A. Redey
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
A. Redey has a total of 70 co-authors. Here are the top co-authors by number of shared publications:
- H. Asch
Department of Physics, Simon Fraser University, Burnaby, BC, Canada
7 shared publications - Krzysztof Starosta
Simon Fraser University
7 shared publications K. van Wieren
5 shared publications- M. S. Martin
Simon Fraser University
5 shared publications - Z. Yu
Simon Fraser University
5 shared publications - A. Woinoski
Department of Physics, Simon Fraser University, Burnaby, BC, Canada
3 shared publications
Latest Publications
- Open Access
- 30 June 2026
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1092
Coupling of TIGRESS and EMMA with auxiliary array TIP at TRIUMF
- 30 June 2026
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1092
Open AccessCoupling of TIGRESS and EMMA with auxiliary array TIP at TRIUMF
- Open Access
- 24 November 2025
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1084
Novel application of the 8 π gamma-ray spectrometer for 3 γ positron emission tomography
- 24 November 2025
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1084
Open AccessNovel application of the 8 π gamma-ray spectrometer for 3 γ positron emission tomography
- 20 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (9) , 3102-3108
A Versatile Digital Data Acquisition System for the 8π Gamma-Ray Spectrometer
The 8π gamma-ray spectrometer is a highly-efficient and selective ball array of Bismuth Germanium Oxide (BGO) detectors. In 2014, it was relocated from TRIUMF, Canada’s particle accelerator centre, to the Simon Fraser University Nuclear Science Laboratory, where it has been recommissioned with upgraded components for rare decay spectroscopy. In its current configuration, 8π has 12 BGO pentagon detectors and 60 BGO hexagon detectors arranged in an icosahedral symmetry. Together, they provide 132 readout channels and approximately 95% solid-angle coverage. A unique digital Data Acquisition System (DAQ) has been developed around the existing 8π BGO detectors for the study of rare decays. This system allows for the fine-tuning of logic and digitization parameters through a web interface, eliminating the need for physical reconfiguration and providing a level of flexibility not previously offered. This upgraded DAQ system includes three synchronized VF48 digitizers for waveform digitization, two XLM72S modules for online multiplicity filtering, and additional components for thresholding and pile-up handling functionality. Performance metrics such as energy resolution, timing resolution, and efficiency were measured, demonstrating the functionality of all 8π subsystems. The spectrometer is fully prepared for experiments demanding efficient and selective time-resolved gamma-ray spectroscopy. Designed with future expansion in mind, the 8π can easily support additional detectors, making it well-suited for a wide range of future experiments.
- 20 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (9) , 3102-3108
A Versatile Digital Data Acquisition System for the 8π Gamma-Ray Spectrometer
The 8π gamma-ray spectrometer is a highly-efficient and selective ball array of Bismuth Germanium Oxide (BGO) detectors. In 2014, it was relocated from TRIUMF, Canada’s particle accelerator centre, to the Simon Fraser University Nuclear Science Laboratory, where it has been recommissioned with upgraded components for rare decay spectroscopy. In its current configuration, 8π has 12 BGO pentagon detectors and 60 BGO hexagon detectors arranged in an icosahedral symmetry. Together, they provide 132 readout channels and approximately 95% solid-angle coverage. A unique digital Data Acquisition System (DAQ) has been developed around the existing 8π BGO detectors for the study of rare decays. This system allows for the fine-tuning of logic and digitization parameters through a web interface, eliminating the need for physical reconfiguration and providing a level of flexibility not previously offered. This upgraded DAQ system includes three synchronized VF48 digitizers for waveform digitization, two XLM72S modules for online multiplicity filtering, and additional components for thresholding and pile-up handling functionality. Performance metrics such as energy resolution, timing resolution, and efficiency were measured, demonstrating the functionality of all 8π subsystems. The spectrometer is fully prepared for experiments demanding efficient and selective time-resolved gamma-ray spectroscopy. Designed with future expansion in mind, the 8π can easily support additional detectors, making it well-suited for a wide range of future experiments.
- Open Access
- 12 May 2025
- Published by Elsevier in Nuclear Physics A
- Vol. 1062
Mirror symmetry in the f7/2 shell below 56Ni, excited states and electromagnetic transition rates in 55Ni and 55Co
- 12 May 2025
- Published by Elsevier in Nuclear Physics A
- Vol. 1062
Open AccessMirror symmetry in the f7/2 shell below 56Ni, excited states and electromagnetic transition rates in 55Ni and 55Co
- 13 September 2024
- Published by American Physical Society (APS) in Physical Review C
- Vol. 110 (3)
measurements in the yrast band of : Implications for the island of inversion- 13 September 2024
- Published by American Physical Society (APS) in Physical Review C
- Vol. 110 (3)
measurements in the yrast band of : Implications for the island of inversion- 23 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (9) , 2162-2170
Direct Waveform Analysis of Ionization Chamber Signals for the SCI-CASTER Project
A prototype segmented ionization chamber and corresponding waveform analysis algorithm for the SCI-CASTER project at the Simon Fraser University Nuclear Science Laboratory is discussed in this work. Provided that a robust method of extracting data from the detector is implemented, segmented ionization chambers allow for measurement of both the energy and position of ionizing particles utilizing a single relatively inexpensive detector system. The waveform analyzer written for the SCI-CASTER project operates directly on raw digitized charge drift signals and generates a set of 7 piecewise functions which completely describe the input waveform. This reduces the storage and computation time needed to extract timings and amplitudes from the data, allowing for rapid and adaptive offline data analysis. Performance of the waveform analyzer is summarized for a set of experiment runs, and measurements of timing, energy, and a demonstration of the positional sensitivity of the prototype detector are given.
