Shan Jiang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Shan Jiang has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Dong Chen
School of Civil Engineering, Anhui Jianzhu University, Hefei 230601, China
2 shared publications Dong Chen
1 shared publicationHao Xuan
1 shared publication- Hao Xuan
School of Civil Engineering, Anhui Jianzhu University, Hefei, China
1 shared publication - Haoran Li
Anhui BIM Engineering Center, Anhui Jianzhu University, Hefei 230601, China
1 shared publication - Ling-Wei Kong
School of Civil Engineering, Anhui Jianzhu University, Hefei, China
1 shared publication
Latest Publications
- 11 February 2026
- Published by Springer Nature in Journal of Civil Structural Health Monitoring
- Vol. 16 (2) , 26
A safety state assessment method for cofferdam hydraulic structures based on digital images and artificial neural network
- 11 February 2026
- Published by Springer Nature in Journal of Civil Structural Health Monitoring
- Vol. 16 (2) , 26
A safety state assessment method for cofferdam hydraulic structures based on digital images and artificial neural network
- Open Access
Post-Fire Mechanical Properties of Half-Grouted Sleeve Connectors with Grouting Defects
Half-grouted sleeve connectors are a primary method for connecting rebar in prefabricated concrete structures. However, due to limitations in the construction environment, all kinds of grouting defects are inevitable, especially grouting voids. Additionally, fire disasters, among the most common types of disasters, significantly threaten the structural performance and safety of these prefabricated structures. Therefore, it is imperative to determine the mechanical properties of half-grouted sleeve connectors with grouting voids after high temperatures. This study designed and prepared 48 groups of half-grouted sleeve specimens with different grouting voids and defect locations. These specimens were heated to the specified temperature (25 °C, 200 °C, 300 °C, 400 °C, 500 °C, 600 °C), followed by unidirectional tensile testing after natural cooling. The experimental results showed that rebar fracture failure and rebar pulled-out failure were the failure modes of specimens. With the increase in temperature, bearing capacity, safety factor and ductility coefficient of specimens all decreased. When the temperature was lower than 400 °C, the specimen with void length less than twice the diameter of the rebar (i.e., 2d) had sufficient connection performance. For specimens with the same total void lengths, the bearing capacity of discrete voids is lower than concentrate voids at the same temperature. The load-displacement curve, safety coefficient, ductility coefficient and grey correlation degree of half-grouted sleeve specimens with grouting voids at different temperatures are analyzed and discussed, and the bond stress slip constitutive model is given. Grouting defects have greater influence on specimens after grey correlation analysis. Findings from this study provide valuable references for the safety performance evaluation of prefabricated structures with half-grouted sleeve connectors after exposure to fire.
Open AccessPost-Fire Mechanical Properties of Half-Grouted Sleeve Connectors with Grouting Defects
Half-grouted sleeve connectors are a primary method for connecting rebar in prefabricated concrete structures. However, due to limitations in the construction environment, all kinds of grouting defects are inevitable, especially grouting voids. Additionally, fire disasters, among the most common types of disasters, significantly threaten the structural performance and safety of these prefabricated structures. Therefore, it is imperative to determine the mechanical properties of half-grouted sleeve connectors with grouting voids after high temperatures. This study designed and prepared 48 groups of half-grouted sleeve specimens with different grouting voids and defect locations. These specimens were heated to the specified temperature (25 °C, 200 °C, 300 °C, 400 °C, 500 °C, 600 °C), followed by unidirectional tensile testing after natural cooling. The experimental results showed that rebar fracture failure and rebar pulled-out failure were the failure modes of specimens. With the increase in temperature, bearing capacity, safety factor and ductility coefficient of specimens all decreased. When the temperature was lower than 400 °C, the specimen with void length less than twice the diameter of the rebar (i.e., 2d) had sufficient connection performance. For specimens with the same total void lengths, the bearing capacity of discrete voids is lower than concentrate voids at the same temperature. The load-displacement curve, safety coefficient, ductility coefficient and grey correlation degree of half-grouted sleeve specimens with grouting voids at different temperatures are analyzed and discussed, and the bond stress slip constitutive model is given. Grouting defects have greater influence on specimens after grey correlation analysis. Findings from this study provide valuable references for the safety performance evaluation of prefabricated structures with half-grouted sleeve connectors after exposure to fire.