Poul-Erik Hansen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Poul-Erik Hansen has a total of 99 co-authors. Here are the top co-authors by number of shared publications:
- Jonas Skovlund Madsen
Danish Fundamental Metrology A/S
4 shared publications - Jesper Nygård
Center for Quantum Devices & Nano-Science Center, Niels Bohr Institute, University of Copenhagen, Copenhagen, Denmark
3 shared publications Søren Alkærsig Jensen
Danish Fundamental Metrology A/S, Hørsholm, Denmark
3 shared publications- Aleksi Mattila
VTT MIKES
2 shared publications - Antti Lassila
VTT MIKES
2 shared publications Jørgen Garnæs
Danish Fundamental Metrology A/S
2 shared publications
Latest Publications
- Open Access
- 8 July 2026
- Published by IOP Publishing in Journal of Physics: Photonics
- Vol. 8 (3) , 035010
Correlative confocal and atomic force microscopy imaging for particle metrology: theory and measurements
Accurate and traceable determination of particle diameters is essential for environmental monitoring, pharmaceutical manufacturing, cleanroom contamination control and other critical infrastructure. Atomic force microscopy (AFM) provides a tactile solution for particle size calibration with the lowest measurement uncertainty and the highest spatial resolution in air; however, its practical application is constrained by limited scan range, low throughput, and challenges in reliably measuring particles larger than approximately 10 μ m. In contrast, high-throughput optical techniques such as laser scanning confocal microscopy (LSCM) offer large fields of view and extended measurement ranges but lack the resolution needed for dimensional particle metrology and measurements on translucent samples pose added challenges. Here, we present a correlative metrology framework that enables traceable calibration transfer between AFM and LSCM for translucent microparticles. By combining physics-informed modeling of near-field and confocal imaging effects with Bayesian inference for particle size estimation, we quantify and mitigate optical measurement biases and establish a statistically robust link between the two modalities. Using polystyrene particle standards, we demonstrate traceable size measurements across a range from 3 μ m to 20 μ m, extending the effective measurement capability beyond the practical limits of both instruments while maintaining the calculation of the expanded measurement uncertainty. This approach provides a general pathway for integrating high-throughput optical microscopy with high-resolution tactile metrology and highlights the role of physics-based modeling and probabilistic inference in enabling reliable dimensional measurements of complex objects.
- 8 July 2026
- Published by IOP Publishing in Journal of Physics: Photonics
- Vol. 8 (3) , 035010
Open AccessCorrelative confocal and atomic force microscopy imaging for particle metrology: theory and measurements
Accurate and traceable determination of particle diameters is essential for environmental monitoring, pharmaceutical manufacturing, cleanroom contamination control and other critical infrastructure. Atomic force microscopy (AFM) provides a tactile solution for particle size calibration with the lowest measurement uncertainty and the highest spatial resolution in air; however, its practical application is constrained by limited scan range, low throughput, and challenges in reliably measuring particles larger than approximately 10 μ m. In contrast, high-throughput optical techniques such as laser scanning confocal microscopy (LSCM) offer large fields of view and extended measurement ranges but lack the resolution needed for dimensional particle metrology and measurements on translucent samples pose added challenges. Here, we present a correlative metrology framework that enables traceable calibration transfer between AFM and LSCM for translucent microparticles. By combining physics-informed modeling of near-field and confocal imaging effects with Bayesian inference for particle size estimation, we quantify and mitigate optical measurement biases and establish a statistically robust link between the two modalities. Using polystyrene particle standards, we demonstrate traceable size measurements across a range from 3 μ m to 20 μ m, extending the effective measurement capability beyond the practical limits of both instruments while maintaining the calculation of the expanded measurement uncertainty. This approach provides a general pathway for integrating high-throughput optical microscopy with high-resolution tactile metrology and highlights the role of physics-based modeling and probabilistic inference in enabling reliable dimensional measurements of complex objects.
