Feng Shang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Feng Shang has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
Wenfu He
3 shared publicationsHao Xu
2 shared publicationsWenguang Liu
2 shared publications- Xiangming Zhou
Department of Civil and Environmental Engineering, Brunel University of London, London UB8 3PH, UK
2 shared publications Yafei Lou
2 shared publicationsYuzhou Sun
2 shared publications
Latest Publications
- Open Access
Seismic Performance and Strength Prediction of Precast RC Shear Walls with Openings for Cavity Structures Crossing Underground Utility Tunnels
Additional loads from new buildings spanning existing underground utility tunnels, together with seismic action, may induce uneven settlement and structural damage in tunnel systems. To mitigate this risk, a precast cavity structure is proposed to replace the soil above the tunnel, isolating load transfer and controlling settlement. In the proposed structure, precast reinforced concrete shear walls with openings serve as key vertical load-carrying and lateral-force-resisting members. To clarify the cyclic behavior, two shear walls with openings were designed to possess the same geometry and reinforcement details but were tested under reversed cyclic loading in two orthogonal in-plane orientations. The failure modes, hysteretic behavior, backbone curves, stiffness degradation, and energy-dissipation capacity were analyzed. The results show that flexural-shear failure occurred in both wall limbs under horizontal cyclic loading, whereas flexural-shear failure developed only in the right wall limb under vertical cyclic loading. The initial stiffness, peak load, peak drift ratio, and ultimate drift ratio under horizontal cyclic loading were 1.87, 2.06, 1.76, and 1.64 times those under vertical cyclic loading, respectively, indicating that the performance of the shear wall with opening is more unfavorable under vertical cyclic loading. Further, existing models were used to predict the loading-carrying capacity. The results indicate that the strut-and-tie model (STM) and GB 50010-2010 gave the best and acceptable overall predictions, respectively. The findings provide experimental evidence for component design and seismic performance evaluation of cavity replacement structures used in projects spanning underground utility tunnels.
Open AccessSeismic Performance and Strength Prediction of Precast RC Shear Walls with Openings for Cavity Structures Crossing Underground Utility Tunnels
Additional loads from new buildings spanning existing underground utility tunnels, together with seismic action, may induce uneven settlement and structural damage in tunnel systems. To mitigate this risk, a precast cavity structure is proposed to replace the soil above the tunnel, isolating load transfer and controlling settlement. In the proposed structure, precast reinforced concrete shear walls with openings serve as key vertical load-carrying and lateral-force-resisting members. To clarify the cyclic behavior, two shear walls with openings were designed to possess the same geometry and reinforcement details but were tested under reversed cyclic loading in two orthogonal in-plane orientations. The failure modes, hysteretic behavior, backbone curves, stiffness degradation, and energy-dissipation capacity were analyzed. The results show that flexural-shear failure occurred in both wall limbs under horizontal cyclic loading, whereas flexural-shear failure developed only in the right wall limb under vertical cyclic loading. The initial stiffness, peak load, peak drift ratio, and ultimate drift ratio under horizontal cyclic loading were 1.87, 2.06, 1.76, and 1.64 times those under vertical cyclic loading, respectively, indicating that the performance of the shear wall with opening is more unfavorable under vertical cyclic loading. Further, existing models were used to predict the loading-carrying capacity. The results indicate that the strut-and-tie model (STM) and GB 50010-2010 gave the best and acceptable overall predictions, respectively. The findings provide experimental evidence for component design and seismic performance evaluation of cavity replacement structures used in projects spanning underground utility tunnels.
