Peter Scougall
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Peter Scougall has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- William Robert Walsh
Surgical and Orthopedic Research Laboratories (SORL), Prince of Wales Clinical School, Faculty of Medicine, Prince of Wales Clinical School, University of New South Wales (UNSW) Sydney New South Wales Australia
2 shared publications A. Jhamb
Sydney and St Luke's Hospitals and Surgical and Orthopaedic Research Laboratories University of New South Wales, Sydney, Australia
1 shared publicationAndrew Clout
Surgical & Orthopaedic Research Laboratories (SORL), Prince of Wales Hospital, Prince of Wales Clinical School, University of New South Wales, Randwick, NSW, Australia
1 shared publicationDamian Ryan
MBBS, FRACS (Orth); Hand Surgery Clinic, Sydney Hospital, Sydney, New South Wales, AUSTRALIA
1 shared publication- Danè Dabirrahmani
Macquarie University
1 shared publication G. Wernecke
Sydney and St Luke's Hospitals and Surgical and Orthopaedic Research Laboratories University of New South Wales, Sydney, Australia
1 shared publication
Latest Publications
- Open Access
- 29 September 2022
- Published by Australian Society of Plastic Surgeons in Australasian Journal of Plastic Surgery
- Vol. 5 (2) , 37-43
Smartphone goniometer for reliable and convenient measurement of finger range of motion: a comparative study
**Objective**: Goniometer measurements are commonly used in hand clinics to follow progress or as an outcome measure for acute and chronic conditions. The use of a smartphone goniometer application may provide a practical alternative for clinicians. This study sought to assess accuracy in range-of-motion measurements obtained by a smartphone goniometer application compared to a traditional universal goniometer in healthy and diseased hands.**Methods**: Patients with various hand disease processes were recruited through a tertiary hospital hand clinic, as well as healthy volunteers. Middle and little fingers were assessed at the metacarpophalangeal (MCP), proximal interphalangeal (PIP) and distal interphalangeal (DIP) joints for flexion and extension. Measurements were taken using a universal goniometer and an iPhone® smartphone goniometer application by two independent evaluators using a standardised proforma.**Results**: Twenty patients were recruited (50% male; 13 healthy volunteers and seven with hand pathology). There were no significant differences in measurements using the smartphone goniometer. The only significant difference found using the universal goniometer was for little finger PIP joint flexion; however, the difference was only 2.5°. Comparison of the average measurements using universal and smartphone goniometers found significant differences for six joints, with none of these >5° (largest 4.6°).**Conclusion**: The goniometer iPhone® application is as reliable as traditional goniometry techniques and would be a practical tool for everyday use in hand clinics. Its uptake may provide broader utility for patient self-measurement and telemedicine.
- 29 September 2022
- Published by Australian Society of Plastic Surgeons in Australasian Journal of Plastic Surgery
- Vol. 5 (2) , 37-43
Open AccessSmartphone goniometer for reliable and convenient measurement of finger range of motion: a comparative study
**Objective**: Goniometer measurements are commonly used in hand clinics to follow progress or as an outcome measure for acute and chronic conditions. The use of a smartphone goniometer application may provide a practical alternative for clinicians. This study sought to assess accuracy in range-of-motion measurements obtained by a smartphone goniometer application compared to a traditional universal goniometer in healthy and diseased hands.**Methods**: Patients with various hand disease processes were recruited through a tertiary hospital hand clinic, as well as healthy volunteers. Middle and little fingers were assessed at the metacarpophalangeal (MCP), proximal interphalangeal (PIP) and distal interphalangeal (DIP) joints for flexion and extension. Measurements were taken using a universal goniometer and an iPhone® smartphone goniometer application by two independent evaluators using a standardised proforma.**Results**: Twenty patients were recruited (50% male; 13 healthy volunteers and seven with hand pathology). There were no significant differences in measurements using the smartphone goniometer. The only significant difference found using the universal goniometer was for little finger PIP joint flexion; however, the difference was only 2.5°. Comparison of the average measurements using universal and smartphone goniometers found significant differences for six joints, with none of these >5° (largest 4.6°).**Conclusion**: The goniometer iPhone® application is as reliable as traditional goniometry techniques and would be a practical tool for everyday use in hand clinics. Its uptake may provide broader utility for patient self-measurement and telemedicine.
