Roberto D’aniello
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Roberto D’aniello has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Gaetano Motta
ENT Unit, Department of Mental, Physical Health and Preventive Medicine, University of Campania “Luigi Vanvitelli”, 80131 Naples, Italy
2 shared publications - Giovanni Motta
ENT Unit, Department of Mental, Physical Health and Preventive Medicine, University of Campania “Luigi Vanvitelli”, 80131 Naples, Italy
2 shared publications - Giuseppe Quaremba
Department of Advanced Biomedical Sciences, Federico II University of Naples, 80131 Naples, Italy
2 shared publications - Grazia Salerno
Unit of Otorhinolaryngology, Department of Neuroscience, Reproductive Sciences and Dentistry, University Federico II of Naples, 80131 Naples, Italy
2 shared publications - Massimo Mesolella
Unit of Otorhinolaryngology, Department of Neuroscience, Reproductive Sciences and Dentistry, University of Naples Federico II, 80131 Naples, Italy
2 shared publications - Salvatore Allosso
Unit of Otorhinolaryngology, Department of Neuroscience, Reproductive Sciences and Dentistry, University of Naples Federico II, 80131 Naples, Italy
2 shared publications
Latest Publications
- Open Access
- 27 May 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (11) , 3137
Quality of Life and Respiratory Performance in the Laryngectomized Patient: Role of the HME Filters during Physical Activity
Background: Permanent tracheostomy because of total laryngectomy surgery entails significant consequences for patients regarding respiratory physiopathology, such as the loss of the filtering, humidifying, and heating of air by the nose. The use of special stomal filters can provide adequate protection of the tracheal–bronchopulmonary system with a reduction in respiratory pathologies. In fact, in most cases, laryngectomy patients are first cigarette smokers who for this reason also already have respiratory diseases such as chronic obstructive pulmonary disease (COPD). Despite the availability of tracheal filters, as reported in the literature, patients often tend to limit their use due to reported breathing difficulties, especially in conditions of intense breathing. Methods: The objective of this clinical study was to evaluate the most suitable stomal filter for laryngectomy patients during physical activity. The filters studied were an INHEALTH device (Blom-Singer SpeakFree HME); two ATOS devices (Provox® Life™ Energy HME and Provox® Life™ Home HME); and an FAHL device (Laryvox HME Sport). Results: For this purpose, the performances of 31 laryngectomy patients, subjected to medium–high physical effort, were analyzed through a standardized pneumological test, the Six Minute Walking Test (6MWT), which involves a sustained walk lasting six minutes, with an evaluation of heart rate, oxygen saturation, and meters traveled every 60 s; furthermore, we examined two subjective indices, namely, the basal and final dyspnea index and the initial and final muscular fatigue index. Conclusions: The multidisciplinary approach of the laryngectomee patient must also take pulmonary rehabilitation into consideration. It is the task of the medical team and speech therapy support to help the patient in the correct choice of HME filters taking into account daily needs.
- 27 May 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (11) , 3137
Open AccessQuality of Life and Respiratory Performance in the Laryngectomized Patient: Role of the HME Filters during Physical Activity
Background: Permanent tracheostomy because of total laryngectomy surgery entails significant consequences for patients regarding respiratory physiopathology, such as the loss of the filtering, humidifying, and heating of air by the nose. The use of special stomal filters can provide adequate protection of the tracheal–bronchopulmonary system with a reduction in respiratory pathologies. In fact, in most cases, laryngectomy patients are first cigarette smokers who for this reason also already have respiratory diseases such as chronic obstructive pulmonary disease (COPD). Despite the availability of tracheal filters, as reported in the literature, patients often tend to limit their use due to reported breathing difficulties, especially in conditions of intense breathing. Methods: The objective of this clinical study was to evaluate the most suitable stomal filter for laryngectomy patients during physical activity. The filters studied were an INHEALTH device (Blom-Singer SpeakFree HME); two ATOS devices (Provox® Life™ Energy HME and Provox® Life™ Home HME); and an FAHL device (Laryvox HME Sport). Results: For this purpose, the performances of 31 laryngectomy patients, subjected to medium–high physical effort, were analyzed through a standardized pneumological test, the Six Minute Walking Test (6MWT), which involves a sustained walk lasting six minutes, with an evaluation of heart rate, oxygen saturation, and meters traveled every 60 s; furthermore, we examined two subjective indices, namely, the basal and final dyspnea index and the initial and final muscular fatigue index. Conclusions: The multidisciplinary approach of the laryngectomee patient must also take pulmonary rehabilitation into consideration. It is the task of the medical team and speech therapy support to help the patient in the correct choice of HME filters taking into account daily needs.
