Young-Sun Park
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Young-Sun Park has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Joong Min Lee
Division of Cardiology, Heart Institute, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea (J.-M.A., D.-Y.K., S.-B.W., J.M.L., Y.-S.P., J.H.K., D.-W.P., S.-J.P.).
3 shared publications - Do-Yoon Kang
Department of Cardiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
2 shared publications - Duk-Woo Park
Department of Cardiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
2 shared publications - Ha Hye Jo
Department of Cardiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
2 shared publications - Hwa Jung Kim
Department of Clinical Epidemiology and Biostatistics, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
2 shared publications - Jung-Min Ahn
Department of Cardiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
2 shared publications
Latest Publications
- Open Access
- 1 January 2027
- Published by XMLink in Korean Circulation Journal
- Vol. 57
Atrial Fibrillation/Flutter After Transcatheter Device vs. Surgical Closure of Atrial Septal Defect in a Korean Nationwide Cohort
Lee JM, et al. Korean Circ J. 2027 ;57:e11. https://doi.org/10.4070/kcj.2025.0487
- 1 January 2027
- Published by XMLink in Korean Circulation Journal
- Vol. 57
Open AccessAtrial Fibrillation/Flutter After Transcatheter Device vs. Surgical Closure of Atrial Septal Defect in a Korean Nationwide Cohort
Lee JM, et al. Korean Circ J. 2027 ;57:e11. https://doi.org/10.4070/kcj.2025.0487
- 24 September 2026
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Interventions
Contrasting Prognostic Value of Discordance Between Resting Distal-to-Aortic Coronary Pressure Ratio and Fractional Flow Reserve in Coronary Artery Disease
BACKGROUND: Discordance between nonhyperemic pressure ratios and fractional flow reserve (FFR), observed in up to 20% of cases, complicates clinical decision-making for coronary revascularization and warrants further investigation of its clinical implications. This study aimed to evaluate the outcomes of medically managed discordant lesions between FFR and the resting whole-cycle distal-to-aortic coronary pressure ratio (Pd/Pa). METHODS: From the prospective IRIS-FFR registry (Interventional Cardiology Research In-Cooperation Society Fractional Flow Reserve), 9737 lesions in 7376 patients treated medically were analyzed. The lesions were grouped based on resting Pd/Pa (≤0.93) and FFR (≤0.80) values. The primary outcome was 5-year target-vessel failure, including target-vessel myocardial infarction and target-vessel revascularization, with death from any cause considered as a competing risk. The key secondary outcome was death from any cause. RESULTS: Discordance between resting Pd/Pa and FFR was present in 15.91% of lesions treated medically (n=1549). Lesions with resting Pd/Pa >0.93 and FFR ≤0.80 had a higher risk of target-vessel failure than those with resting Pd/Pa ≤0.93 and FFR >0.80 (adjusted hazard ratio, 1.67 [95% CI, 1.09–2.55]; P =0.020) but a lower risk of all-cause death (adjusted hazard ratio, 0.23 [95% CI, 0.11–0.52]; P 0.93 and FFR ≤0.80. CONCLUSIONS: FFR predicts vessel-specific coronary events, whereas resting Pd/Pa is associated with overall survival. The contrasting prognostic value of discordant lesions underscores the clinical importance of a complementary assessment using both resting and hyperemic coronary physiological indices. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT01366404.
- 24 September 2026
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Interventions
Contrasting Prognostic Value of Discordance Between Resting Distal-to-Aortic Coronary Pressure Ratio and Fractional Flow Reserve in Coronary Artery Disease
BACKGROUND: Discordance between nonhyperemic pressure ratios and fractional flow reserve (FFR), observed in up to 20% of cases, complicates clinical decision-making for coronary revascularization and warrants further investigation of its clinical implications. This study aimed to evaluate the outcomes of medically managed discordant lesions between FFR and the resting whole-cycle distal-to-aortic coronary pressure ratio (Pd/Pa). METHODS: From the prospective IRIS-FFR registry (Interventional Cardiology Research In-Cooperation Society Fractional Flow Reserve), 9737 lesions in 7376 patients treated medically were analyzed. The lesions were grouped based on resting Pd/Pa (≤0.93) and FFR (≤0.80) values. The primary outcome was 5-year target-vessel failure, including target-vessel myocardial infarction and target-vessel revascularization, with death from any cause considered as a competing risk. The key secondary outcome was death from any cause. RESULTS: Discordance between resting Pd/Pa and FFR was present in 15.91% of lesions treated medically (n=1549). Lesions with resting Pd/Pa >0.93 and FFR ≤0.80 had a higher risk of target-vessel failure than those with resting Pd/Pa ≤0.93 and FFR >0.80 (adjusted hazard ratio, 1.67 [95% CI, 1.09–2.55]; P =0.020) but a lower risk of all-cause death (adjusted hazard ratio, 0.23 [95% CI, 0.11–0.52]; P 0.93 and FFR ≤0.80. CONCLUSIONS: FFR predicts vessel-specific coronary events, whereas resting Pd/Pa is associated with overall survival. The contrasting prognostic value of discordant lesions underscores the clinical importance of a complementary assessment using both resting and hyperemic coronary physiological indices. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT01366404.
