Matea Vinković Vlah
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Matea Vinković Vlah has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Allison Waters
Irish Blood Transfusion Service National Blood Centre Dublin Ireland
2 shared publications - Christian Erikstrup
Department of Clinical Immunology, Aarhus University Hospital, Aarhus, Denmark
2 shared publications - Katja van Den Hurk
Donor Health, Department of Research Sanquin Blood Supply Foundation Amsterdam The Netherlands
2 shared publications Louise Ørnskov Drechsler
Department of Clinical Immunology Aarhus University Hospital Aarhus Denmark
2 shared publications- Mikko Arvas
Finnish Red Cross Blood Service Vantaa Finland
2 shared publications - Simon J. Stanworth
NHS Blood and Transplant Bristol UK
2 shared publications
Latest Publications
- Open Access
- 18 August 2026
- Published by Wiley in Vox Sanguinis
- Vol. 121 (11) , 1719-1725
Opportunities for vein‐to‐vein datasets from a blood establishment perspective: Towards a ‘Pan‐European Transfusion Research InfrAstructure ’
Background and Objectives: The ‘Pan‐European Transfusion Research InfrAstructure’ (PETRA) project was established to advance the use of donor, blood product and patient datasets in Europe, aiming to benefit both patient and donor health. Here, the initial PETRA objective was to describe the landscape of existing donor and blood establishment (BE) databases. Materials and Methods: An online survey was circulated to the European Blood Alliance's BE‐members. The survey collected information on the feasibility of accessing donor data, and challenges and possibilities for linking these datasets with information on the associated blood products and transfusion recipients, and donors' own health records. Results: Seventeen BEs across 16 countries completed the survey. The majority could, in principle, link their donor data to product data (13 BEs, 76%) and recipient data (10 BEs, 59%) for research purposes. However, capabilities were limited and in only 5 of 17 BEs was the donor to recipients' linkage an automated process. BEs reported significant challenges to achieve full vein‐to‐vein linkage, including legal constraints and lack of consent (11 BEs) and resources (10–14 BEs). Information technology and data issues as well as lack of knowledge and training were cited as obstacles by a minority of BEs. Conclusion: Whilst the survey results suggest considerable interest in developing linkages between blood donors, their products and recipients, many challenges remain due to a variety of obstacles. First steps in working towards a PETRA may be assistance to navigate legal frameworks as well as investing in resources and quality and harmonization of data collections.
- 18 August 2026
- Published by Wiley in Vox Sanguinis
- Vol. 121 (11) , 1719-1725
Open AccessOpportunities for vein‐to‐vein datasets from a blood establishment perspective: Towards a ‘Pan‐European Transfusion Research InfrAstructure ’
Background and Objectives: The ‘Pan‐European Transfusion Research InfrAstructure’ (PETRA) project was established to advance the use of donor, blood product and patient datasets in Europe, aiming to benefit both patient and donor health. Here, the initial PETRA objective was to describe the landscape of existing donor and blood establishment (BE) databases. Materials and Methods: An online survey was circulated to the European Blood Alliance's BE‐members. The survey collected information on the feasibility of accessing donor data, and challenges and possibilities for linking these datasets with information on the associated blood products and transfusion recipients, and donors' own health records. Results: Seventeen BEs across 16 countries completed the survey. The majority could, in principle, link their donor data to product data (13 BEs, 76%) and recipient data (10 BEs, 59%) for research purposes. However, capabilities were limited and in only 5 of 17 BEs was the donor to recipients' linkage an automated process. BEs reported significant challenges to achieve full vein‐to‐vein linkage, including legal constraints and lack of consent (11 BEs) and resources (10–14 BEs). Information technology and data issues as well as lack of knowledge and training were cited as obstacles by a minority of BEs. Conclusion: Whilst the survey results suggest considerable interest in developing linkages between blood donors, their products and recipients, many challenges remain due to a variety of obstacles. First steps in working towards a PETRA may be assistance to navigate legal frameworks as well as investing in resources and quality and harmonization of data collections.
