NDNurullah Duger

Nurullah Duger

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Nurullah Duger has a total of 36 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Comparative Benchmark of Modern Deep Learning Backbones for Multi-Class Periodontal Bone Loss Staging

    by Nurullah Duger, Burak Dagtekin, Furkan Talo, Melek Atille Aydin, Mucahit Karaduman, Muhammed Yildirim, Tuba Talo Yildirim, Tolga Fikret Tozum

    Background/Objectives: Early diagnosis of periodontal disease is critical to prevent tissue destruction and tooth loss. This study evaluates six modern deep learning architectures for four-class radiographic periodontal bone loss grading on panoramic radiographs. Methods: This retrospective study analyzed 1053 images. Two periodontologists independently classified each image according to the most severely affected tooth into four bone loss categories: Healthy, Mild (50%). Six convolutional, transformer, and hybrid backbones (ConvNeXt-Tiny, MaxViT-Tiny, EfficientViT-B1, FocalNet-Tiny, CAFormer-S18, and DaViT-Tiny) were trained on a 70/10/20 stratified split using an NVIDIA Tesla T4 GPU, the AdamW optimizer, Cosine Annealing, and early stopping. Performance was assessed using standard classification metrics, Matthews Correlation Coefficient, Cohen’s and Quadratic Weighted Kappa, Expected Calibration Error, Area Under the Curve (AUC), McNemar’s test, and bootstrap 95% confidence intervals. Results: FocalNet-Tiny achieved the highest numerical scores among the tested models, reaching 83.41% accuracy, 84.70% balanced accuracy, 83.50% macro-F1, and 0.9610 OvR AUC. The p-values obtained from the comparisons of the models were all above 0.05, indicating that the classification performances of the evaluated models are quite similar. Bootstrap analysis confirmed stable prediction metrics for the top-scoring model. Conclusions: This study provides a controlled benchmark of modern deep learning backbones for four-class radiographic periodontal bone loss grading. FocalNet-Tiny achieved the highest numerical metrics and stable bootstrap estimates, yet performed comparably to other contemporary architectures such as ConvNeXt-Tiny. Direct radiographic classification shows promise for automated radiographic pre-screening; however, multi-center external validation and integration with clinical periodontal parameters are required before clinical implementation.

  • Feature-Level Fusion–Based CNN–Transformer–KAN Hybrid Approach for Dental Implant Diameter and Length Detection

    by Furkan Talo, Mucahit Karaduman, Nurullah Duger, Gulsah Karaduman, Muhammed Yildirim, Melek Atille Aydin, Gulucag Giray Tekin, Tuba Talo Yildirim

  • Open Access

    Automatic Detection of Sinus Membrane Thickness Using a Hybrid Deep Learning Model Integrating Multiple Attention Mechanisms

    by Furkan Talo, Nurullah Duger, Burak Dagtekin, Mucahit Karaduman, Muhammed Yildirim, Tuba Talo Yildirim

    Background/Objectives: In dental implant surgeries, automatic detection and classification of maxillary sinus membrane thickening from Cone-Beam Computed Tomography (CBCT) images used for diagnosis and treatment planning, using an artificial intelligence-based system, will both reduce specialists’ error rates and enable faster processing. Therefore, in this study, a unique model was developed to automatically detect maxillary sinus membrane thickening from CBCT images. Methods: The first step of the developed model is data preprocessing. Then, feature extraction is performed using the backbone Convolutional Neural Network (CNN). The obtained features are processed in parallel with Squeeze-and-Excitation (SE), Convolutional Block Attention Module (CBAM), and Efficient Channel Attention (ECA) attention mechanisms. In this stage, channel, spatial, and local relationships are better represented. The combined features are passed to a Multilayer Perceptron (MLP) with dropout to mitigate overlearning, and the final class estimation is performed by a softmax layer. Results: Thanks to the attention mechanisms employed in the developed hybrid model, both the model’s representational power and its classification performance have improved. The model developed to automatically detect and classify maxillary sinus membrane thickening from CBCT images achieved a test accuracy rate of 99.43%. Conclusions: The developed model was compared with pre-trained models accepted in the literature and demonstrated superior performance. The current results demonstrate that the proposed model exhibits high performance in classifying maxillary sinus membrane thickness in a single-center CBCT dataset. However, independent external validation and prospective clinical evaluation are necessary to determine its potential for clinical use.