- Open Access
- 29 May 2025
- Published by Elsevier in Measurement
- Vol. 255
Bayesian approach for in Situ Numerical Aperture calibration and pitch determination in optical microscopy
- 29 May 2025
- Published by Elsevier in Measurement
- Vol. 255
Open AccessBayesian approach for in Situ Numerical Aperture calibration and pitch determination in optical microscopy
- Open Access
Digital Twins for 3D Confocal Microscopy: Near-Field, Far-Field, and Comparison with Experiments
To push the boundaries of confocal microscopy beyond its current limitations by predicting sensor responses for complex surface geometries, we build digital twins using three rigorous models, the finite element method (FEM), Fourier modal method (FMM), and boundary element method (BEM) to model light–surface interactions. Fourier optics are then used to calculate the sensor signals at the back focal plane and at the detector. A 3D illumination model is applied to 2D periodic structures for FEM and FMM modelings and to 3D aperiodic structures for BEM modeling. The lateral and vertical scanning processes of the confocal microscope are achieved through focal-point shifts of the objective, using plane-wave illuminations with varying incident and azimuthal angles. This approach reduces the need for repeated, time-intensive rigorous simulations of the scattering process when a fine scanning is desired. Furthermore, we give an in-depth description of a novel confocal microscopy method using FMM. For rectangular grating surfaces, the three models yield identical, highly accurate results, as validated by measured results. Simulations of the instrument transfer function, tilted gratings, and gratings with edge rounding offer insights into some experimentally observed effects. This research therefore provides a promising approach for correcting systematic errors in confocal microscopy.
Open AccessDigital Twins for 3D Confocal Microscopy: Near-Field, Far-Field, and Comparison with Experiments
To push the boundaries of confocal microscopy beyond its current limitations by predicting sensor responses for complex surface geometries, we build digital twins using three rigorous models, the finite element method (FEM), Fourier modal method (FMM), and boundary element method (BEM) to model light–surface interactions. Fourier optics are then used to calculate the sensor signals at the back focal plane and at the detector. A 3D illumination model is applied to 2D periodic structures for FEM and FMM modelings and to 3D aperiodic structures for BEM modeling. The lateral and vertical scanning processes of the confocal microscope are achieved through focal-point shifts of the objective, using plane-wave illuminations with varying incident and azimuthal angles. This approach reduces the need for repeated, time-intensive rigorous simulations of the scattering process when a fine scanning is desired. Furthermore, we give an in-depth description of a novel confocal microscopy method using FMM. For rectangular grating surfaces, the three models yield identical, highly accurate results, as validated by measured results. Simulations of the instrument transfer function, tilted gratings, and gratings with edge rounding offer insights into some experimentally observed effects. This research therefore provides a promising approach for correcting systematic errors in confocal microscopy.
- 14 March 2025
- Published by IOP Publishing in Metrologia
- Vol. 62 (2) , 025010
Instrumentation and uncertainty evaluation for absolute characterization of thin films and nanostructured surfaces in advanced optical metrology
The importance of traceable measurements is undeniable within an entire metrology community. However, due to their complexity, the optical measurement techniques suffer from the lack of guidelines regarding the measurement uncertainty evaluation. To address this issue, the paper describes the full procedure on how to perform a comprehensive characterization of advanced metrology instrumentation used in reflectometry, spectroscopic Mueller ellipsometry and optical scatterometry. Despite being fast and accurate, these contactless measurement techniques allow obtaining geometry imperfections, layer thicknesses, optical properties, impurities and other features, which can be hardly determined by other measurement techniques. The paper covers specular x-ray reflectometry and extreme ultra violet (EUV)-reflectometry to obtain the information on thin metal film thickness in the range 29 nm to 32 nm with uncertainties below 0.5 nm, as well as roughness values between 0.5 nm and 2 nm with uncertainties below 0.4 nm. The refractive index and extinction coefficient are determined by EUV-reflectometry at wavelengths of 14.5 nm and 15 nm. Furthermore, by using spectroscopic ellipsometry at national metrology institutes and research institutes, we cover the spectral range from 200 nm to 1200 nm, providing traceable measurements of thin film samples with nominal thicknesses of 30 nm as well as determining the refractive index and extinction coefficient of the thin Ru film, which range from 1 to 6 and display a relative standard uncertainty of less than 2%. In addition, the research looks into the reconstruction of the nanostructure geometry by optical scatterometry comparing the measurement results obtained by multiple scatterometry setups. For one dimensional repeated fused silica nanostructure we find height, line width and pitch values of 221.2 nm, 334.6 nm and 674.5 nm, with standard uncertainties of 2.7 nm, 3.6 nm and 3.0 nm. For two dimensional repeated silicon nanostructure we find height and width values of 122.2 nm and 244.9 with standard uncertainty of 2 nm and 1.2 nm. The methodology for uncertainty evaluation is provided together with actual uncertainty budgets and experimental results for each measurement technique. Measurement techniques cover the x-ray to IR spectral range to determine the optical constants through the measurements of layered nano-structures. Moreover, the inverse problem solving for optical measurement methods is explained in detail by providing the most useful approaches. The paper addresses, compares and summarizes the state of the art optical measurement techniques used in nanometrology.