- Open Access
Opportunities for Vein-to-Vein Datasets from a Blood Establishment Perspective: towards a “Pan-European Transfusion Research InfrAstructure” (PETRA)
Iii. Background and Objectives: The “Pan-European Transfusion Research InfrAstructure” (PETRA) project was established to advance the use of donor, blood product, and patient datasets in Europe, aiming to benefit both patient and donor health. Here, the initial PETRA objective was to describe the landscape of existing donor and blood establishment (BE) databases. Materials and Methods: An online survey was circulated to the European Blood Alliance’s BE members. The survey collected information on the feasibility of accessing donor data, and challenges and possibilities for linking these datasets with information on the associated blood products and transfusion recipients, and donors’ own health records. Results: Seventeen BEs across 16 countries completed the survey. The majority could, in principle, link their donor data to product data (13 BEs (76%)) and recipient data (10 BEs (59%)), for research purposes. However, capabilities were limited and in only 29% of the BEs was the donor to recipients’ linkage an automated process. BEs reported significant challenges to achieve full vein-to-vein linkage, including legal constraints and lack of consent (11 BEs) and resources (10-14 BEs). IT and data issues as well as lack of knowledge and training were cited as obstacles by a minority of BEs. Conclusion: Whilst the survey results suggest considerable interest in developing linkages between blood donors, their products, and recipients, many challenges remain due to a variety of obstacles. First steps in working towards a PETRA may be assistance to navigate legal frameworks as well as investing in resources and quality and harmonisation of data collections. iv. Highlights: 17 blood establishments (BEs) in 16 countries responded to a survey on obstacles and opportunities for achieving vein-to-vein datasets. In 59% of the BEs donor-to-recipient links can be established for research improving transfusion outcomes, but only in 29% this is an automated process. In order to work towards a “Pan-European Transfusion Research InfrAstructure” (PETRA), legal frameworks, adequate donor consent and (financial and human) resources are the most common obstacles that require addressing.
Open AccessOpportunities for Vein-to-Vein Datasets from a Blood Establishment Perspective: towards a “Pan-European Transfusion Research InfrAstructure” (PETRA)
Iii. Background and Objectives: The “Pan-European Transfusion Research InfrAstructure” (PETRA) project was established to advance the use of donor, blood product, and patient datasets in Europe, aiming to benefit both patient and donor health. Here, the initial PETRA objective was to describe the landscape of existing donor and blood establishment (BE) databases. Materials and Methods: An online survey was circulated to the European Blood Alliance’s BE members. The survey collected information on the feasibility of accessing donor data, and challenges and possibilities for linking these datasets with information on the associated blood products and transfusion recipients, and donors’ own health records. Results: Seventeen BEs across 16 countries completed the survey. The majority could, in principle, link their donor data to product data (13 BEs (76%)) and recipient data (10 BEs (59%)), for research purposes. However, capabilities were limited and in only 29% of the BEs was the donor to recipients’ linkage an automated process. BEs reported significant challenges to achieve full vein-to-vein linkage, including legal constraints and lack of consent (11 BEs) and resources (10-14 BEs). IT and data issues as well as lack of knowledge and training were cited as obstacles by a minority of BEs. Conclusion: Whilst the survey results suggest considerable interest in developing linkages between blood donors, their products, and recipients, many challenges remain due to a variety of obstacles. First steps in working towards a PETRA may be assistance to navigate legal frameworks as well as investing in resources and quality and harmonisation of data collections. iv. Highlights: 17 blood establishments (BEs) in 16 countries responded to a survey on obstacles and opportunities for achieving vein-to-vein datasets. In 59% of the BEs donor-to-recipient links can be established for research improving transfusion outcomes, but only in 29% this is an automated process. In order to work towards a “Pan-European Transfusion Research InfrAstructure” (PETRA), legal frameworks, adequate donor consent and (financial and human) resources are the most common obstacles that require addressing.
- Open Access
- 4 January 2026
- Published by Wiley in Vox Sanguinis
- Vol. 121 (3) , 254-261
Monitoring bacterial contamination of blood components at the Croatian Institute of Transfusion Medicine—Evolution of strategies and results in a 14‐year period (2011–2024)
Background and Objectives: This study presents the results and experiences of bacterial testing of blood components (BCs) at the Croatian Institute of Transfusion Medicine during the period 2011–2024. Materials and Methods: During the 14‐year period, 74,283 BCs were tested. Among these, 20,231 components (8345 red blood cell concentrates, 5729 platelet concentrates [PCs] and 6157 plasma units) were tested as part of statistical quality control (QC). In addition, 100% bacterial screening was implemented for aphaeresis platelets in November 2019 and for pooled platelets in October 2022 with 17,187 aphaeresis platelets and 36,865 pooled platelets tested by the end of 2024. All pooled platelets were tested using the large‐volume delayed sampling (LVDS) method, whereas 9596 aphaeresis platelets were tested using the two‐step method (from November 2019 to November 2022) and 7591 using LVDS (from November 2022 to December 2024). BCs were sampled and inoculated into both aerobic and anaerobic culture bottles and incubated at 36 ± 1°C for 7 days. Results: As part of the statistical QC, 20,231 BCs (5729 PCs) were tested, resulting in a confirmed contamination rate of 0.09% (0.14% for PCs). Since the implementation of universal screening, 54,052 PCs have been examined, with a confirmed positivity rate of 0.18%. The most frequently detected organism was Cutibacterium acnes . Conclusion: The confirmed positive rate of bacterial testing in our study and the isolates from positive cultures are comparable to similar studies. Active bacterial screening of BCs, among other measures, remains a critical step for preventing transfusion‐associated bacterial infections.
