SWSaijie Wang

Saijie Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Saijie Wang has a total of 25 co-authors. Here are the top co-authors by number of shared publications:

  • Dou Wang

    Southern University of Science and Technology No. 1088 Xueyuan Road, Nanshan District

    5 shared publications
  • Xingyu Jiang

    Shenzhen Key Laboratory of Smart Healthcare Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Department of Biomedical Engineering Southern University of Science and Technology Shenzhen Guangdong P. R. China

    4 shared publications
  • Quanchen Xu

    Guangdong Provincial Key Laboratory of Advanced Biomaterials, Department of Biomedical Engineering, Southern University of Science and Technology, No. 1088 Xueyuan Rd, Nanshan District, Shenzhen, Guangdong 518055, China

    3 shared publications
  • Boxi Lu

    Guangdong Provincial Key Laboratory of Advanced Biomaterials, Shenzhen Key Laboratory of Smart Healthcare Engineering, Department of Biomedical Engineering, Southern University of Science and Technology, No. 1088 Xueyuan Road, Nanshan District, Shenzhen, Guangdong 518055, China

    2 shared publications
  • Qian Wang

    Guangdong Provincial Key Laboratory of Advanced Biomaterials, Department of Biomedical Engineering, Southern University of Science and Technology, No. 1088 Xueyuan Rd, Nanshan District, Shenzhen, Guangdong 518055, China

    2 shared publications
  • Yizhou Jiang

    Shenzhen Key Laboratory of Smart Healthcare Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Department of Biomedical Engineering, Southern University of Science and Technology, Shenzhen 518055, China

    2 shared publications

Latest Publications

  • Open Access

    A wearable device for continuous immunoassay-based monitoring of C-peptide in interstitial fluid

    by Shengbo Chen, Ziyu Guo, Boxi Lu, Mengsi Sun, Saijie Wang, Shunhang Li, Yizhou Jiang, Qiwu Wei, Dou Wang, Xingyu Jiang

    C-peptide is a critical biomarker for evaluating pancreatic β cell function and managing diabetes. However, conventional methods such as enzyme-linked immunosorbent assay are limited by lengthy processing times and the necessity for invasive sample collection. This study introduces a regenerable, portable, and wearable device for minimally invasive, real-time monitoring of C-peptide in dermal interstitial fluid (ISF). The device uses a microneedle array and negative pressure extraction for ISF collection. A double-antibody sandwich approach was used to detect C-peptide, and an antibody regeneration strategy was applied to remove bound antigen-antibody complexes, thereby achieving repeatable detection, enabling at least 10 detection assays on the same chip with negligible signal attenuation. The compact design features a skin contact area of only 3 cm by 5.4 cm and excellent biocompatibility. Integrated with a mobile app, the device provides real-time concentration reading. Mouse and rabbit tests confirm effective ISF sampling and monitoring accuracy, demonstrating its potential for at-home diabetes management and broader wearable biosensing applications.


  • Branch-convergence structure based on double-layer chip: a universal method for enhancing microfluidic mixing

    by Saijie Wang, Zhihan Zhang, Quanchen Xu, Yao Chen, Qian Wang, Boxi Lu, Xueqing Luo, Dou Wang, Xingyu Jiang

    Microfluidic mixing has significant applications in various fields, including materials synthesis and biochemical analysis. In this study, we propose a universal strategy to enhance mixing efficiency in microfluidic chips. This strategy initially divides the liquid into branches, which then converge in an interdigitated manner at the beginning of the mixing segment. This branch-convergence structure reduces the flow width of each liquid, thereby decreasing the diffusion distances required for mixing. Under the conditions of this study, the mixing efficiency could be improved by approximately 10 times. Importantly, this enhancement strategy only requires changing the structure of the liquid inflow channel without changing the structure of the mixing segment. Thus, this strategy has broad applicability, any mixing section with different principles and structures can be connected downstream of the branch-convergence structure. In addition, we applied this universal mixing enhancement strategy to the continuous synthesis of lactic-co-glycolic acid nanoparticles, resulting in a higher uniformity of synthesized nanoparticles compared to unenhanced devices.


  • Open Access

    Weakly ionized gold nanoparticles amplify immunoassays for ultrasensitive point-of-care sensors

    by Jiangjiang Zhang, Fengli Chai, Jia’an Li, Saijie Wang, Shuailong Zhang, Fenggang Li, Axin Liang, Aiqin Luo, Dou Wang, Xingyu Jiang

    Gold nanoparticle–based lateral flow immunoassays (AuNP LFIAs) are widely used point-of-care (POC) sensors for in vitro diagnostics. However, the sensitivity limitation of conventional AuNP LFIAs impedes the detection of trace biomarkers. Several studies have explored the size and shape factors of AuNPs and derivative nanohybrids, showing limited improvements or enhanced sensitivity at the cost of convenience and affordability. Here, we investigated surface chemistry on the sensitivity of AuNP LFIAs. By modifying surface ligands, a surface chemistry strategy involving weakly ionized AuNPs enables ultrasensitive naked-eye LFIAs (~100-fold enhanced sensitivity). We demonstrated how this surface chemistry–amplified immunoassay approach modulates nanointerfacial bindings to promote antibody adsorption and higher activity of adsorbed antibodies. This surface chemistry design eliminates complex nanosynthesis, auxiliary devices, or additional reagents while efficiently improving sensitivity with advantages: simplified fabrication process, excellent reproducibility and reliability, and ultrasensitivity toward various biomarkers. The surface chemistry using weakly ionized AuNPs represents a versatile approach for sensitizing POC sensors.


  • Open Access

    Biological particle separation techniques based on microfluidics

    by Saijie Wang, Quanchen Xu, Yanwei Cai, Qian Wang, Ying Liu, Dou Wang

    Biological particle separation has wide applications in medical diagnosis, bioengineering, and various other domains. Traditional methods, such as filtration, density gradient centrifugation, and size exclusion chromatography, face many challenges, including low separation resolution, low purity, and the inability to be seamlessly integrated into continuous processes. The development of microfluidics has paved the way for efficient and precise biological particle separation. Microfluidic chip‐based methods can generally be performed continuously and automatically, and microfluidic chips can integrate multilevel operations, including mixing, separation, detection, and so forth, thereby achieving continuous processing of particles at various levels. This review comprehensively investigates biological particle separation techniques based on microfluidic chips. According to the different sources of force effect on the particles during the separation process, they can be divided into active separation, passive separation, and affinity separation. We introduce the principles and device design of these methods respectively, and compare their advantages and disadvantages. For the introduction of each method, we used the most classic and latest research cases as much as possible. Additionally, we discussed the differences between experimental standard particles and biological particles. Finally, we summarized the current limitations and challenges of existing microfluidic separation techniques, while exploring future trends and prospects.


  • Reverse flow enhanced inertia pinched flow fractionation

    by Saijie Wang, Quanchen Xu, Zhihan Zhang, Shengbo Chen, Yizhou Jiang, Zhuowei Feng, Dou Wang, Xingyu Jiang

    By setting the reverse flow channel at the end of the abruptly broadened segment, the flow field can be fundamentally changed, and the separation performance can be improved comprehensively compared with the traditional iPFF device.