is limited by insufficient historical data. Therefore, a domain adversarial temporal network (DATN) based transfer learning (TL) framework is proposed, which contains two main modules, power temporal forecaster and domain classifier. Among them, the domain classifier considering the hidden layer weights of long short-term memory network is designed to reduce the distribution mismatch between source and target domains. The DATN employs a TL strategy of cross-domain adversarial pretraining with target-specific prediction tuning. In four cross-regional transfer experiments, the effects of domain adaptation methods and transfer strategies are compared. The breakthrough is that the transfer effect on different target data volumes is analyzed for the first time. The results prove that the proposed transferable framework DATN consistently performs best.
- 23 September 2024
- Published by Elsevier in Electric Power Systems Research
- Vol. 238
Overvoltage phenomenon initiated by breakdown during on-site withstand voltage tests of GIL and GIS: Mechanisms and consequences
- 23 September 2024
- Published by Elsevier in Electric Power Systems Research
- Vol. 238
Overvoltage phenomenon initiated by breakdown during on-site withstand voltage tests of GIL and GIS: Mechanisms and consequences
- 16 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 39 (4) , 2065-2078
Accurate and Rapid 3D Full-Maxwell Simulations of Very Fast Transients in GIS Based on a Novel Busbar Voltage Setting Method
In 3D full-Maxwell simulations of very fast transients (VFTs), both accuracy and simulation efficiency pose challenges. The existing method cannot set simulation conditions appropriately, resulting in subpar simulation accuracy for the VFT process and unnecessary time consumption. Moreover, for the very fast transient overvoltage (VFTO) waveforms estimated by simulations, there is still a lack of specific analysis on waveform characteristics and appropriate verification methods. In this paper, a novel method that significantly improves both the accuracy and the time efficiency of the 3D full-Maxwell simulation of the VFT process is proposed. The wave process generated by breakdown is also analyzed to obtain the VFTO waveform characteristics for subsequent verification. Simulation cases, based on both a simplified GIS model and an actual GIS model, are demonstrated and discussed. Furthermore, a specially designed field test on the typical 1100 kV GIS, taking into account the residual voltage, is conducted for the simulation verification for the first time. The simulation and field test results align well in both the time domain and the time-frequency domain. Additionally, the novelty of this proposed method is demonstrated by comparing it with other existing method in case studies. The accuracy of the method has been shown to improve significantly, and the simulation time consumption can be reduced with the same computational machine and simulation configuration.
- 16 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 39 (4) , 2065-2078
Accurate and Rapid 3D Full-Maxwell Simulations of Very Fast Transients in GIS Based on a Novel Busbar Voltage Setting Method
In 3D full-Maxwell simulations of very fast transients (VFTs), both accuracy and simulation efficiency pose challenges. The existing method cannot set simulation conditions appropriately, resulting in subpar simulation accuracy for the VFT process and unnecessary time consumption. Moreover, for the very fast transient overvoltage (VFTO) waveforms estimated by simulations, there is still a lack of specific analysis on waveform characteristics and appropriate verification methods. In this paper, a novel method that significantly improves both the accuracy and the time efficiency of the 3D full-Maxwell simulation of the VFT process is proposed. The wave process generated by breakdown is also analyzed to obtain the VFTO waveform characteristics for subsequent verification. Simulation cases, based on both a simplified GIS model and an actual GIS model, are demonstrated and discussed. Furthermore, a specially designed field test on the typical 1100 kV GIS, taking into account the residual voltage, is conducted for the simulation verification for the first time. The simulation and field test results align well in both the time domain and the time-frequency domain. Additionally, the novelty of this proposed method is demonstrated by comparing it with other existing method in case studies. The accuracy of the method has been shown to improve significantly, and the simulation time consumption can be reduced with the same computational machine and simulation configuration.