- 23 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (9) , 2162-2170
Direct Waveform Analysis of Ionization Chamber Signals for the SCI-CASTER Project
A prototype segmented ionization chamber and corresponding waveform analysis algorithm for the SCI-CASTER project at the Simon Fraser University Nuclear Science Laboratory is discussed in this work. Provided that a robust method of extracting data from the detector is implemented, segmented ionization chambers allow for measurement of both the energy and position of ionizing particles utilizing a single relatively inexpensive detector system. The waveform analyzer written for the SCI-CASTER project operates directly on raw digitized charge drift signals and generates a set of 7 piecewise functions which completely describe the input waveform. This reduces the storage and computation time needed to extract timings and amplitudes from the data, allowing for rapid and adaptive offline data analysis. Performance of the waveform analyzer is summarized for a set of experiment runs, and measurements of timing, energy, and a demonstration of the positional sensitivity of the prototype detector are given.
- 28 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (4) , 941-946
Versatile XLM72S Logic Module for Real-Time Event Filtering in Multidetector Systems: Implementation in Compton-Suppressed Gamma-Ray Spectroscopy
Detecting emitted radiation from nuclear processes such as reactions and radioactive decay allows for probes of the not-so-well understood nuclear interaction, a residual of the strong interaction which acts on quarks and gluons rather than protons and neutrons. Employing multi-detector systems as opposed to single-detector systems increases the breadth of studies which can be performed both by increasing the overall efficiency and by using time-correlated measurement techniques. With multi-detector systems, however, comes an increase in complexity, size, power consumption, and cost for data acquisition systems which can process and perform logical operations on raw signals. To combat this in the Nuclear Science Laboratory at Simon Fraser University, real-time event filtering has been implemented using a user programmable logic module called XLM72S. The logic module provides 72 emitter-coupled logic ports, configurable quartet-wise as inputs or outputs, an on-board 80 MHz clock, four digital clock managers capable of synthesizing additional clock frequencies, and two serial peripheral interface memories. In the current setup, the XLM72S allows for simultaneous and computer controlled logic to be performed on up to 20 Compton Suppressed Spectrometers used for the detection of gamma rays from nuclear decays, as well as up to 4 auxiliary signals used for filtering events which have coincident particle emission. The XLM72S module has been implemented and tested for a system containing five Compton Suppressed Spectrometers and a charged particle detector, demonstrating it’s effectiveness at performing logic in real time for anti-coincident Compton Suppression and coincidence multi-fold events.
- 28 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (4) , 941-946
Versatile XLM72S Logic Module for Real-Time Event Filtering in Multidetector Systems: Implementation in Compton-Suppressed Gamma-Ray Spectroscopy
Detecting emitted radiation from nuclear processes such as reactions and radioactive decay allows for probes of the not-so-well understood nuclear interaction, a residual of the strong interaction which acts on quarks and gluons rather than protons and neutrons. Employing multi-detector systems as opposed to single-detector systems increases the breadth of studies which can be performed both by increasing the overall efficiency and by using time-correlated measurement techniques. With multi-detector systems, however, comes an increase in complexity, size, power consumption, and cost for data acquisition systems which can process and perform logical operations on raw signals. To combat this in the Nuclear Science Laboratory at Simon Fraser University, real-time event filtering has been implemented using a user programmable logic module called XLM72S. The logic module provides 72 emitter-coupled logic ports, configurable quartet-wise as inputs or outputs, an on-board 80 MHz clock, four digital clock managers capable of synthesizing additional clock frequencies, and two serial peripheral interface memories. In the current setup, the XLM72S allows for simultaneous and computer controlled logic to be performed on up to 20 Compton Suppressed Spectrometers used for the detection of gamma rays from nuclear decays, as well as up to 4 auxiliary signals used for filtering events which have coincident particle emission. The XLM72S module has been implemented and tested for a system containing five Compton Suppressed Spectrometers and a charged particle detector, demonstrating it’s effectiveness at performing logic in real time for anti-coincident Compton Suppression and coincidence multi-fold events.