Minxin Wei
Research Subjects
Research Interests
Minxin Wei has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Bailang Chen
Department of Cardiovascular Surgery, The University of Hong Kong-Shenzhen Hospital
3 shared publicationsXianmian Zhuang
Department of Cardiovascular Surgery, The University of Hong Kong-Shenzhen Hospital
2 shared publications- Zanxin Wang
Division of Cardiovascular Surgery, Cardiac and Vascular Center, The University of Hong Kong-Shenzhen Hospital, Shenzhen, Guangdong, 518000, China
2 shared publications - Peijun Li
Division of Cardiovascular Intensive Care (C-ICU), Cardiac and Vascular Center, The University of Hong Kong-Shenzhen Hospital , Guangdong 518000
1 shared publication Rui Zhang
Department of Cardiovascular Surgery, The University of Hong Kong-Shenzhen Hospital
1 shared publicationShuaishuai Yuan
Division of Cardiovascular Intensive Care (C-ICU), Cardiac and Vascular Center, The University of Hong Kong-Shenzhen Hospital , Guangdong 518000
1 shared publication
Latest Publications
- Open Access
- 4 November 2026
- Published by Frontiers Media SA in Frontiers in Surgery
- Vol. 13, 1970445
Intraoperative measurement of the ascending aortic diameter at the onset of aortic dissection
Background: Although prior studies have associated aortic size with dissection risk, none have corrected for dissection-related aortic expansion. This study aimed to establish a measurement approach to determine the ascending aortic diameter before dissection. Methods: The samples of dissected ascending aortas were obtained from 36 patients at the time of their operation. In this study, the intimal lumen diameter measured at its maximal stretching state was used as a reliable surrogate for the pre-dissection aortic diameter. Subsequently, the relationship between this surrogate and the aortic diameter measured on post-dissection CT at the corresponding levels was further analyzed. Results: Using this method, the pre-dissection ascending aortic diameter was measured as 37.5 ± 6.6 mm, whereas the post-dissection CT measurement at the same level increased to 43.9 ± 7.0 mm. After excluding patients with non-A-non-B aortic dissection, the mean ascending aortic diameter increased by approximately 20% after dissection compared with the pre-dissection value, corresponding to an absolute increase of 7.5 mm in diameter. Conclusions: Although aortic diameter remains a robust indicator for prophylactic surgery in the study population, acute aortic dissection is seldom associated with true ascending aortic aneurysms and occurs with normal or near-normal aortic dimensions in most patients. When dissection occurs in the setting of a small aortic diameter, it likely reflects a profound functional vulnerability of the aortic tissue to catastrophic aortic events.
- 4 November 2026
- Published by Frontiers Media SA in Frontiers in Surgery
- Vol. 13, 1970445
Open AccessIntraoperative measurement of the ascending aortic diameter at the onset of aortic dissection
Background: Although prior studies have associated aortic size with dissection risk, none have corrected for dissection-related aortic expansion. This study aimed to establish a measurement approach to determine the ascending aortic diameter before dissection. Methods: The samples of dissected ascending aortas were obtained from 36 patients at the time of their operation. In this study, the intimal lumen diameter measured at its maximal stretching state was used as a reliable surrogate for the pre-dissection aortic diameter. Subsequently, the relationship between this surrogate and the aortic diameter measured on post-dissection CT at the corresponding levels was further analyzed. Results: Using this method, the pre-dissection ascending aortic diameter was measured as 37.5 ± 6.6 mm, whereas the post-dissection CT measurement at the same level increased to 43.9 ± 7.0 mm. After excluding patients with non-A-non-B aortic dissection, the mean ascending aortic diameter increased by approximately 20% after dissection compared with the pre-dissection value, corresponding to an absolute increase of 7.5 mm in diameter. Conclusions: Although aortic diameter remains a robust indicator for prophylactic surgery in the study population, acute aortic dissection is seldom associated with true ascending aortic aneurysms and occurs with normal or near-normal aortic dimensions in most patients. When dissection occurs in the setting of a small aortic diameter, it likely reflects a profound functional vulnerability of the aortic tissue to catastrophic aortic events.
- Open Access
- 2 May 2025
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 9 (5) , ytaf217
‘Localized’ constrictive pericarditis
- 2 May 2025
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 9 (5) , ytaf217
Open Access‘Localized’ constrictive pericarditis
- Open Access
- 28 November 2024
- Published by Elsevier in Asian Journal of Surgery
- Vol. 48 (5) , 3106-3107
Percutaneous management of cerebral malperfusion prior to surgery for acute type A dissection accompanied by severe common carotid artery stenosis
- 28 November 2024
- Published by Elsevier in Asian Journal of Surgery
- Vol. 48 (5) , 3106-3107
Open AccessPercutaneous management of cerebral malperfusion prior to surgery for acute type A dissection accompanied by severe common carotid artery stenosis
- 18 April 2024
- Published by Massachusetts Medical Society in New England Journal of Medicine
- Vol. 390 (15) , 1420
Aortic Coarctation
- 18 April 2024
- Published by Massachusetts Medical Society in New England Journal of Medicine
- Vol. 390 (15) , 1420
Aortic Coarctation