  • Open Access

    An Attention-Enhanced RegNetY Framework for Detection and Classification of Vertical Misfit in Implant-Supported Restorations: A Retrospective Study

    by Tuba Talo Yildirim, Aybike Cengiz Dagtekin, Nurullah Düger, Ayşe Rençber Kizilkaya, Furkan Talo, Emre Arslan, Mucahit Karaduman, Muhammed Yildirim

    Background/Objectives: The aim of this study is to test different convolutional neural network (CNN) and Transformer-based models to detect and classify vertical misfit at the abutment-prosthesis interface on panoramic radiographs, and to develop a hybrid deep learning model enhanced with attention mechanisms. Methods: A dataset consisting of a total of 566 images, manually classified as 249 ‘fit’ and 317 ‘misfit’ cases by two experts, was created. Images were resized to 224 × 224 and divided into training, validation, and test groups. The deep learning model yielding the most successful results was determined as the backbone; a hybrid model was developed by integrating three different attention modules (SE, CBAM, and ECA) into this structure. Model performance was evaluated using accuracy, precision, sensitivity, and F1 score metrics. Results: CNN-based models (RegNetY-800MF, ConvNeXt-Tiny, EfficientNetV2-S, ResNet50) performed better than Transformer-based models (DeiT, Swin-Tiny) in all metrics. The proposed hybrid model exhibited the highest success among all tested models with a 99.12% accuracy rate. This model reached a 100% precision value in the misfit group and yielded no false positive results. The F1 scores of the hybrid model were recorded as 99.01% for the fit group and 99.21% for the misfit group. Conclusions: The findings of this study demonstrate that attention-enhancing deep learning frameworks have the potential to significantly improve the diagnostic utility of routine panoramic radiographs. It shows that panoramic imaging, when supported by advanced artificial intelligence, can provide valuable diagnostic support in detecting vertical misfit. The developed model has the potential to become a reliable clinical decision support system.


  • Open Access

    Automated Classification of Maxillary Sinus Ostium Patency Using a ConvNeXt-Tiny + DeiT Gated MLP-Based Hybrid Deep Learning Model: A Retrospective CBCT Study

    by Furkan Talo, Nurullah Duger, Emre Aslan, Muhammed Yildirim, Mahmut Kaya, Ahmet Bedri Ozer, Tuba Talo Yildirim

    Background/Objectives: The patency and anatomical location of the maxillary sinus ostium are critical for preventing postoperative complications in dental implant planning and sinus lift surgeries in the posterior maxilla. Narrowing or obstruction of the ostium carries risks, including the development of acute/chronic sinusitis and bone graft failure after surgery. These risks must be carefully evaluated using preoperative radiographic images. It is time-consuming for physicians to manually perform this process, and details are overlooked due to a lack of clinical experience, which can increase surgical risks. Methods: This study aims to overcome these clinical challenges and improve the reliability of radiographic evaluation. In this study, a hybrid deep learning model is proposed for the automatic detection of the maxillary sinus ostium. The proposed model combines the local feature extraction power of CNN-based models with the global context modeling capabilities of transformer-based models, creating an effective model. Additionally, the gated fusion technique efficiently combines features from various designs, significantly enhancing classification performance. Results: The proposed model was compared with six different ViT and CNN architectures established in the literature. While the highest test accuracy among pre-trained models was 89.36%, the proposed hybrid model achieved 95.03%, demonstrating strong clinical diagnostic performance. Conclusions: Based on the performance metrics obtained, we believe the proposed model can be used to determine the patency of the maxillary sinus ostium. This will lighten the workload for specialists and minimize traditional errors.

