Kejiang Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kejiang Li has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Wuhui Chen
Taiyuan University of Technology
3 shared publications - Canbing Li
Shanghai Jiao Tong University
2 shared publications - Jing Qiu
The University of Sydney
2 shared publications Defu Liu
Xinjiang Control Center for Power Dispatching, State Grid Xinjiang Electrical Power Company Ltd., Wulumuqi, China
1 shared publication- Gengwu Zhang
School of Electrical and Power Engineering, Taiyuan University of Technology (Key Laboratory of Cleaner Intelligent Control on Coal & Electricity, Ministry of Education, Taiyuan, China
1 shared publication Hao Yu
Grid Planning and Research Center, Guangdong Grid Corporation, Guangzhou, Guangdong, China
1 shared publication
Latest Publications
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 17 (4) , 1-13
Risk Assessment of Forced SSO Excited by DFIG-Originated Interharmonics
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 17 (4) , 1-13
Risk Assessment of Forced SSO Excited by DFIG-Originated Interharmonics
- 26 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 40 (2) , 1570-1582
Analysis of Subsynchronous Oscillations Caused by Interactions of DFIG-Based Farms and SVGs
The static var generators (SVGs) installed at the point of common coupling (PCC) of wind farms can significantly impact the sub-synchronous oscillation (SSO) performance of the power system with grid-connected wind farms. For example, in 2017 multiple SSO events were caused by interactions among a doubly fed induction generator (DFIG) based farm, constant reactive power mode (CRPM) based SVGs, and the weak grid in Xinjiang, China. This paper reveals the mechanisms of the SSO caused by the interaction among DFIG-based farms, SVGs with different control modes, and weak grids. It is discovered that CRPM-based SVGs with low current controller bandwidths (CCBWs) can suppress SSOs in the power system with grid-connected DFIG-based farms, but that constant voltage mode (CVM) based SVGs and constant power factor mode (CPFM) based SVGs can worsen the SSO performance of the system. Furthermore, it is revealed why the amplitude of the super-synchronous component is larger than the sub-synchronous component in these events by deriving their amplitude ratio equation. Finally, the theoretical analysis results are verified by the small-signal method and electromagnetic transient (EMT) simulation.
- 26 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 40 (2) , 1570-1582
Analysis of Subsynchronous Oscillations Caused by Interactions of DFIG-Based Farms and SVGs
The static var generators (SVGs) installed at the point of common coupling (PCC) of wind farms can significantly impact the sub-synchronous oscillation (SSO) performance of the power system with grid-connected wind farms. For example, in 2017 multiple SSO events were caused by interactions among a doubly fed induction generator (DFIG) based farm, constant reactive power mode (CRPM) based SVGs, and the weak grid in Xinjiang, China. This paper reveals the mechanisms of the SSO caused by the interaction among DFIG-based farms, SVGs with different control modes, and weak grids. It is discovered that CRPM-based SVGs with low current controller bandwidths (CCBWs) can suppress SSOs in the power system with grid-connected DFIG-based farms, but that constant voltage mode (CVM) based SVGs and constant power factor mode (CPFM) based SVGs can worsen the SSO performance of the system. Furthermore, it is revealed why the amplitude of the super-synchronous component is larger than the sub-synchronous component in these events by deriving their amplitude ratio equation. Finally, the theoretical analysis results are verified by the small-signal method and electromagnetic transient (EMT) simulation.
- 3 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 39 (3) , 5416-5430
Forced Subsynchronous Oscillations of Turbine-Generators Excited by Interharmonics From Bundled Offshore Wind Farms
There is a potential risk of forced subsynchronous oscillations (FSSO) caused by interactions of turbine-generators and subsynchronous interharmonics (SSIH) from their bundled offshore wind farms (BOSWF). This article investigates the FSSO interactions of turbine-generators and SSIHs from the direct-drive permanent magnet synchronous generators (DPMSG) based BOSWF. Firstly, the switching function method is adopted to analyze the generation of SSIHs from the modulation between the active machine-side converter (MSC) and the grid-side converter (GSC) of DPMSGs. The three conditions where the severe FSSOs of turbine-generators are excited by the SSIHs from DPMSGs are obtained by use of a close-form solution of differential equations with forced terms. The three conditions are the coincidence between the complementary SSIH frequency and the torsional mode frequency of turbine-generators, the relatively weak damping of the torsional mode of turbine-generators, and the relatively large amplitude of SSIHs. It is revealed that the FSSOs are bounded. A severe FSSO of turbine-generators can be caused by the SSIHs from the DPMSG-based BOSWF, but its active power has no obvious subsynchronous oscillations (SSO) except the small-amplitude power disturbance because the mode frequencies of the BOSWFs are far away from the complementary SSIH frequencies. Finally, time-domain simulations verify the proposed theoretical analysis.
- 3 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 39 (3) , 5416-5430
Forced Subsynchronous Oscillations of Turbine-Generators Excited by Interharmonics From Bundled Offshore Wind Farms
There is a potential risk of forced subsynchronous oscillations (FSSO) caused by interactions of turbine-generators and subsynchronous interharmonics (SSIH) from their bundled offshore wind farms (BOSWF). This article investigates the FSSO interactions of turbine-generators and SSIHs from the direct-drive permanent magnet synchronous generators (DPMSG) based BOSWF. Firstly, the switching function method is adopted to analyze the generation of SSIHs from the modulation between the active machine-side converter (MSC) and the grid-side converter (GSC) of DPMSGs. The three conditions where the severe FSSOs of turbine-generators are excited by the SSIHs from DPMSGs are obtained by use of a close-form solution of differential equations with forced terms. The three conditions are the coincidence between the complementary SSIH frequency and the torsional mode frequency of turbine-generators, the relatively weak damping of the torsional mode of turbine-generators, and the relatively large amplitude of SSIHs. It is revealed that the FSSOs are bounded. A severe FSSO of turbine-generators can be caused by the SSIHs from the DPMSG-based BOSWF, but its active power has no obvious subsynchronous oscillations (SSO) except the small-amplitude power disturbance because the mode frequencies of the BOSWFs are far away from the complementary SSIH frequencies. Finally, time-domain simulations verify the proposed theoretical analysis.