- 28 September 2022
- Published by World Scientific Pub Co Pte Ltd in The Journal of Hand Surgery (Asian-Pacific Volume)
- Vol. 27 (05) , 816-823
Cyclic Testing of a Modified Pull-Out Suture Repair Technique for Flexor Digitorum Profundus Avulsion in a Turkey Foot Model
Background: Numerous repair techniques have been described for closed flexor digitorum profundus (FDP) avulsion. One option is a pull-out suture tied over the nail plate (Bunnell repair). We modified the Bunnell repair by incorporating a portion of the distal interphalangeal (DIP) joint volar plate into the repair to improve strength and reduce gapping. The aim of this study is to compare gap formation and load to failure between the Bunnell repair and our modification in a turkey foot model. Methods: Twenty-four fresh-frozen cadaveric turkey feet were divided into two repair groups namely the conventional Bunnell pull-out suture technique and the modified Bunnell pull-out suture technique, incorporating the middle-third of the DIP joint volar plate into the repair. Both repairs were carried out with 3-0 prolene suture and underwent ex-vivo cyclic loading at 2-12 n in a sinusoidal wave for 100 cycles to simulate a passive range of motion (ROM) protocol. Subsequently, specimens were loaded to failure at 12 mm/minute. Gap formation and load to failure were measured. Results: No repair ruptures occurred during cyclical testing. Mean gap formation was 9.2 mm (±1.49) in the Bunnell repair, and 3.5 mm (±1.19) in the modified Bunnell repair (p < 0.0001). The mean load to failure for the Bunnell repair was 35.4 n compared to 45 n for the modified repair (p = 0.0017). Conclusions: Gap formation was reduced and load to failure increased by augmenting the Bunnell pull-out suture repair with the central portion of the DIP joint volar plate.
- 28 September 2022
- Published by World Scientific Pub Co Pte Ltd in The Journal of Hand Surgery (Asian-Pacific Volume)
- Vol. 27 (05) , 816-823
Cyclic Testing of a Modified Pull-Out Suture Repair Technique for Flexor Digitorum Profundus Avulsion in a Turkey Foot Model
Background: Numerous repair techniques have been described for closed flexor digitorum profundus (FDP) avulsion. One option is a pull-out suture tied over the nail plate (Bunnell repair). We modified the Bunnell repair by incorporating a portion of the distal interphalangeal (DIP) joint volar plate into the repair to improve strength and reduce gapping. The aim of this study is to compare gap formation and load to failure between the Bunnell repair and our modification in a turkey foot model. Methods: Twenty-four fresh-frozen cadaveric turkey feet were divided into two repair groups namely the conventional Bunnell pull-out suture technique and the modified Bunnell pull-out suture technique, incorporating the middle-third of the DIP joint volar plate into the repair. Both repairs were carried out with 3-0 prolene suture and underwent ex-vivo cyclic loading at 2-12 n in a sinusoidal wave for 100 cycles to simulate a passive range of motion (ROM) protocol. Subsequently, specimens were loaded to failure at 12 mm/minute. Gap formation and load to failure were measured. Results: No repair ruptures occurred during cyclical testing. Mean gap formation was 9.2 mm (±1.49) in the Bunnell repair, and 3.5 mm (±1.19) in the modified Bunnell repair (p < 0.0001). The mean load to failure for the Bunnell repair was 35.4 n compared to 45 n for the modified repair (p = 0.0017). Conclusions: Gap formation was reduced and load to failure increased by augmenting the Bunnell pull-out suture repair with the central portion of the DIP joint volar plate.
- 20 July 2009
- Published by SAGE Publications in Journal of Hand Surgery (European Volume)
- Vol. 35 (2) , 120-124
Lunate trabecular structure: a cadaveric radiograph study of risk factors for Kienböck's disease
The aetiology of Kienböck's disease is unknown. Ulnar variance and lunate shape are possible mechanical risk factors. This study assessed the trabecular structure in 29 cadaveric lunates using microCT and correlated this with ulnar variance and lunate shape on plain radiographs and with bone density assessed using conventional CT. The bony trabeculae within the lunate were shown to run almost perpendicular to the proximal and distal joint surfaces in the coronal plane; these trabeculae met the subchondral bone at an angle between 72–102°. In lunates whose proximal and distal articular surfaces are not parallel, the trabecular orientation may be less able to resist compressive forces and more susceptible to fracture.
- 20 July 2009
- Published by SAGE Publications in Journal of Hand Surgery (European Volume)
- Vol. 35 (2) , 120-124
Lunate trabecular structure: a cadaveric radiograph study of risk factors for Kienböck's disease
The aetiology of Kienböck's disease is unknown. Ulnar variance and lunate shape are possible mechanical risk factors. This study assessed the trabecular structure in 29 cadaveric lunates using microCT and correlated this with ulnar variance and lunate shape on plain radiographs and with bone density assessed using conventional CT. The bony trabeculae within the lunate were shown to run almost perpendicular to the proximal and distal joint surfaces in the coronal plane; these trabeculae met the subchondral bone at an angle between 72–102°. In lunates whose proximal and distal articular surfaces are not parallel, the trabecular orientation may be less able to resist compressive forces and more susceptible to fracture.