- Open Access
- 20 February 2026
- Published by Wolters Kluwer Health in Medicine
- Vol. 105 (8) , e47739
Comparison of the burden of ventricular arrhythmias before and after left ventricular assist device implantation: A retrospective observational study
Ventricular arrhythmias (VAs) are frequently observed in patients awaiting or who have already undergone left ventricular assist device (LVAD) implantation. However, the impact of LVAD implantation on the burden of VAs and the prognostic significance of postoperative VAs remain unclear. Between June 2015 and July 2024, 108 patients who underwent LVAD implantation were retrospectively analyzed. The burden of VAs was defined as the total number of documented VAs or implantable cardioverter-defibrillator therapies, including anti-tachycardia pacing and appropriate shocks. The incidence and burden of VAs before and after LVAD implantation were compared, and factors associated with postoperative VAs were evaluated using multivariable regression analysis. Among the 108 patients who successfully underwent LVAD implantation, the prevalence of VAs decreased after implantation (39.8% [n = 43] vs 25.9% [n = 28], P < .01). However, there was no significant difference in the burden of VAs before and after LVAD implantation (4.30 ± 31.42 vs 2.89 ± 13.11 events/mo, P = .50). The incidence of VAs, anti-tachycardia pacing, and appropriate shocks did not significantly decrease after LVAD implantation (2.34 ± 16.89 vs 2.26 ± 13.04, P = .26; 1.22 ± 7.68 vs 0.91 ± 5.82, P = .58; and 0.88 ± 7.24 vs 0.28 ± 1.29, P = .21, respectively). Multivariable regression analysis showed that only preoperative VAs were associated with postoperative VAs (hazard ratio 15.6 [95% confidence interval, 3.70–64.49]; P < .01). There was no significant difference in survival according to the occurrence of postoperative VAs ( P = .94). LVAD implantation does not reduce the burden of VAs. A history of preoperative VAs remains a strong risk factor for postoperative VAs. However, even if VAs occurred after LVAD implantation, the mortality risk did not increase.
- 20 February 2026
- Published by Wolters Kluwer Health in Medicine
- Vol. 105 (8) , e47739
Open AccessComparison of the burden of ventricular arrhythmias before and after left ventricular assist device implantation: A retrospective observational study
Ventricular arrhythmias (VAs) are frequently observed in patients awaiting or who have already undergone left ventricular assist device (LVAD) implantation. However, the impact of LVAD implantation on the burden of VAs and the prognostic significance of postoperative VAs remain unclear. Between June 2015 and July 2024, 108 patients who underwent LVAD implantation were retrospectively analyzed. The burden of VAs was defined as the total number of documented VAs or implantable cardioverter-defibrillator therapies, including anti-tachycardia pacing and appropriate shocks. The incidence and burden of VAs before and after LVAD implantation were compared, and factors associated with postoperative VAs were evaluated using multivariable regression analysis. Among the 108 patients who successfully underwent LVAD implantation, the prevalence of VAs decreased after implantation (39.8% [n = 43] vs 25.9% [n = 28], P < .01). However, there was no significant difference in the burden of VAs before and after LVAD implantation (4.30 ± 31.42 vs 2.89 ± 13.11 events/mo, P = .50). The incidence of VAs, anti-tachycardia pacing, and appropriate shocks did not significantly decrease after LVAD implantation (2.34 ± 16.89 vs 2.26 ± 13.04, P = .26; 1.22 ± 7.68 vs 0.91 ± 5.82, P = .58; and 0.88 ± 7.24 vs 0.28 ± 1.29, P = .21, respectively). Multivariable regression analysis showed that only preoperative VAs were associated with postoperative VAs (hazard ratio 15.6 [95% confidence interval, 3.70–64.49]; P < .01). There was no significant difference in survival according to the occurrence of postoperative VAs ( P = .94). LVAD implantation does not reduce the burden of VAs. A history of preoperative VAs remains a strong risk factor for postoperative VAs. However, even if VAs occurred after LVAD implantation, the mortality risk did not increase.
