François Lestremau
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
François Lestremau has a total of 52 co-authors. Here are the top co-authors by number of shared publications:
Jérôme Beaumont
4 shared publications- Alexandre Albinet
Institut National de l’Environnement Industriel et des Risques (INERIS), Verneuil en Halatte, France
3 shared publications - Andrés Sauvêtre
Hydrosciences Montpellier, Univ Montpellier, IMT Mines Ales, IRD, CNRS, Ales, France
3 shared publications Camille Noblet
Institut National de l'Environnement Industriel et des Risques (INERIS), 60550 Verneuil en Halatte, France
3 shared publicationsClaudine Chatellier
Institut National de l'Environnement Industriel et des Risques (INERIS), 60550 Verneuil en Halatte, France
3 shared publications- Jean-Luc Besombes
Université Savoie Mont-Blanc, EDYTEM, 73000 Chambéry, France
3 shared publications
Latest Publications
- Open Access
- 18 September 2026
- Published by Elsevier in SSRN Electronic Journal
Development of an organic micropollutant extraction method for biofilm, compatible with LC-HRMS non-target analysis and in vitro bioassays
Wastewater (WW) monitoring remains challenging due to the matrix complexity and variability of contaminant mixtures. Among the different challenges, obtaining representative samples of micropollutants is particularly difficult using conventional grab and composite water sampling approaches. Biofilm-based passive samplers have emerged as a promising alternative, enabling time-integrated accumulation of contaminants and providing a more representative picture of WW contamination. However, the development of extraction procedures compatible with both comprehensive chemical analysis and in vitro bioassays remains a critical limitation. This study aimed to develop and optimize an extraction method for a biofilm-based passive sampler that enables the combined application of liquid chromatography–high-resolution mass spectrometry (LC-HRMS) and in vitro bioassays. Different extraction solvents, extraction techniques, and clean-up procedures were implemented. Method performance was assessed using complementary chemical and biological criteria, including extraction internal standard recoveries, suspect screening (SS) identifications, non-target screening (NTS) feature detection, and in vitro mechanism-based cellular bioassays targeting the aryl hydrocarbon, estrogen, and androgen receptors. Vortex extraction using acetonitrile:methanol (1:1, v/v) followed by dispersive solid-phase extraction using primary secondary amine was selected as the most optimized method, providing the best compromise between chemical coverage and bioassay responses. Such a protocol provides a common extraction method for biofilm-based passive samplers, yielding extracts compatible with both LC-HRMS screening and in vitro bioassays, thereby supporting complementary chemical and effect-based characterization of wastewater micropollutants.
- 18 September 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessDevelopment of an organic micropollutant extraction method for biofilm, compatible with LC-HRMS non-target analysis and in vitro bioassays
Wastewater (WW) monitoring remains challenging due to the matrix complexity and variability of contaminant mixtures. Among the different challenges, obtaining representative samples of micropollutants is particularly difficult using conventional grab and composite water sampling approaches. Biofilm-based passive samplers have emerged as a promising alternative, enabling time-integrated accumulation of contaminants and providing a more representative picture of WW contamination. However, the development of extraction procedures compatible with both comprehensive chemical analysis and in vitro bioassays remains a critical limitation. This study aimed to develop and optimize an extraction method for a biofilm-based passive sampler that enables the combined application of liquid chromatography–high-resolution mass spectrometry (LC-HRMS) and in vitro bioassays. Different extraction solvents, extraction techniques, and clean-up procedures were implemented. Method performance was assessed using complementary chemical and biological criteria, including extraction internal standard recoveries, suspect screening (SS) identifications, non-target screening (NTS) feature detection, and in vitro mechanism-based cellular bioassays targeting the aryl hydrocarbon, estrogen, and androgen receptors. Vortex extraction using acetonitrile:methanol (1:1, v/v) followed by dispersive solid-phase extraction using primary secondary amine was selected as the most optimized method, providing the best compromise between chemical coverage and bioassay responses. Such a protocol provides a common extraction method for biofilm-based passive samplers, yielding extracts compatible with both LC-HRMS screening and in vitro bioassays, thereby supporting complementary chemical and effect-based characterization of wastewater micropollutants.