- 14 March 2025
- Published by IOP Publishing in Metrologia
- Vol. 62 (2) , 025010
Instrumentation and uncertainty evaluation for absolute characterization of thin films and nanostructured surfaces in advanced optical metrology
The importance of traceable measurements is undeniable within an entire metrology community. However, due to their complexity, the optical measurement techniques suffer from the lack of guidelines regarding the measurement uncertainty evaluation. To address this issue, the paper describes the full procedure on how to perform a comprehensive characterization of advanced metrology instrumentation used in reflectometry, spectroscopic Mueller ellipsometry and optical scatterometry. Despite being fast and accurate, these contactless measurement techniques allow obtaining geometry imperfections, layer thicknesses, optical properties, impurities and other features, which can be hardly determined by other measurement techniques. The paper covers specular x-ray reflectometry and extreme ultra violet (EUV)-reflectometry to obtain the information on thin metal film thickness in the range 29 nm to 32 nm with uncertainties below 0.5 nm, as well as roughness values between 0.5 nm and 2 nm with uncertainties below 0.4 nm. The refractive index and extinction coefficient are determined by EUV-reflectometry at wavelengths of 14.5 nm and 15 nm. Furthermore, by using spectroscopic ellipsometry at national metrology institutes and research institutes, we cover the spectral range from 200 nm to 1200 nm, providing traceable measurements of thin film samples with nominal thicknesses of 30 nm as well as determining the refractive index and extinction coefficient of the thin Ru film, which range from 1 to 6 and display a relative standard uncertainty of less than 2%. In addition, the research looks into the reconstruction of the nanostructure geometry by optical scatterometry comparing the measurement results obtained by multiple scatterometry setups. For one dimensional repeated fused silica nanostructure we find height, line width and pitch values of 221.2 nm, 334.6 nm and 674.5 nm, with standard uncertainties of 2.7 nm, 3.6 nm and 3.0 nm. For two dimensional repeated silicon nanostructure we find height and width values of 122.2 nm and 244.9 with standard uncertainty of 2 nm and 1.2 nm. The methodology for uncertainty evaluation is provided together with actual uncertainty budgets and experimental results for each measurement technique. Measurement techniques cover the x-ray to IR spectral range to determine the optical constants through the measurements of layered nano-structures. Moreover, the inverse problem solving for optical measurement methods is explained in detail by providing the most useful approaches. The paper addresses, compares and summarizes the state of the art optical measurement techniques used in nanometrology.
- Open Access
- 20 February 2025
- Published by EDP Sciences in Journal of the European Optical Society-Rapid Publications
- Vol. 21 (1) , 7
Resolution enhancement methods in optical microscopy for dimensional optical metrology
In this paper, we discuss several enhancement approaches to increase the resolution and sensitivity of optical microscopy as a tool for dimensional nanometrology. Firstly, we discuss a newly developed through-focus microscopy technique providing additional phase information from the afocal images to increase the nanoscale sensitivity of classical microscopy. We also explore different routes to label-free or semiconductor compatible labelling super-resolution microscopy suitable for a broad range of technical applications. We present initial results from, a new wide-field super-resolution imaging technique enabled by Raman scattering. In addition, we discuss super-resolution imaging using NV centres in nano-diamonds as labels and their application in future reference standards.
