Swee-Lu Lim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Swee-Lu Lim has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Daniel C. Elkington
Centre for Organic Electronics, The University of Newcastle , Callaghan, NSW 2308
2 shared publications Kristofer L. Thompson
Centre for Organic Electronics, The University of Newcastle , Callaghan, NSW 2308
2 shared publications- Nathan A. Cooling
Centre for Organic Electronics, The University of Newcastle , Callaghan, NSW 2308
2 shared publications - Nguyen Trieu Trinh
Centre for Organic Electronics, The University of Newcastle , Callaghan, NSW 2308
2 shared publications - Paul Christopher Dastoor
University of Newcastle , Callaghan
2 shared publications Tim Lewis
Centre for Organic Electronics, The University of Newcastle , Callaghan, NSW 2308
2 shared publications
Latest Publications
- Open Access
- 15 December 2025
- Published by AIP Publishing in Applied Physics Letters
- Vol. 127 (24)
Printed organic electronic sensors for glucose detection in human saliva
Diabetes mellitus is a chronic condition which is approaching epidemic levels globally. Sufferers of diabetes require regular monitoring of their blood glucose levels for successful treatment and the current widely used methods are invasive and painful. There is therefore an urgent need for simple, noninvasive methods of blood glucose concentration monitoring. Saliva is a medium whose glucose concentration correlates well with that of glucose in blood, while readily allowing noninvasive and pain-free sampling. Here, we demonstrate organic enzymatic glucose sensors fabricated at pilot-scale and at low cost, which show high sensitivity to glucose in human saliva for biologically relevant concentrations (up to 0.2 mM) and a limit of detection of 0.029 mM. Additionally, we show that the devices are highly selective for glucose in the presence of key interferents such as ascorbic acid and uric acid.
- 15 December 2025
- Published by AIP Publishing in Applied Physics Letters
- Vol. 127 (24)
Open AccessPrinted organic electronic sensors for glucose detection in human saliva
Diabetes mellitus is a chronic condition which is approaching epidemic levels globally. Sufferers of diabetes require regular monitoring of their blood glucose levels for successful treatment and the current widely used methods are invasive and painful. There is therefore an urgent need for simple, noninvasive methods of blood glucose concentration monitoring. Saliva is a medium whose glucose concentration correlates well with that of glucose in blood, while readily allowing noninvasive and pain-free sampling. Here, we demonstrate organic enzymatic glucose sensors fabricated at pilot-scale and at low cost, which show high sensitivity to glucose in human saliva for biologically relevant concentrations (up to 0.2 mM) and a limit of detection of 0.029 mM. Additionally, we show that the devices are highly selective for glucose in the presence of key interferents such as ascorbic acid and uric acid.
- Open Access
- 22 April 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 124 (17)
Upscaling laboratory organic electronic sensor devices to roll-to-roll printing: The effect of printable electrodes on device operation
The prospect of large-scale production of low-cost electronic devices is a driving factor behind the recent interest in printed organic electronics. However, the upscaling of laboratory organic electronic devices is extremely challenging since it requires the adaptation of materials and fabrication processes optimized for the small scale to industrial manufacturing techniques, such as roll-to-roll printing. Here, we demonstrate the fabrication of all-printed organic biosensors at the pilot production scale for use in the detection of glucose. By translating device architecture and operation, as well as electrode design and ink formulations of previously reported laboratory-scale glucose sensors to industrial printing and coating processes, we demonstrate sub-millimolar sensitivity to glucose in fully printed devices in a process which is now scalable to commercial production quantities. This Letter highlights the significant challenges associated with developing upscaled printed organic electronic biosensors and the approaches needed to address them.
- 22 April 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 124 (17)
Open AccessUpscaling laboratory organic electronic sensor devices to roll-to-roll printing: The effect of printable electrodes on device operation
The prospect of large-scale production of low-cost electronic devices is a driving factor behind the recent interest in printed organic electronics. However, the upscaling of laboratory organic electronic devices is extremely challenging since it requires the adaptation of materials and fabrication processes optimized for the small scale to industrial manufacturing techniques, such as roll-to-roll printing. Here, we demonstrate the fabrication of all-printed organic biosensors at the pilot production scale for use in the detection of glucose. By translating device architecture and operation, as well as electrode design and ink formulations of previously reported laboratory-scale glucose sensors to industrial printing and coating processes, we demonstrate sub-millimolar sensitivity to glucose in fully printed devices in a process which is now scalable to commercial production quantities. This Letter highlights the significant challenges associated with developing upscaled printed organic electronic biosensors and the approaches needed to address them.