- 1 May 2024
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Interventions
- Vol. 17 (5) , e013237
Evaluation of Instantaneous Wave-Free Ratio and Fractional Flow Reserve in Severe Aortic Valve Stenosis
BACKGROUND: The optimal functional evaluation of coronary artery stenosis in patients with severe aortic stenosis (AS) has not been established. The objective of the study was to evaluate the instantaneous wave-free ratio (iFR) and fractional flow reserve (FFR) in patients with and without severe AS. METHODS: We retrospectively investigated 395 lesions in 293 patients with severe AS and 2257 lesions in 1882 patients without severe AS between 2010 and 2022 from a subgroup of the Interventional Cardiology Research In-Cooperation Society FFR Registry. All patients had FFR values, and iFR was analyzed post hoc using dedicated software only in lesions with adequate resting pressure curves (311 lesions in patients with severe AS and 2257 lesions in patients with nonsevere AS). RESULTS: The incidence of iFR ≤0.89 was 66.6% and 31.8% ( P 0.89 had FFR >0.80, while 36.2% of lesions with iFR ≤0.89 had FFR >0.80. During a median follow-up of 2 years, FFR ≤0.80 was significantly associated with deferred lesion failure (adjusted hazard ratio, 2.71 [95% CI, 1.08–6.80]; P =0.034), while iFR ≤0.89 showed no prognostic value (adjusted hazard ratio, 1.31 [95% CI, 0.47–3.60]; P =0.60) in the severe AS group. Lesions with iFR ≤0.89 and FFR >0.80, in particular, were not associated with a higher rate of deferred lesion failure at 3 years compared with lesions with iFR >0.89 (15.4% versus 17.0%; P =0.58). CONCLUSIONS: This study suggested that FFR appears to be less affected by the presence of severe AS and is more associated with prognosis. iFR may overestimate the functional severity of coronary artery disease without prognostic significance, yet it can be useful for excluding significant stenosis in patients with severe AS.
- 1 May 2024
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Interventions
- Vol. 17 (5) , e013237
Evaluation of Instantaneous Wave-Free Ratio and Fractional Flow Reserve in Severe Aortic Valve Stenosis
BACKGROUND: The optimal functional evaluation of coronary artery stenosis in patients with severe aortic stenosis (AS) has not been established. The objective of the study was to evaluate the instantaneous wave-free ratio (iFR) and fractional flow reserve (FFR) in patients with and without severe AS. METHODS: We retrospectively investigated 395 lesions in 293 patients with severe AS and 2257 lesions in 1882 patients without severe AS between 2010 and 2022 from a subgroup of the Interventional Cardiology Research In-Cooperation Society FFR Registry. All patients had FFR values, and iFR was analyzed post hoc using dedicated software only in lesions with adequate resting pressure curves (311 lesions in patients with severe AS and 2257 lesions in patients with nonsevere AS). RESULTS: The incidence of iFR ≤0.89 was 66.6% and 31.8% ( P 0.89 had FFR >0.80, while 36.2% of lesions with iFR ≤0.89 had FFR >0.80. During a median follow-up of 2 years, FFR ≤0.80 was significantly associated with deferred lesion failure (adjusted hazard ratio, 2.71 [95% CI, 1.08–6.80]; P =0.034), while iFR ≤0.89 showed no prognostic value (adjusted hazard ratio, 1.31 [95% CI, 0.47–3.60]; P =0.60) in the severe AS group. Lesions with iFR ≤0.89 and FFR >0.80, in particular, were not associated with a higher rate of deferred lesion failure at 3 years compared with lesions with iFR >0.89 (15.4% versus 17.0%; P =0.58). CONCLUSIONS: This study suggested that FFR appears to be less affected by the presence of severe AS and is more associated with prognosis. iFR may overestimate the functional severity of coronary artery disease without prognostic significance, yet it can be useful for excluding significant stenosis in patients with severe AS.