  • Automatic Detection of Dental Implant Brands Using a Hybrid Vision Transformer-Based Deep Learning Model

    by Ayşe Rençber Kızılkaya, Mucahit Karaduman, Harun Kurt, Tuba Talo Yıldırım, Nurullah Düger, Furkan Talo, Muhammed Yıldırım

    Dental implants are commonly used to restore the function and esthetics of missing teeth, and their long-term success depends on appropriate maintenance and follow-up interventions. One of the major clinical challenges is clinicians’ inability to identify the brand of a patient’s previously placed implants, which complicates the selection of compatible prosthetic components and instruments for subsequent treatments. This study aimed to develop a deep learning–based approach to identify dental implant brands automatically. A hybrid model based on Vision Transformer (ViT) architectures was proposed. To enhance efficiency, feature maps from three state-of-the-art ViT models were integrated and then classified with multiple classifiers. The proposed model achieved an accuracy of 87.92%, outperforming widely used benchmark methods in the literature. These findings demonstrate the proposed model's potential to help clinicians accurately identify implant brands, thereby facilitating appropriate prosthetic procedures and improving clinical workflow.


  • Open Access

    Evaluation of Maxillary Sinus Membrane Morphology Using a Novel Hybrid CNN-ViT-Based Deep Learning Model: An Automated Classification Study

    by Nurullah Duger, Furkan Talo, Gulucag Giray Tekin, Burak Dagtekin, Mucahit Karaduman, Muhammed Yildirim, Tuba Talo Yildirim

    Objectives: This study aimed to develop and validate a hybrid deep learning model combining Convolutional Neural Networks (CNN) and Vision Transformers (ViT) to automatically classify maxillary sinus membrane morphologies on Cone-Beam Computed Tomography (CBCT) images, distinguishing between Normal, Flat, Polypoid, and Obstruction types. Methods: A dataset of 959 CBCT images was collected and categorized into four morphological classes: Normal, Flat, Polypoid and Obstruction. A custom hybrid model was developed, integrating a lightweight residual CNN for local feature extraction, learnable weighted feature fusion with a bidirectional feature pyramid network and a Transformer encoder for global context modeling. The performance of proposed model was compared against six different architectures, including ResNet50, MobileNetV3L and standard ViT models, using accuracy, precision, recall and F1-score metrics. Results: The proposed hybrid model achieved the highest overall accuracy of 98.44%, outperforming six strong CNN and ViT models including ResNet50 (97.92%) and ViT-B16 (86.46%) models. In class-wise analysis, the model demonstrated superior diagnostic capability, particularly for the “Obstruction” class, achieving 100% accuracy. High discrimination was also observed for “Flat” (98.21%) and “Polypoid” (98.04%) morphologies, confirming the model’s sensitivity to shape-based features. Conclusions: The proposed hybrid CNN-ViT model successfully classifies maxillary sinus membrane morphologies with high accuracy, effectively overcoming the limitations of standard ViT models on limited datasets. Detection of membrane morphology is vital for predicting surgical risks like membrane perforation and post-operative sinusitis. This model serves as a reliable clinical decision support tool, enabling clinicians to objectively assess specific risk factors before implant surgery and sinus floor elevation.


  • Open Access

    Direct Relationship Between Heparin Binding to Midkine and Pleiotrophin and the Development of Acute Deep Vein Thrombosis

    by Suna Aydin, İsmail Polat, Kevser Tural, Nurullah Duger, Kader Ugur, İbrahim Sahin, Suleyman Aydin, Do-Youn Lee

    Background/Objectives: The underlying molecular mechanisms of deep vein thrombosis (DVT), which continues to be a major global public health concern, remain unclear. A key component of anticoagulant therapy, heparin (HP) interacts with heparin-binding growth factors including pleiotrophin (PTN) and midkine (MK), both of which have basic amino acid-rich domains that have a strong affinity for HP. The purpose of this study was to determine if changes in the levels of circulating HP, MK, and PTN are linked to the onset of acute DVT. Methods: Thirty patients diagnosed with acute DVT by venous Doppler ultrasonography (VDU) and 28 healthy controls with normal VDU findings were enrolled. Serum HP, MK, and PTN concentrations were measured using ELISA. In DVT patients, blood samples were obtained before and after routine subcutaneous low-molecular-weight heparin treatment; controls provided a single blood sample. ROC curve analysis was used to assess diagnostic performance. Results: Prior to treatment, patients with acute DVT exhibited significantly lower serum HP levels (p < 0.05) and significantly higher MK and PTN levels compared with healthy controls (both p < 0.05). Following heparin administration, serum HP levels increased significantly (p < 0.05), while MK and PTN levels showed a decreasing trend that did not reach statistical significance (p > 0.05). ROC curve analysis demonstrated limited diagnostic performance for HP (sensitivity 10.3%, specificity 68.8%), PTN (62.1%, 54.2%), and MK (82.8%, 35.4%). Conclusions: Decreased circulating HP and increased MK and PTN levels are characteristics of acute DVT that may indicate endogenous HP sequestration through binding to these growth factors. This imbalance could lead to less free HP being available, which would encourage the formation of thrombus. Therapeutic approaches that target MK- and PTN-mediated HP interactions may constitute a unique approach for the therapy of acute DVT, as evidenced by the partial normalization seen after exogenous heparin delivery.