- 20 February 2025
- Published by EDP Sciences in Journal of the European Optical Society-Rapid Publications
- Vol. 21 (1) , 7
Open AccessResolution enhancement methods in optical microscopy for dimensional optical metrology
In this paper, we discuss several enhancement approaches to increase the resolution and sensitivity of optical microscopy as a tool for dimensional nanometrology. Firstly, we discuss a newly developed through-focus microscopy technique providing additional phase information from the afocal images to increase the nanoscale sensitivity of classical microscopy. We also explore different routes to label-free or semiconductor compatible labelling super-resolution microscopy suitable for a broad range of technical applications. We present initial results from, a new wide-field super-resolution imaging technique enabled by Raman scattering. In addition, we discuss super-resolution imaging using NV centres in nano-diamonds as labels and their application in future reference standards.
- Open Access
- 28 October 2024
- Published by Elsevier in Journal of Computational Physics
- Vol. 521
Comparison of rigorous scattering models to accurately replicate the behaviour of scattered electromagnetic waves in optical surface metrology
- 28 October 2024
- Published by Elsevier in Journal of Computational Physics
- Vol. 521
Open AccessComparison of rigorous scattering models to accurately replicate the behaviour of scattered electromagnetic waves in optical surface metrology
- Open Access
- 31 May 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (8) , 085025
Artificial neural network assisted spectral scatterometry for grating quality control
Spectral scatterometry is a technique that allows rapid measurements of diffraction efficiencies of diffractive optical elements (DOEs). The analysis of such diffraction efficiencies has traditionally been laborious and time consuming. However, machine learning can be employed to aid in the analysis of measured diffraction efficiencies. In this paper we describe a novel system for providing measurements of multiple measurands rapidly and concurrently using a spectral scatterometer and an artificial neural network (ANN) which is trained utilising transfer learning. The ANN provides values for the pitch, height, and line widths of the DOEs. In addition, an uncertainty evaluation was performed. In the majority of the studied cases, the discrepancies between the values obtained using a scanning electron microscope (SEM) and artificial neural network assisted spectral scatterometer (ANNASS) for the grating parameters were below 5 nm. Furthermore, independent reference samples were used to perform a metrological validation. An expanded uncertainty (k = 2) of 5.3 nm was obtained from the uncertainty evaluation for the measurand height. The height value measurements performed employing ANNASS and SEM are demonstrated to be in agreement within this uncertainty.
- 31 May 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (8) , 085025
Open AccessArtificial neural network assisted spectral scatterometry for grating quality control
Spectral scatterometry is a technique that allows rapid measurements of diffraction efficiencies of diffractive optical elements (DOEs). The analysis of such diffraction efficiencies has traditionally been laborious and time consuming. However, machine learning can be employed to aid in the analysis of measured diffraction efficiencies. In this paper we describe a novel system for providing measurements of multiple measurands rapidly and concurrently using a spectral scatterometer and an artificial neural network (ANN) which is trained utilising transfer learning. The ANN provides values for the pitch, height, and line widths of the DOEs. In addition, an uncertainty evaluation was performed. In the majority of the studied cases, the discrepancies between the values obtained using a scanning electron microscope (SEM) and artificial neural network assisted spectral scatterometer (ANNASS) for the grating parameters were below 5 nm. Furthermore, independent reference samples were used to perform a metrological validation. An expanded uncertainty (k = 2) of 5.3 nm was obtained from the uncertainty evaluation for the measurand height. The height value measurements performed employing ANNASS and SEM are demonstrated to be in agreement within this uncertainty.