- Open Access
- 18 September 2026
- Published by Elsevier in SSRN Electronic Journal
Rapid and simple extraction protocol for PFAS quantification in periphytic biofilms including short- and ultra-short-chain compounds
Per- and polyfluoroalkyl substances (PFAS) are widely distributed environmental contaminants of concern due to their persistence, toxicity, and bioaccumulation potential. Their structural diversity spans historical long‑chain compounds, next-generation alternatives (e.g., short-chain PFAS and polyfluorinated substances), and emerging molecules such as ultra-short chain (e.g. TFA), requiring analytical methods capable of capturing a broad range of targets. In parallel, periphytic biofilms have gained interest as biomonitoring tools for aquatic xenobiotics, including PFAS. Their ubiquity in aquatic ecosystems, combined with their structure and their capacity to sorb and accumulate contaminants, enables them to integrate PFAS exposure over time and potentially reveal contamination patterns that may not be captured through conventional water monitoring approaches. To support monitoring of a wide range of PFAS in such matrices, this article presents a rapid and simple extraction protocol adapted for periphytic biofilms. The method enables fast and reliable quantification of a wide range of PFAS including ultra-short chain compounds, using a small sample mass, limited reagent consumption and without cleaning step. The highlights of this method are: Applicable to a wide range of PFAS, including ultra-short-chain compounds in biofilm.Rapid and reliable extraction using minimal sample and reagents.No required cleaning step using SPE/dSPE.
- 18 September 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessRapid and simple extraction protocol for PFAS quantification in periphytic biofilms including short- and ultra-short-chain compounds
Per- and polyfluoroalkyl substances (PFAS) are widely distributed environmental contaminants of concern due to their persistence, toxicity, and bioaccumulation potential. Their structural diversity spans historical long‑chain compounds, next-generation alternatives (e.g., short-chain PFAS and polyfluorinated substances), and emerging molecules such as ultra-short chain (e.g. TFA), requiring analytical methods capable of capturing a broad range of targets. In parallel, periphytic biofilms have gained interest as biomonitoring tools for aquatic xenobiotics, including PFAS. Their ubiquity in aquatic ecosystems, combined with their structure and their capacity to sorb and accumulate contaminants, enables them to integrate PFAS exposure over time and potentially reveal contamination patterns that may not be captured through conventional water monitoring approaches. To support monitoring of a wide range of PFAS in such matrices, this article presents a rapid and simple extraction protocol adapted for periphytic biofilms. The method enables fast and reliable quantification of a wide range of PFAS including ultra-short chain compounds, using a small sample mass, limited reagent consumption and without cleaning step. The highlights of this method are: Applicable to a wide range of PFAS, including ultra-short-chain compounds in biofilm.Rapid and reliable extraction using minimal sample and reagents.No required cleaning step using SPE/dSPE.
- Open Access
Laccase–Biochar Synergy for Efficient Removal of Trimethoprim, Clindamycin, and Fipronil from Wastewater
The presence of organic micropollutants such as pharmaceuticals and pesticides in aquatic systems poses risks to environmental and public health, as conventional wastewater treatment plants are often ineffective at removing them, highlighting the need for alternative solutions. This study evaluates the combined use of biochar and laccase to remove trimethoprim, clindamycin, and fipronil, selected for their ubiquity, persistence, and physicochemical properties. Commercial wood-derived biochar was used, and removal performance was assessed through adsorption isotherms, time-dependent evaluation of removal efficiency, and quantification by UPLC-MS/MS. Toxicity after treatment was evaluated using bacterial growth assays with Escherichia coli and Rhodococcus erythropolis. Adsorption of trimethoprim and clindamycin followed the Langmuir model (Qmax 2.27 and 1.49 mg/g), while that of fipronil followed the Temkin model (Qmax 0.98 mg/g). The combined biochar–laccase system enabled up to 99% removal of trimethoprim and clindamycin within one hour, demonstrating synergy between adsorption and enzymatic removal. Enhanced removal was also observed for clindamycin and fipronil in mixtures. Bacterial assays showed partial restoration of growth after treatment, suggesting reduced antibacterial activity of transformation products, although effects remained species-dependent. Overall, the biochar–laccase system shows promise for micropollutant removal, supporting green remediation strategies, but further work is required to characterize transformation products and assess ecological impacts.
