MDMehmet Gürdal Demirci

Mehmet Gürdal Demirci

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Mehmet Gürdal Demirci has a total of 40 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Clinical characteristics of persistent ısotretinoin-associated ınflammatory back pain: a retrospective cohort study

    by Fatih Albayrak, Orhan Zengin, Reha Baran, Mehmet Şakir Altuner, Osman Cüre, Ayşe Nur Bayındır, Özlem Kudaş, Rabia Sağır, Ozlem Dogan Agbuga, Lütfi Akyol, et al.

  • Virtual Colonoscopy: Retrospective Comparison of the Findings in Supine and Prone Positions

    by Mehmet Gürdal Demirci, Yasir Musa Kesgin

    Background: Early detection of colorectal cancer (CRC) is significantly associated with reduced morbidity and mortality. Virtual colonoscopy (VC) is a minimally invasive, safe and well-tolerated alternative procedure to traditional colonoscopy. Therefore, we aimed to evaluate the findings of VC particularly in supine and prone positions as well as to contribute to the practical challenges of procedure. Methods: Total number of 20 patients who underwent VC were included in this retrospective study. After proper bowel cleansing was achieved, intestinal dilatation was performed by injecting air into the rectum. Two different shots were performed in the supine and prone positions. Additionally, intestinal diameters were measured from the cecum to the rectum at their widest point via 2-dimensional coronal reformat. Results: Polyps were detected in 3 patients which were confirmed by optical colonoscopy. The mean cecum diameter was detected as the largest diameter in the supine and prone examinations. In both supine and prone examinations, the distal descending colon was the most challenging site. Additionally, the mean descending colon diameter calculated in the prone position (40.9 ± 6.4 mm) was found to be statistically larger than descending colon diameter calculated in the supine position (36.1 ± 5.3 mm) ( P = 0.001). Conclusions: Our findings clearly demonstrated that combination of prone and supine scanning provides clear field of vision on narrow parts of the colon which improves accurate estimation for polyp detection. Furthermore, VC appears to be more comfortable, safe, fast, and cost-efffective procedure for CRC screening with advantages of low radiation exposure, extracolonic findings and lack of sedation requirements.


  • Open Access

    Ultrasound-based predictive indicators for treatment outcomes in pediatric vesicoureteral reflux

    by Mehmet Öztürk, Haluk Şen, Feyza Yılmaz, Ömer Bayrak, Gürdal Demirci, Muharrem Baturu, M. Sakıp Erturhan, İlKer Seçkiner

    Purpose: To evaluate the effectiveness of preoperative ultrasound (US) measurements in predicting pediatric vesicoureteral reflux (VUR) treatment outcomes. Methods: This prospective study enrolled 35 patients (53 renal units) aged 1–16 years who underwent subureteric injection therapy for primary VUR between July 2020 and June 2022. Preoperative ultrasound examinations measured the bladder wall thickness at the ureteral orifice, ureteral submucosal tunnel length, distal ureteral diameter, patient demographics, VUR grade, presenting complaints, bladder–bowel dysfunction, and renal scarring, and the impact of these variables on treatment success was analyzed. Results: Among the patients, 91.4% were female, with a mean age of 6.83 ± 3.84 years. A comparison between the treatment success and failure groups revealed no significant differences in the age, sex, VUR grade, laterality, bilaterality, presenting complaints, bladder–bowel dysfunction, bladder wall thickness, or distal ureteral diameter (p > 0.05). However, renal scarring occurred in 16 (38.1%) patients in the treatment success group and 10 (90.9%) in the treatment failure group (p = 0.002). The treatment failure group had shorter detrusor-to-ureteral orifice distances and smaller detrusor-ureteral orifice distance-to-distal ureteral diameter (D/U) ratios than that of the success group (p = 0.004 and p = 0.006, respectively). Patients with a detrusor-to-ureteral orifice distance < 7.4 mm had an 81.82% likelihood of treatment failure. Conclusion: Ultrasound measurements of the detrusor-to-ureteral orifice distance and D/U ratio proved reliable in predicting the success of endoscopic subureteric injection therapy for VUR.


  • Open Access

    Virtual Colonoscopy: Clinical Advances and Practical Challenges

    by Mehmet Gürdal Demirci, Yasir Musa Kesgin

    Background: Early detection of colorectal cancer (CRC) is significantly associated with reduced morbidity and mortality. Virtual colonoscopy (VC) is a minimally invasive, safe and well-tolerated alternative procedure to traditional colonoscopy. Therefore, we aimed to evaluate the findings of VC particularly in supine and prone positions as well as to contribute to the practical challenges of procedure. Methods:Total number of 20 patients who underwent VC were included in this retrospective study. After proper bowel cleansing was achieved, intestinal dilatation was performed by injecting air into the rectum. Two different shots were performed in the supine and prone positions. Additionally, intestinal diameters were measured from the cecum to the rectum at their widest point via 2-dimensional coronal reformat. Results: Polyps were detected in 3 patients which were confirmed by optical colonoscopy. The mean cecum diameter was detected as the largest diameter in the supine and prone examinations. In both supine and prone examinations, the distal descending colon was the most challenging site. Additionally, the mean descending colon diameter calculated in the prone position (40.9±6.4 mm) was found to be statistically larger than descending colon diameter calculated in the supine position (36.1±5.3 mm) (p=0.001). Conclusions: Our findings clearly demonstrated that combination of prone and supine scanning provides clear field of vision on narrow parts of the colon which improves accurate estimation for polyp detection. Furthermore, VC appears to be more comfortable, safe, fast, and cost-efffective procedure for CRC screening with advantages of low radiation exposure, extracolonic findings and lack of sedation requirements.