- Open Access
- 17 April 2024
- Published by AIP Publishing in Applied Physics Reviews
- Vol. 11 (2)
Deep-reactive ion etching of silicon nanowire arrays at cryogenic temperatures
The pursuit of sculpting materials at increasingly smaller and deeper scales remains a persistent subject in the field of micro- and nanofabrication. Anisotropic deep-reactive ion etching of silicon at cryogenic temperatures (cryo-DRIE) was investigated for fabricating arrays of vertically aligned Si nanowires (NWs) of a large range of dimensions from micrometers down to 30 nm in diameter, combined with commonly used wafer-scale lithography techniques based on optical, electron-beam, nanoimprint, and nanosphere/colloidal masking. Large selectivity of ∼100 to 120 and almost 700 was found with resists and chromium hard masks, respectively. This remarkable selectivity enables the successful transfer of patterned geometries while preserving spatial resolution to a significant extent. Depending on the requirements by applications, various shapes, profiles, and aspect ratios were achieved by varying process parameters synchronously or asynchronously. High aspect ratios of up to 100 comparable to the best result by metal-assisted wet-chemical etching and sub-μm trenches by DRIE were obtained with NW diameter of 200 nm, at an etch rate of ∼4 μm/min without being collapsed. At the same time, low surface roughness values were maintained on the NW top, sidewall, and bottom surface of ∼0.3, ∼13, and ∼2 nm, respectively, as well as high pattern fidelity and integrity, which were measured using angle-resolved Fourier microscopy, combined atomic force, and scanning electron microscopy on selected NWs. This work establishes the foundation in the controllable development of Si nanoarchitectures, especially at sub-100 nm structures, for energy-harvesting and storage, damage-free optoelectronics, quantum, photovoltaics, and biomedical devices.
- 17 April 2024
- Published by AIP Publishing in Applied Physics Reviews
- Vol. 11 (2)
Open AccessDeep-reactive ion etching of silicon nanowire arrays at cryogenic temperatures
The pursuit of sculpting materials at increasingly smaller and deeper scales remains a persistent subject in the field of micro- and nanofabrication. Anisotropic deep-reactive ion etching of silicon at cryogenic temperatures (cryo-DRIE) was investigated for fabricating arrays of vertically aligned Si nanowires (NWs) of a large range of dimensions from micrometers down to 30 nm in diameter, combined with commonly used wafer-scale lithography techniques based on optical, electron-beam, nanoimprint, and nanosphere/colloidal masking. Large selectivity of ∼100 to 120 and almost 700 was found with resists and chromium hard masks, respectively. This remarkable selectivity enables the successful transfer of patterned geometries while preserving spatial resolution to a significant extent. Depending on the requirements by applications, various shapes, profiles, and aspect ratios were achieved by varying process parameters synchronously or asynchronously. High aspect ratios of up to 100 comparable to the best result by metal-assisted wet-chemical etching and sub-μm trenches by DRIE were obtained with NW diameter of 200 nm, at an etch rate of ∼4 μm/min without being collapsed. At the same time, low surface roughness values were maintained on the NW top, sidewall, and bottom surface of ∼0.3, ∼13, and ∼2 nm, respectively, as well as high pattern fidelity and integrity, which were measured using angle-resolved Fourier microscopy, combined atomic force, and scanning electron microscopy on selected NWs. This work establishes the foundation in the controllable development of Si nanoarchitectures, especially at sub-100 nm structures, for energy-harvesting and storage, damage-free optoelectronics, quantum, photovoltaics, and biomedical devices.
- Open Access
- 19 January 2022
- Published by Frontiers Media SA in Frontiers in Physics
- Vol. 9
Enhanced Measurement Accuracy for Nanostructures Using Hybrid Metrology
Light-matter interplay is widely used for analyzing the topology of surfaces on small scales for use in areas such as nanotechnology, nanoelectronics, photonics, and advanced materials. Conventional optical microscope imaging methods are limited in resolution to a value comparable to the wavelength, the so-called Abbe limit, and cannot be used to measure nano-sized structures. Scatterometry and Mueller ellipsometry are spectroscopic optical methods that can measure structures smaller than the wavelength. However, the relative uncertainties of the structure dimensions measured with scatterometry increase with decreasing structure size, and the industry is therefore replacing simple intensity based scatterometry with Mueller ellipsometry for the most demanding measurements. The accuracy of Mueller ellipsometry and scatterometry are closely related to the ability of the employed regression and regularization algorithms to extract the structural dimension. In this work, we demonstrate how the measurement accuracy on three-dimensional periodic structures may be increased by measuring the same periodic structure with multiple techniques and applying a χ2-regression method that finds the best solution based on the input from all the instruments. We furthermore report on a new and improved calibration method for Mueller ellipsometry and demonstrate how the Mueller matrix may be used to find the geometrical anisotropy of the structure.