- 10 March 2026
- Published by Elsevier in Structures
- Vol. 87
Experimental study and seismic response analysis of multi-chamber reverse viscous damping wall with amplified deformation
- 10 March 2026
- Published by Elsevier in Structures
- Vol. 87
Experimental study and seismic response analysis of multi-chamber reverse viscous damping wall with amplified deformation
- 9 December 2025
- Published by Elsevier in Journal of Building Engineering
- Vol. 117
Theoretical and experimental studies on cross-story cable-bracing viscous damper systems for structural control
- 9 December 2025
- Published by Elsevier in Journal of Building Engineering
- Vol. 117
Theoretical and experimental studies on cross-story cable-bracing viscous damper systems for structural control
- 10 August 2024
- Published by Elsevier in Journal of Building Engineering
- Vol. 96
Experimental investigation and multi-hazard evaluation of viscous outriggers with amplification devices
- 10 August 2024
- Published by Elsevier in Journal of Building Engineering
- Vol. 96
Experimental investigation and multi-hazard evaluation of viscous outriggers with amplification devices
- 17 April 2024
- Published by Wiley in The Structural Design of Tall and Special Buildings
- Vol. 33 (11)
Experimental study on viscoelastic damper with amplified mechanism and seismic mitigation evaluation
Summary: In this study, a viscoelastic damper (VED) employing an additional amplification device is proposed to enhance the stiffness as well as energy dissipation. The mechanical model of the amplified viscoelastic damper (AVED) is developed and the amplification efficiency is explored. The mechanical behaviors of AVED and the traditional VED are experimentally investigated. By adopting a leverage system, the stiffness and the dissipated energy of AVED are significantly improved and the amplification factors are confirmed. Meanwhile, the seismic responses and structural damages are addressed through a numerical study on a frame attached to the AVEDs and VEDs. The AVED reinforced building employing fewer dampers has close seismic responses compared with VED reinforced building. Furthermore, the installation of AVEDs significantly reduces the risk of structural damage.
- 17 April 2024
- Published by Wiley in The Structural Design of Tall and Special Buildings
- Vol. 33 (11)
Experimental study on viscoelastic damper with amplified mechanism and seismic mitigation evaluation
Summary: In this study, a viscoelastic damper (VED) employing an additional amplification device is proposed to enhance the stiffness as well as energy dissipation. The mechanical model of the amplified viscoelastic damper (AVED) is developed and the amplification efficiency is explored. The mechanical behaviors of AVED and the traditional VED are experimentally investigated. By adopting a leverage system, the stiffness and the dissipated energy of AVED are significantly improved and the amplification factors are confirmed. Meanwhile, the seismic responses and structural damages are addressed through a numerical study on a frame attached to the AVEDs and VEDs. The AVED reinforced building employing fewer dampers has close seismic responses compared with VED reinforced building. Furthermore, the installation of AVEDs significantly reduces the risk of structural damage.
- 1 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 47, 498-502
Design of four-arm sinuous antenna used in wireless positioning detection system
In a wireless positioning detection system, an antenna is needed to receive satellite signals and accurately locate the target’s location. A flat-printed four-arm sinuous antenna is designed, which has the advantages of wide frequency band, compact structure and small size. It uses double-sided gradual microstrip balun to feed, and realizes double circular polarization. The antenna is improved by installing a reflective cavity. After the simulation and actual measurement results show that the antenna gain has reached 8dB in the l-2.6Ghz frequency band, and has a good voltage standing wave ratio (VSWR), both are less than 2. At the same time, the satellite signal reception quality test was carried out in conjunction with the entire system, and the effect of the signal-to-noise ratio and the number of receiving satellites performed well, meeting the system requirements.
- 1 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 47, 498-502
Design of four-arm sinuous antenna used in wireless positioning detection system
In a wireless positioning detection system, an antenna is needed to receive satellite signals and accurately locate the target’s location. A flat-printed four-arm sinuous antenna is designed, which has the advantages of wide frequency band, compact structure and small size. It uses double-sided gradual microstrip balun to feed, and realizes double circular polarization. The antenna is improved by installing a reflective cavity. After the simulation and actual measurement results show that the antenna gain has reached 8dB in the l-2.6Ghz frequency band, and has a good voltage standing wave ratio (VSWR), both are less than 2. At the same time, the satellite signal reception quality test was carried out in conjunction with the entire system, and the effect of the signal-to-noise ratio and the number of receiving satellites performed well, meeting the system requirements.