Open AccessLaccase–Biochar Synergy for Efficient Removal of Trimethoprim, Clindamycin, and Fipronil from Wastewater
The presence of organic micropollutants such as pharmaceuticals and pesticides in aquatic systems poses risks to environmental and public health, as conventional wastewater treatment plants are often ineffective at removing them, highlighting the need for alternative solutions. This study evaluates the combined use of biochar and laccase to remove trimethoprim, clindamycin, and fipronil, selected for their ubiquity, persistence, and physicochemical properties. Commercial wood-derived biochar was used, and removal performance was assessed through adsorption isotherms, time-dependent evaluation of removal efficiency, and quantification by UPLC-MS/MS. Toxicity after treatment was evaluated using bacterial growth assays with Escherichia coli and Rhodococcus erythropolis. Adsorption of trimethoprim and clindamycin followed the Langmuir model (Qmax 2.27 and 1.49 mg/g), while that of fipronil followed the Temkin model (Qmax 0.98 mg/g). The combined biochar–laccase system enabled up to 99% removal of trimethoprim and clindamycin within one hour, demonstrating synergy between adsorption and enzymatic removal. Enhanced removal was also observed for clindamycin and fipronil in mixtures. Bacterial assays showed partial restoration of growth after treatment, suggesting reduced antibacterial activity of transformation products, although effects remained species-dependent. Overall, the biochar–laccase system shows promise for micropollutant removal, supporting green remediation strategies, but further work is required to characterize transformation products and assess ecological impacts.
- 13 December 2025
- Published by Elsevier in Water Research
- Vol. 291, 125158
Optimizing electro-oxidation for selective trace micropollutant removal and energy efficiency in secondary effluents
- 13 December 2025
- Published by Elsevier in Water Research
- Vol. 291, 125158
Optimizing electro-oxidation for selective trace micropollutant removal and energy efficiency in secondary effluents
- Open Access
- 27 November 2025
- Published by Copernicus GmbH in Aerosol Research
- Vol. 3 (2) , 569-587
Differentiating between Euro 5 gasoline and diesel light-duty engine primary and secondary particle emissions using multivariate statistical analysis of high-resolution mass spectrometry (HRMS) fingerprints
Emissions from gasoline and diesel vehicles are predominant anthropogenic sources in ambient air, and their accurate source apportionment is a major concern for air quality policymakers aiming to implement effective strategies to reduce air pollution. Recent studies indicate that particulate matter (PM) emissions from modern cars equipped with the latest after-treatment technologies are mainly related to secondary organic aerosol (SOA) production, particularly in the case of gasoline vehicles. However, distinguishing between emissions from gasoline and diesel vehicles in ambient air remains challenging and is rarely achieved. This study aimed to evaluate the potential of non-targeted-screening (NTS) analyses for determining specific organic molecular markers of primary organic aerosol (POA) and SOA from gasoline and diesel vehicles, which could enhance PM source apportionment efforts. Experiments were conducted using a chassis dynamometer with Euro 5 gasoline and diesel vehicles under three different driving cycles. Exhaust emissions were diluted before being introduced into a potential aerosol mass oxidation flow reactor (PAM-OFR) to simulate atmospheric ageing and SOA formation. Samples were collected both upstream and downstream of the PAM-OFR and analysed using NTS approaches with liquid- and gas-chromatography coupled to quadrupole time-of-flight mass spectrometry (LC- and GC-QToF-MS). The chemical fingerprints obtained were compared using multivariate statistical analyses, including principal component analysis (PCA), hierarchical clustering analysis (HCA), and partial least-square discriminant analysis (PLS-DA). Results revealed specific fingerprints of POA and SOA for each type of vehicle tested and about 10 markers unique to each fraction of diesel and gasoline vehicles. This study demonstrates the promise of combining high-resolution mass-spectrometry-based NTS with advanced multivariate statistical analyses to differentiate between OA fingerprints and to discover specific markers of diesel and gasoline vehicular sources for further use in PM source apportionment studies.
