Federica Mazzoleni
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Federica Mazzoleni has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Carlotta Coppo
Oral Surgery School, IRCCS San Raffaele, Vita-Salute San Raffaele University, 20132 Milan, Italy
1 shared publication - Enrico Gherlone
Dental School, Vita-Salute San Raffaele University, IRCCS San Raffaele, 20132 Milan, Italy
1 shared publication - Francesco Ferrini
Dental School, Vita-Salute San Raffaele University, IRCCS San Raffaele Hospital, 20132 Milan, Italy
1 shared publication - Giovanna Laura Di Domenico
Dental Unit IRCCS San Raffaele Hospital Vita‐Salute San Raffaele University Milan Italy
1 shared publication - Matteo Barbini
Oral Surgery School, IRCCS San Raffaele, Vita-Salute San Raffaele University, 20132 Milan, Italy
1 shared publication
Latest Publications
- Open Access
- 22 April 2024
- Published by MDPI AG in Prosthesis
- Vol. 6 (2) , 401-412
Comparative Analysis of Intraoral Scanner Accuracy in a Six-Implant Complete-Arch Model: An In Vitro Study
(1) Background: Since new intraoral scanner (IOS) versions are introduced to the market and software continues to advance, there is an ongoing need to assess the accuracy of newer IOS models. (2) Methods: Four types of IOSs and one laboratory scanner (used as a reference) were used to scan an edentulous model with six parallel implants and their respective scan bodies, which were connected to each other. Using dedicated software, the distances between all scan bodies were calculated, generating a total of 540 measurements. Trueness (comparisons to the reference model) and precision (intragroup comparisons) were statistically compared with ANOVA and Tukey tests. (3) Results: When considering trueness values, statistically significant differences were observed between the tested scanner for all subgroups considered (p < 0.05). By contrast, no statistically significant differences were reported for precision values. (4) Conclusions: Within the limitations of the present in vitro study, it can be concluded that all tested IOSs were similar in terms of precision, while Trios and i700W yielded the worst trueness values. Nevertheless, increasing the measuring distance leads to a decrease in both trueness and precision.
- 22 April 2024
- Published by MDPI AG in Prosthesis
- Vol. 6 (2) , 401-412
Open AccessComparative Analysis of Intraoral Scanner Accuracy in a Six-Implant Complete-Arch Model: An In Vitro Study
(1) Background: Since new intraoral scanner (IOS) versions are introduced to the market and software continues to advance, there is an ongoing need to assess the accuracy of newer IOS models. (2) Methods: Four types of IOSs and one laboratory scanner (used as a reference) were used to scan an edentulous model with six parallel implants and their respective scan bodies, which were connected to each other. Using dedicated software, the distances between all scan bodies were calculated, generating a total of 540 measurements. Trueness (comparisons to the reference model) and precision (intragroup comparisons) were statistically compared with ANOVA and Tukey tests. (3) Results: When considering trueness values, statistically significant differences were observed between the tested scanner for all subgroups considered (p < 0.05). By contrast, no statistically significant differences were reported for precision values. (4) Conclusions: Within the limitations of the present in vitro study, it can be concluded that all tested IOSs were similar in terms of precision, while Trios and i700W yielded the worst trueness values. Nevertheless, increasing the measuring distance leads to a decrease in both trueness and precision.