Mehmet Gürdal Demirci
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Mehmet Gürdal Demirci has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Ahmet Karataş
Department of Rheumatology, Faculty of Medicine Firat University Elazig Turkey
1 shared publication - Alper Yıldırım
UNIVERSITY OF HEALTH SCIENCES, ADANA NUMUNE HEALTH RESEARCH CENTER
1 shared publication - Alperen Mengi
Department of Rheumatology, Faculty of Medicine, Samsun University, Samsun, Türkiye
1 shared publication - Aylin Dolu Karaca
Department of Rheumatology, Faculty of Medicine, Adıyaman University, Adıyaman, Türkiye
1 shared publication - Ayşe Nur Bayındır Akbaş
Department of Rheumatology, Denizli State Hospital, Denizli, Türkiye
1 shared publication - Burak Öz
Department of Rheumatology, Faculty of Medicine, Fırat University, Elazığ, Türkiye
1 shared publication
Latest Publications
- 23 October 2026
- Published by Springer Nature in Clinical Rheumatology
- Vol. 45 (12) , 7391-7399
Clinical characteristics of persistent ısotretinoin-associated ınflammatory back pain: a retrospective cohort study
- 23 October 2026
- Published by Springer Nature in Clinical Rheumatology
- Vol. 45 (12) , 7391-7399
Clinical characteristics of persistent ısotretinoin-associated ınflammatory back pain: a retrospective cohort study
- 3 March 2025
- Published by SAGE Publications in Surgical Innovation
- Vol. 32 (3) , 242-248
Virtual Colonoscopy: Retrospective Comparison of the Findings in Supine and Prone Positions
Background: Early detection of colorectal cancer (CRC) is significantly associated with reduced morbidity and mortality. Virtual colonoscopy (VC) is a minimally invasive, safe and well-tolerated alternative procedure to traditional colonoscopy. Therefore, we aimed to evaluate the findings of VC particularly in supine and prone positions as well as to contribute to the practical challenges of procedure. Methods: Total number of 20 patients who underwent VC were included in this retrospective study. After proper bowel cleansing was achieved, intestinal dilatation was performed by injecting air into the rectum. Two different shots were performed in the supine and prone positions. Additionally, intestinal diameters were measured from the cecum to the rectum at their widest point via 2-dimensional coronal reformat. Results: Polyps were detected in 3 patients which were confirmed by optical colonoscopy. The mean cecum diameter was detected as the largest diameter in the supine and prone examinations. In both supine and prone examinations, the distal descending colon was the most challenging site. Additionally, the mean descending colon diameter calculated in the prone position (40.9 ± 6.4 mm) was found to be statistically larger than descending colon diameter calculated in the supine position (36.1 ± 5.3 mm) ( P = 0.001). Conclusions: Our findings clearly demonstrated that combination of prone and supine scanning provides clear field of vision on narrow parts of the colon which improves accurate estimation for polyp detection. Furthermore, VC appears to be more comfortable, safe, fast, and cost-efffective procedure for CRC screening with advantages of low radiation exposure, extracolonic findings and lack of sedation requirements.
- 3 March 2025
- Published by SAGE Publications in Surgical Innovation
- Vol. 32 (3) , 242-248
Virtual Colonoscopy: Retrospective Comparison of the Findings in Supine and Prone Positions
Background: Early detection of colorectal cancer (CRC) is significantly associated with reduced morbidity and mortality. Virtual colonoscopy (VC) is a minimally invasive, safe and well-tolerated alternative procedure to traditional colonoscopy. Therefore, we aimed to evaluate the findings of VC particularly in supine and prone positions as well as to contribute to the practical challenges of procedure. Methods: Total number of 20 patients who underwent VC were included in this retrospective study. After proper bowel cleansing was achieved, intestinal dilatation was performed by injecting air into the rectum. Two different shots were performed in the supine and prone positions. Additionally, intestinal diameters were measured from the cecum to the rectum at their widest point via 2-dimensional coronal reformat. Results: Polyps were detected in 3 patients which were confirmed by optical colonoscopy. The mean cecum diameter was detected as the largest diameter in the supine and prone examinations. In both supine and prone examinations, the distal descending colon was the most challenging site. Additionally, the mean descending colon diameter calculated in the prone position (40.9 ± 6.4 mm) was found to be statistically larger than descending colon diameter calculated in the supine position (36.1 ± 5.3 mm) ( P = 0.001). Conclusions: Our findings clearly demonstrated that combination of prone and supine scanning provides clear field of vision on narrow parts of the colon which improves accurate estimation for polyp detection. Furthermore, VC appears to be more comfortable, safe, fast, and cost-efffective procedure for CRC screening with advantages of low radiation exposure, extracolonic findings and lack of sedation requirements.
- Open Access
- 16 April 2024
- Published by Springer Nature in Surgery Today
- Vol. 54 (10) , 1265-1271
Ultrasound-based predictive indicators for treatment outcomes in pediatric vesicoureteral reflux
Purpose: To evaluate the effectiveness of preoperative ultrasound (US) measurements in predicting pediatric vesicoureteral reflux (VUR) treatment outcomes. Methods: This prospective study enrolled 35 patients (53 renal units) aged 1–16 years who underwent subureteric injection therapy for primary VUR between July 2020 and June 2022. Preoperative ultrasound examinations measured the bladder wall thickness at the ureteral orifice, ureteral submucosal tunnel length, distal ureteral diameter, patient demographics, VUR grade, presenting complaints, bladder–bowel dysfunction, and renal scarring, and the impact of these variables on treatment success was analyzed. Results: Among the patients, 91.4% were female, with a mean age of 6.83 ± 3.84 years. A comparison between the treatment success and failure groups revealed no significant differences in the age, sex, VUR grade, laterality, bilaterality, presenting complaints, bladder–bowel dysfunction, bladder wall thickness, or distal ureteral diameter (p > 0.05). However, renal scarring occurred in 16 (38.1%) patients in the treatment success group and 10 (90.9%) in the treatment failure group (p = 0.002). The treatment failure group had shorter detrusor-to-ureteral orifice distances and smaller detrusor-ureteral orifice distance-to-distal ureteral diameter (D/U) ratios than that of the success group (p = 0.004 and p = 0.006, respectively). Patients with a detrusor-to-ureteral orifice distance < 7.4 mm had an 81.82% likelihood of treatment failure. Conclusion: Ultrasound measurements of the detrusor-to-ureteral orifice distance and D/U ratio proved reliable in predicting the success of endoscopic subureteric injection therapy for VUR.