- 27 November 2025
- Published by Copernicus GmbH in Aerosol Research
- Vol. 3 (2) , 569-587
Open AccessDifferentiating between Euro 5 gasoline and diesel light-duty engine primary and secondary particle emissions using multivariate statistical analysis of high-resolution mass spectrometry (HRMS) fingerprints
Emissions from gasoline and diesel vehicles are predominant anthropogenic sources in ambient air, and their accurate source apportionment is a major concern for air quality policymakers aiming to implement effective strategies to reduce air pollution. Recent studies indicate that particulate matter (PM) emissions from modern cars equipped with the latest after-treatment technologies are mainly related to secondary organic aerosol (SOA) production, particularly in the case of gasoline vehicles. However, distinguishing between emissions from gasoline and diesel vehicles in ambient air remains challenging and is rarely achieved. This study aimed to evaluate the potential of non-targeted-screening (NTS) analyses for determining specific organic molecular markers of primary organic aerosol (POA) and SOA from gasoline and diesel vehicles, which could enhance PM source apportionment efforts. Experiments were conducted using a chassis dynamometer with Euro 5 gasoline and diesel vehicles under three different driving cycles. Exhaust emissions were diluted before being introduced into a potential aerosol mass oxidation flow reactor (PAM-OFR) to simulate atmospheric ageing and SOA formation. Samples were collected both upstream and downstream of the PAM-OFR and analysed using NTS approaches with liquid- and gas-chromatography coupled to quadrupole time-of-flight mass spectrometry (LC- and GC-QToF-MS). The chemical fingerprints obtained were compared using multivariate statistical analyses, including principal component analysis (PCA), hierarchical clustering analysis (HCA), and partial least-square discriminant analysis (PLS-DA). Results revealed specific fingerprints of POA and SOA for each type of vehicle tested and about 10 markers unique to each fraction of diesel and gasoline vehicles. This study demonstrates the promise of combining high-resolution mass-spectrometry-based NTS with advanced multivariate statistical analyses to differentiate between OA fingerprints and to discover specific markers of diesel and gasoline vehicular sources for further use in PM source apportionment studies.
- Open Access
- 13 August 2025
- Published by Copernicus GmbH in EGUsphere
- Vol. 2025, 1-31
Discrimination of Euro 5 gasoline vs. Diesel light-duty engine primary and secondary particle emissions using multivariate statistical analysis of high-resolution mass spectrometry (HRMS) fingerprint
Emissions from gasoline and diesel vehicles are predominant anthropogenic sources in ambient air, and their accurate source apportionment is a major concern for air quality policymakers aiming to implement effective strategies to reduce air pollution. Recent studies indicate that particulate matter (PM) emissions from modern cars equipped with the latest after-treatment technologies are mainly related to secondary organic aerosol (SOA) production, particularly in the case of gasoline vehicles. However, distinguishing in ambient air between emissions from gasoline and Diesel vehicles remains challenging and is rarely achieved. This study aimed to evaluate the potential of non–targeted screening (NTS) analyses for determining specific organic molecular markers of primary organic aerosols (POA) and SOA from gasoline and Diesel vehicles, which could enhance PM source apportionment efforts. Experiments were conducted using a chassis dynamometer with Euro 5 gasoline and Diesel vehicles under three different driving cycles. Exhaust emissions were diluted before being introduced into a potential aerosol mass oxidation flow reactor (PAM-OFR) to simulate atmospheric aging and SOA formation. Samples were collected both upstream and downstream of the PAM-OFR and analysed using NTS approaches with liquid- and gas-chromatography coupled to quadrupole time-of-flight mass spectrometry (LC- and GC-QToF-MS). The chemical fingerprints obtained were compared using multivariate statistical analyses, including principal component analysis (PCA), hierarchical clustering analysis (HCA), and partial least square discriminant analysis (PLS-DA). Results revealed specific fingerprints of POA and SOA for each type of vehicle tested and about 10 markers unique to each fraction of Diesel and gasoline vehicles. This study demonstrates the promise of combining high-resolution mass spectrometry based NTS with advanced multivariate statistical analyses to differentiate OA fingerprints and discover specific markers of Diesel and gasoline vehicular sources for further use in PM source apportionment studies.
