IMInhong Min

Inhong Min

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Inhong Min has a total of 6 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    An Analysis of Greenhouse Gas Emissions in Electrolysis for Certifying Clean Hydrogen

    by Yunji Kim, Inhong Min, Jieun Lee, Heena Yang

    The drive for carbon neutrality has led to legislative measures targeting reduced greenhouse gas emissions across the transportation, construction, and industry sectors. Renewable energy sources, especially solar and wind power, play a pivotal role in this transition. However, their intermittent nature necessitates effective storage solutions. Green hydrogen and ammonia have gained attention for their potential to store renewable energy while producing minimal emissions. Despite their theoretical promise of zero greenhouse gas emissions during production, real-world emissions vary based on system configurations and lifecycle assessments, highlighting the need for detailed evaluations of their environmental impact. Therefore, in this study, calculations were performed for the actual amount of produced greenhouse gas emissions that are associated with the production of green hydrogen using electrolysis, from raw material extraction and processing to hydrogen production, with these assessed from well-to-gate emission estimates. Emissions were also evaluated based on various types of renewable energy sources in South Korea, as well as hydrogen production volumes, capacities, and types. Using these data, the following factors were examined in this study: carbon dioxide emissions from the manufacturing stage of electrolysis equipment production, the correlation between materials and carbon dioxide emissions, and process emissions. Current grades of clean hydrogen were verified, and the greenhouse gas reduction effects of green hydrogen were confirmed. These findings are significant against the backdrop of a country such as South Korea, where the proportion of renewable energy in total electricity production is very low at 5.51%. Based on the domestic greenhouse gas emission efficiency standard of 55 kWh/kgH2, it was found that producing 1 kg of hydrogen emits 0.076 kg of carbon dioxide for hydropower, 0.283 kg for wind power, and 0.924 kg for solar power. The carbon dioxide emissions for AWE and PEM stacks were 8434 kg CO2 and 3695 kg CO2, respectively, demonstrating that an alkaline water electrolysis (AWE) system emits about 2.3 times more greenhouse gasses than a proton exchange membrane (PEM) system. This indicates that the total carbon dioxide emissions of green hydrogen are significantly influenced by the type of renewable energy and the type of electrolysis used.


  • Open Access

    CFD Analysis of the Pressure Drop Caused by the Screen Blockage Rate in a Membrane Strainer

    by Inhong Min, Jongwoong Choi, Gwangjae Kim, Hyunsik Jo

    Autostrainer is used for the purpose of debris removal in order to increase the efficiency of the heat exchanger by taking the required raw water as a heat source for the pre-cooling hydrothermal system. During the operation of the autostrainer, a pressure drop occurs due to the blockage of the screen in the autostrainer. As a result, the resistance of the pipe network for the intake system is changed, and the operating efficiency point of the pump, valve, heat exchanger, etc., is altered. By calculating the system resistance taking into account the pressure drop caused by the blockage rate of the screen in the autostrainer, the optimum operating efficiency can be expected when the intake system such as a pump, valve or heat exchanger, etc. is constructed. In this study, Computational Fluid Dynamics (CFD) was used to construct a scenario in which screen blockage may occur, predicting pressure drop for the slot cross-section of the screen in the autostrainer to derive a resistance coefficient value. The resistance coefficient value was applied to the porous region corresponding to the screen in the autostrainer’s 3D shape and compared with the experimental value for the pressure drop and headloss coefficient. By predicting the pressure drop for the autostrainer’s screen blockage rate of 0% to 50%, the coefficient of headloss required for the design of the intake system was calculated. Additionally, in order to predict the debris removal rate, which is the original role of the autostrainer, the debris was assumed to be particles, and sedimentation rate was predicted according to the size and weight of the particles. Building on this, when introducing the autostrainer used in pre-cooling into the membrane filtration process, due to the pressure loss caused by the inflow of debris during the use of the autostrainer, this study aims to utilize Computational Fluid Dynamics (CFD) to derive the head loss coefficients according to the screen blockage rate, and use these coefficients to calculate the system’s resistance curve. Additionally, in this study, the term “autostrainer” is used instead of the term “membrane strainer” to align with more popular terminology.