- 4 January 2026
- Published by Wiley in Vox Sanguinis
- Vol. 121 (3) , 254-261
Open AccessMonitoring bacterial contamination of blood components at the Croatian Institute of Transfusion Medicine—Evolution of strategies and results in a 14‐year period (2011–2024)
Background and Objectives: This study presents the results and experiences of bacterial testing of blood components (BCs) at the Croatian Institute of Transfusion Medicine during the period 2011–2024. Materials and Methods: During the 14‐year period, 74,283 BCs were tested. Among these, 20,231 components (8345 red blood cell concentrates, 5729 platelet concentrates [PCs] and 6157 plasma units) were tested as part of statistical quality control (QC). In addition, 100% bacterial screening was implemented for aphaeresis platelets in November 2019 and for pooled platelets in October 2022 with 17,187 aphaeresis platelets and 36,865 pooled platelets tested by the end of 2024. All pooled platelets were tested using the large‐volume delayed sampling (LVDS) method, whereas 9596 aphaeresis platelets were tested using the two‐step method (from November 2019 to November 2022) and 7591 using LVDS (from November 2022 to December 2024). BCs were sampled and inoculated into both aerobic and anaerobic culture bottles and incubated at 36 ± 1°C for 7 days. Results: As part of the statistical QC, 20,231 BCs (5729 PCs) were tested, resulting in a confirmed contamination rate of 0.09% (0.14% for PCs). Since the implementation of universal screening, 54,052 PCs have been examined, with a confirmed positivity rate of 0.18%. The most frequently detected organism was Cutibacterium acnes . Conclusion: The confirmed positive rate of bacterial testing in our study and the isolates from positive cultures are comparable to similar studies. Active bacterial screening of BCs, among other measures, remains a critical step for preventing transfusion‐associated bacterial infections.
- 17 April 2024
- Published by Wiley in Vox Sanguinis
- Vol. 119 (7) , 686-692
Aggregates in apheresis‐derived platelet concentrates: A 5‐year single‐centre experience
Background and Objectives: The phenomenon of aggregates in apheresis‐derived platelet concentrates (APCs) has not yet been fully elucidated. Initially, visible aggregates (IVA) usually dissolve within 24 h after collection, but some persist till the end of the shelf life (persistent aggregates, PA). A study conducted at the Croatian Institute of Transfusion Medicine aimed to identify factors that influence the aggregate occurrence in APCs.Materials and Methods: We conducted a cross‐sectional study for the 2018–2022 period and collected data on APCs with IVA. We analysed APCs discarded due to PA separately for two apheresis technologies and compared them to the control group.Results: Significantly more donations were discarded in the IVA group compared with the control group and total number of discarded APCs. A total of 205 APCs were discarded due to PA (14.7% of IVA APCs and 1.27% of all APCs collected). Amicus APCs with PA had a significantly lower platelet count and mean platelet volume. They were obtained by procedures with less anticoagulant used. In contrast to Amicus APCs, Haemonetics APCs with PA had a significantly higher platelet count. None of the donor‐related factors examined was predictive of PA.Conclusion: APCs with IVA are more often discarded, not only due to aggregates, but also for impairment of other quality control parameters. Type of apheresis technology, being one of the most common risk factors for IVA, was not confirmed as the main risk factor for PA. There seem to be some donor‐related causal factors.
- 17 April 2024
- Published by Wiley in Vox Sanguinis
- Vol. 119 (7) , 686-692
Aggregates in apheresis‐derived platelet concentrates: A 5‐year single‐centre experience
Background and Objectives: The phenomenon of aggregates in apheresis‐derived platelet concentrates (APCs) has not yet been fully elucidated. Initially, visible aggregates (IVA) usually dissolve within 24 h after collection, but some persist till the end of the shelf life (persistent aggregates, PA). A study conducted at the Croatian Institute of Transfusion Medicine aimed to identify factors that influence the aggregate occurrence in APCs.Materials and Methods: We conducted a cross‐sectional study for the 2018–2022 period and collected data on APCs with IVA. We analysed APCs discarded due to PA separately for two apheresis technologies and compared them to the control group.Results: Significantly more donations were discarded in the IVA group compared with the control group and total number of discarded APCs. A total of 205 APCs were discarded due to PA (14.7% of IVA APCs and 1.27% of all APCs collected). Amicus APCs with PA had a significantly lower platelet count and mean platelet volume. They were obtained by procedures with less anticoagulant used. In contrast to Amicus APCs, Haemonetics APCs with PA had a significantly higher platelet count. None of the donor‐related factors examined was predictive of PA.Conclusion: APCs with IVA are more often discarded, not only due to aggregates, but also for impairment of other quality control parameters. Type of apheresis technology, being one of the most common risk factors for IVA, was not confirmed as the main risk factor for PA. There seem to be some donor‐related causal factors.