- 13 August 2025
- Published by Copernicus GmbH in EGUsphere
- Vol. 2025, 1-31
Open AccessDiscrimination of Euro 5 gasoline vs. Diesel light-duty engine primary and secondary particle emissions using multivariate statistical analysis of high-resolution mass spectrometry (HRMS) fingerprint
Emissions from gasoline and diesel vehicles are predominant anthropogenic sources in ambient air, and their accurate source apportionment is a major concern for air quality policymakers aiming to implement effective strategies to reduce air pollution. Recent studies indicate that particulate matter (PM) emissions from modern cars equipped with the latest after-treatment technologies are mainly related to secondary organic aerosol (SOA) production, particularly in the case of gasoline vehicles. However, distinguishing in ambient air between emissions from gasoline and Diesel vehicles remains challenging and is rarely achieved. This study aimed to evaluate the potential of non–targeted screening (NTS) analyses for determining specific organic molecular markers of primary organic aerosols (POA) and SOA from gasoline and Diesel vehicles, which could enhance PM source apportionment efforts. Experiments were conducted using a chassis dynamometer with Euro 5 gasoline and Diesel vehicles under three different driving cycles. Exhaust emissions were diluted before being introduced into a potential aerosol mass oxidation flow reactor (PAM-OFR) to simulate atmospheric aging and SOA formation. Samples were collected both upstream and downstream of the PAM-OFR and analysed using NTS approaches with liquid- and gas-chromatography coupled to quadrupole time-of-flight mass spectrometry (LC- and GC-QToF-MS). The chemical fingerprints obtained were compared using multivariate statistical analyses, including principal component analysis (PCA), hierarchical clustering analysis (HCA), and partial least square discriminant analysis (PLS-DA). Results revealed specific fingerprints of POA and SOA for each type of vehicle tested and about 10 markers unique to each fraction of Diesel and gasoline vehicles. This study demonstrates the promise of combining high-resolution mass spectrometry based NTS with advanced multivariate statistical analyses to differentiate OA fingerprints and discover specific markers of Diesel and gasoline vehicular sources for further use in PM source apportionment studies.
- Open Access
- 25 January 2024
- Published by Elsevier in Chemosphere
- Vol. 352, 141242
Aerosolomics based approach to discover source molecular markers: A case study for discriminating residential wood heating vs garden green waste burning emission sources
- 25 January 2024
- Published by Elsevier in Chemosphere
- Vol. 352, 141242
Open AccessAerosolomics based approach to discover source molecular markers: A case study for discriminating residential wood heating vs garden green waste burning emission sources
- 1 December 2014
- Published by Elsevier in Journal of Chromatography A
- Vol. 1372, 174-186
Towards a generic variable column length method development strategy for samples with a large variety in polarity
- 1 December 2014
- Published by Elsevier in Journal of Chromatography A
- Vol. 1372, 174-186
Towards a generic variable column length method development strategy for samples with a large variety in polarity