  • Open Access

    Biomechanical investigation of the effect of Vitamin C supplementation on Osseointegration of titanium implants in rat (Rattus norvegicus) tibia

    by Can Ayhan Kaya, Murat Tanrisever, Nurullah Duger, Tuba Talo Yildirim, Erhan Cahit Ozcan, Umit Koray Can, Turker Gelic, Alihan Bozoglan, Serkan Dundar

    In this study, it was aimed to evaluate some possible effects of vitamin C supplementation on the osseointegration process implants placed in rat tibias. Thirty 3-month-old female Spraque Dawley rats (Rattus norvegicus) were divided into 3 groups. In all groups, the corticocancellous part of the the metaphysis of the right tibia bones were surgically reached. Monocortical implant sockets were created by surgical methods under serum cooling, and then titanium implants with 2.5 mm diameter and 4 mm long titanium were integrated on these bone sockets. Group Sham (Control) (n=10): No additional application was made during the experimental process. Group C1 (n=10): 5 mg/kg vitamin C was given to the rats with oral gavage application in three days a week for four weeks of experimental process. Group C2 (n=10): 10 mg/kg vitamin C was given to the rats with oral gavage application in three days a week for four weeks of experimental process. At the end of the four- week experimental setup, all rats were sacrificed and the experimental process was completed. The implants integrated in the tibias of all rats were collected with the surrounding bone tissue after removing the soft tissues for biomechanical analysis. Biomechanical reverse torque analysis was applied to all implants. Statistical analysis of the obtained data; Kruskall- Wallis test, no statistically significant difference was detected between the control and experimental groups (P>0,05). In conclusion, 5 and 10mg/kg vitamin C supplementation has no positive or negative effects on osseointegration. This situaiton can be explained in two ways; the first, the dosages of vitamin C used in this study is not sufficient to create an effect. Second, the endogenous synthesis of this vitamin is enough even though under these stress conditions.

  • Open Access

    Evaluation of the behavior and health anxiety levels the patients applying to the periodontology clinic during the COVID-19 pandemic

    by Dicle Altindal, Filiz Acun Kaya, Tuba Talo Yildirim, Ersin Uysal, Nurullah Duger

    Background: The aim of this study was to examine the general behavioral status of individuals who applied to a periodontology clinic during the COVID-19 pandemic to evaluate their health anxiety levels and to compare their anxiety score averages in terms of various factors. Methods: This study was carried out using the face-to-face survey method. Participants were asked to fill out a demographic data form, a survey form asking about pandemic-related behaviors, and the Short Health Anxiety Inventory (SHAI). The effects of factors such as age, gender, marital status, educational status, working in a health institution, and having had COVID-19 disease on health anxiety levels were investigated. The Kolmogorov-Smirnov test, Shapiro-Wilk test, independent samples t test, ANOVA, and Tukey’s HSD test were used for statistical analysis (P<0.05). Results: A total of 400 volunteer participants were included (252 females and 148 males). Anxiety score averages showed a statistically significant difference in terms of gender and education (P=0.023 and P=0.001, respectively). Accordingly, the females’ mean SHAI score (17.45±7.053) was found to be higher than the males’ (15.69±8.161). The mean SHAI scores of primary school graduates (20.86±6.105) were higher than those of high school (15.95±8.197) and university graduates (16.11±6.367). There was no significant difference in terms of marital status, working in a health institution, and being diagnosed with COVID-19. Also, 48.2% of the participants only used surgical masks. Conclusion: Most participants declared that their confidence in healthcare workers increased during the epidemic. Females and individuals with low educational status had higher health anxiety in this study.