- 19 January 2022
- Published by Frontiers Media SA in Frontiers in Physics
- Vol. 9
Open AccessEnhanced Measurement Accuracy for Nanostructures Using Hybrid Metrology
Light-matter interplay is widely used for analyzing the topology of surfaces on small scales for use in areas such as nanotechnology, nanoelectronics, photonics, and advanced materials. Conventional optical microscope imaging methods are limited in resolution to a value comparable to the wavelength, the so-called Abbe limit, and cannot be used to measure nano-sized structures. Scatterometry and Mueller ellipsometry are spectroscopic optical methods that can measure structures smaller than the wavelength. However, the relative uncertainties of the structure dimensions measured with scatterometry increase with decreasing structure size, and the industry is therefore replacing simple intensity based scatterometry with Mueller ellipsometry for the most demanding measurements. The accuracy of Mueller ellipsometry and scatterometry are closely related to the ability of the employed regression and regularization algorithms to extract the structural dimension. In this work, we demonstrate how the measurement accuracy on three-dimensional periodic structures may be increased by measuring the same periodic structure with multiple techniques and applying a χ2-regression method that finds the best solution based on the input from all the instruments. We furthermore report on a new and improved calibration method for Mueller ellipsometry and demonstrate how the Mueller matrix may be used to find the geometrical anisotropy of the structure.
- 1 May 2020
- Published by Wiley in Computer Graphics Forum
- Vol. 39 (2) , 729-755
Survey of Models for Acquiring the Optical Properties of Translucent Materials
The outset of realistic rendering is a desire to reproduce the appearance of the real world. Rendering techniques therefore operate at a scale corresponding to the size of objects that we observe with our naked eyes. At the same time, rendering techniques must be able to deal with objects of nearly arbitrary shapes and materials. These requirements lead to techniques that oftentimes leave the task of setting the optical properties of the materials to the user. Matching the appearance of real objects by manual adjustment of optical properties is however nearly impossible. We can render objects with a plausible appearance in this way but cannot compare the appearance of a manufactured item to that of its digital twin. This is especially true in the case of translucent objects, where we need more than a goniometric measurement of the optical properties. In this survey, we provide an overview of forward and inverse models for acquiring the optical properties of translucent materials. We map out the efforts in graphics research in this area and describe techniques available in related fields. Our objective is to provide a better understanding of the tools currently available for appearance specification when it comes to digital representations of real translucent objects.
- 1 May 2020
- Published by Wiley in Computer Graphics Forum
- Vol. 39 (2) , 729-755
Survey of Models for Acquiring the Optical Properties of Translucent Materials
The outset of realistic rendering is a desire to reproduce the appearance of the real world. Rendering techniques therefore operate at a scale corresponding to the size of objects that we observe with our naked eyes. At the same time, rendering techniques must be able to deal with objects of nearly arbitrary shapes and materials. These requirements lead to techniques that oftentimes leave the task of setting the optical properties of the materials to the user. Matching the appearance of real objects by manual adjustment of optical properties is however nearly impossible. We can render objects with a plausible appearance in this way but cannot compare the appearance of a manufactured item to that of its digital twin. This is especially true in the case of translucent objects, where we need more than a goniometric measurement of the optical properties. In this survey, we provide an overview of forward and inverse models for acquiring the optical properties of translucent materials. We map out the efforts in graphics research in this area and describe techniques available in related fields. Our objective is to provide a better understanding of the tools currently available for appearance specification when it comes to digital representations of real translucent objects.