- 16 April 2024
- Published by Springer Nature in Surgery Today
- Vol. 54 (10) , 1265-1271
Open AccessUltrasound-based predictive indicators for treatment outcomes in pediatric vesicoureteral reflux
Purpose: To evaluate the effectiveness of preoperative ultrasound (US) measurements in predicting pediatric vesicoureteral reflux (VUR) treatment outcomes. Methods: This prospective study enrolled 35 patients (53 renal units) aged 1–16 years who underwent subureteric injection therapy for primary VUR between July 2020 and June 2022. Preoperative ultrasound examinations measured the bladder wall thickness at the ureteral orifice, ureteral submucosal tunnel length, distal ureteral diameter, patient demographics, VUR grade, presenting complaints, bladder–bowel dysfunction, and renal scarring, and the impact of these variables on treatment success was analyzed. Results: Among the patients, 91.4% were female, with a mean age of 6.83 ± 3.84 years. A comparison between the treatment success and failure groups revealed no significant differences in the age, sex, VUR grade, laterality, bilaterality, presenting complaints, bladder–bowel dysfunction, bladder wall thickness, or distal ureteral diameter (p > 0.05). However, renal scarring occurred in 16 (38.1%) patients in the treatment success group and 10 (90.9%) in the treatment failure group (p = 0.002). The treatment failure group had shorter detrusor-to-ureteral orifice distances and smaller detrusor-ureteral orifice distance-to-distal ureteral diameter (D/U) ratios than that of the success group (p = 0.004 and p = 0.006, respectively). Patients with a detrusor-to-ureteral orifice distance < 7.4 mm had an 81.82% likelihood of treatment failure. Conclusion: Ultrasound measurements of the detrusor-to-ureteral orifice distance and D/U ratio proved reliable in predicting the success of endoscopic subureteric injection therapy for VUR.
- Open Access
- 2 January 2024
- Published by Springer Nature in Research Square
Virtual Colonoscopy: Clinical Advances and Practical Challenges
Background: Early detection of colorectal cancer (CRC) is significantly associated with reduced morbidity and mortality. Virtual colonoscopy (VC) is a minimally invasive, safe and well-tolerated alternative procedure to traditional colonoscopy. Therefore, we aimed to evaluate the findings of VC particularly in supine and prone positions as well as to contribute to the practical challenges of procedure. Methods:Total number of 20 patients who underwent VC were included in this retrospective study. After proper bowel cleansing was achieved, intestinal dilatation was performed by injecting air into the rectum. Two different shots were performed in the supine and prone positions. Additionally, intestinal diameters were measured from the cecum to the rectum at their widest point via 2-dimensional coronal reformat. Results: Polyps were detected in 3 patients which were confirmed by optical colonoscopy. The mean cecum diameter was detected as the largest diameter in the supine and prone examinations. In both supine and prone examinations, the distal descending colon was the most challenging site. Additionally, the mean descending colon diameter calculated in the prone position (40.9±6.4 mm) was found to be statistically larger than descending colon diameter calculated in the supine position (36.1±5.3 mm) (p=0.001). Conclusions: Our findings clearly demonstrated that combination of prone and supine scanning provides clear field of vision on narrow parts of the colon which improves accurate estimation for polyp detection. Furthermore, VC appears to be more comfortable, safe, fast, and cost-efffective procedure for CRC screening with advantages of low radiation exposure, extracolonic findings and lack of sedation requirements.
- 2 January 2024
- Published by Springer Nature in Research Square
Open AccessVirtual Colonoscopy: Clinical Advances and Practical Challenges
Background: Early detection of colorectal cancer (CRC) is significantly associated with reduced morbidity and mortality. Virtual colonoscopy (VC) is a minimally invasive, safe and well-tolerated alternative procedure to traditional colonoscopy. Therefore, we aimed to evaluate the findings of VC particularly in supine and prone positions as well as to contribute to the practical challenges of procedure. Methods:Total number of 20 patients who underwent VC were included in this retrospective study. After proper bowel cleansing was achieved, intestinal dilatation was performed by injecting air into the rectum. Two different shots were performed in the supine and prone positions. Additionally, intestinal diameters were measured from the cecum to the rectum at their widest point via 2-dimensional coronal reformat. Results: Polyps were detected in 3 patients which were confirmed by optical colonoscopy. The mean cecum diameter was detected as the largest diameter in the supine and prone examinations. In both supine and prone examinations, the distal descending colon was the most challenging site. Additionally, the mean descending colon diameter calculated in the prone position (40.9±6.4 mm) was found to be statistically larger than descending colon diameter calculated in the supine position (36.1±5.3 mm) (p=0.001). Conclusions: Our findings clearly demonstrated that combination of prone and supine scanning provides clear field of vision on narrow parts of the colon which improves accurate estimation for polyp detection. Furthermore, VC appears to be more comfortable, safe, fast, and cost-efffective procedure for CRC screening with advantages of low radiation exposure, extracolonic findings and lack of sedation requirements.