- Open Access
- 25 April 2024
- Published by MDPI AG in Preprints.org
Quality of Life and Respiratory Performance in the Laryngectomized Patient. Role of the Hme Filters during Physical Activity
Background: Permanent tracheostomy because of total laryngectomy surgery entails great conse-quences for the patient regarding respiratory physiopathology such as the filtering, humidifying, and heating function of the air by the nose is lost. The use of special stomal filters can determine adequate protection of the trachea-broncho-pulmonary system with a reduction in respiratory pathologies. In fact, in most cases laryngectomee patients are first cigarette smokers who for this reason already have also respiratory diseases such as chronic obstructive pulmonary disease (COPD). Despite the availability of tracheal filters, multiple times, as reported in the literature, the patient tends to limit their use due to reported breathing difficulties, especially in conditions of intense breathing. Methods: The objective of this clinical study was to evaluate the most suitable stomal filter for the laryngectomee patient during physical activity. The filters studied were an INHEALTH device (Blom-Singer SpeakFree HME); two ATOS devices (Provox® Life™ Energy HME and Provox® Life™ Home HME); and an FAHL device (Laryvox HME Sport). Results: For this purpose, the performances of 31 laryngectomee patients, subjected to medi-um-high physical effort, were analyzed through a standardized pneumological test, the Six Minute Walking Test (6MWT) which involves a sustained walk lasting six minutes, with evaluation , every 60 seconds, heart rate, oxygen saturation and meters travelled; furthermore, it examines two sub-jective indices, namely, the basal and final dyspnea index and the initial and final muscular fatigue index.
- 25 April 2024
- Published by MDPI AG in Preprints.org
Open AccessQuality of Life and Respiratory Performance in the Laryngectomized Patient. Role of the Hme Filters during Physical Activity
Background: Permanent tracheostomy because of total laryngectomy surgery entails great conse-quences for the patient regarding respiratory physiopathology such as the filtering, humidifying, and heating function of the air by the nose is lost. The use of special stomal filters can determine adequate protection of the trachea-broncho-pulmonary system with a reduction in respiratory pathologies. In fact, in most cases laryngectomee patients are first cigarette smokers who for this reason already have also respiratory diseases such as chronic obstructive pulmonary disease (COPD). Despite the availability of tracheal filters, multiple times, as reported in the literature, the patient tends to limit their use due to reported breathing difficulties, especially in conditions of intense breathing. Methods: The objective of this clinical study was to evaluate the most suitable stomal filter for the laryngectomee patient during physical activity. The filters studied were an INHEALTH device (Blom-Singer SpeakFree HME); two ATOS devices (Provox® Life™ Energy HME and Provox® Life™ Home HME); and an FAHL device (Laryvox HME Sport). Results: For this purpose, the performances of 31 laryngectomee patients, subjected to medi-um-high physical effort, were analyzed through a standardized pneumological test, the Six Minute Walking Test (6MWT) which involves a sustained walk lasting six minutes, with evaluation , every 60 seconds, heart rate, oxygen saturation and meters travelled; furthermore, it examines two sub-jective indices, namely, the basal and final dyspnea index and the initial and final muscular fatigue index.