Bert Schiebler
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Bert Schiebler has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Julian Jensen
Institut für Solarenergieforschung image/svg+xml
3 shared publications Federico Giovannetti
Institut für Solarenergieforschung image/svg+xml
2 shared publications- Federico Giovannetti
Institute for Solar Energy Research (ISFH)
2 shared publications - Alexis Duret
Haute ecole d'ingenierie et de gestion du canton de Vaud
1 shared publication Christian Kloibhofer
GASOKOL GmbH
1 shared publication- Daniel Tschopp
AEE Institute for Sustainable Technologies
1 shared publication
Latest Publications
- Open Access
- 15 October 2026
- Published by Elsevier in Solar Energy
- Vol. 319
Overheating prevention in large-scale solar thermal systems based on heat pipe collectors
- 15 October 2026
- Published by Elsevier in Solar Energy
- Vol. 319
Open AccessOverheating prevention in large-scale solar thermal systems based on heat pipe collectors
- Open Access
- 26 February 2026
- Published by TIB Open Publishing in Solarthermie-Symposium Proceedings
- Vol. 2
Stagnation in Large-Scale Solar Thermal Systems? Experiences From Recent Installations as Motivation for Heat Pipe Collectors in a Novel System Design
Large-scale solar thermal systems supplying heating networks can make a significant contribution to the decarbonization of the heating sector and are becoming increasingly relevant in practice. The first part of the paper analyses 30 realized systems in Germany focusing on collector area, heat storage capacity and stagnation events. More than 60 % of these systems have heat storage capacities smaller than 100 l/m² collector area. Nevertheless, a third of the systems reaches an annual solar fraction of over 20 %. Our investigations for such dimensioned systems report a number of 20 to 43 stagnation days per year, depending on the storage capacity. The relevance of stagnation load motivates our research activities to avoid its negative consequences in large-scale systems. The second part of the paper describes the development of evacuated tube collectors with inherent overheating prevention as well as the outdoor tests we carried out with various prototypes at our sun tracker. The collector concepts are based on heat pipes with temperature limitation to 125-135 °C in the solar circuit and are therefore able to avoid evaporation of the heat transfer medium. Due to lower stagnation loads, we investigate the possibility of using polymeric pipes instead of steel pipes for the solar circuit and discuss an integrated system concept. The innovative collector and system design are implemented in a demonstration plant that we will monitor during the construction phase and in operation.
- 26 February 2026
- Published by TIB Open Publishing in Solarthermie-Symposium Proceedings
- Vol. 2
Open AccessStagnation in Large-Scale Solar Thermal Systems? Experiences From Recent Installations as Motivation for Heat Pipe Collectors in a Novel System Design
Large-scale solar thermal systems supplying heating networks can make a significant contribution to the decarbonization of the heating sector and are becoming increasingly relevant in practice. The first part of the paper analyses 30 realized systems in Germany focusing on collector area, heat storage capacity and stagnation events. More than 60 % of these systems have heat storage capacities smaller than 100 l/m² collector area. Nevertheless, a third of the systems reaches an annual solar fraction of over 20 %. Our investigations for such dimensioned systems report a number of 20 to 43 stagnation days per year, depending on the storage capacity. The relevance of stagnation load motivates our research activities to avoid its negative consequences in large-scale systems. The second part of the paper describes the development of evacuated tube collectors with inherent overheating prevention as well as the outdoor tests we carried out with various prototypes at our sun tracker. The collector concepts are based on heat pipes with temperature limitation to 125-135 °C in the solar circuit and are therefore able to avoid evaporation of the heat transfer medium. Due to lower stagnation loads, we investigate the possibility of using polymeric pipes instead of steel pipes for the solar circuit and discuss an integrated system concept. The innovative collector and system design are implemented in a demonstration plant that we will monitor during the construction phase and in operation.
- Open Access
- 24 January 2026
- Published by Springer Nature
- p. 31-39
Large-Scale Solar Thermal Systems in District Heating Networks: A Review of German Projects Regarding Dimensioning, Temperatures and Stagnation Times
The district heating sector in Germany needs to be supplied increasingly from renewable sources. Large-scale solar thermal systems can make a significant contribution to this process. The paper analyzes 38 concepts of feasibility studies as well as 30 realized systems by investigating relevant designing parameters. Network supply temperatures of around 75 °C and 80 °C are very common for the feed-in of solar thermal energy. The achievable solar fraction is strongly dependent on the storage capacity. A doubling of solar fraction typically requires a tenfold increase in storage volume. The installed storage capacity is often smaller than 100 l/m 2 . Large seasonal storages, as usual in Denmark, are very seldom in Germany so far. Thus, stagnation events become more relevant in large-scale systems, as we report from the realized projects. Systems with solar fractions of around 20%, which are typical for district heating networks especially in countryside regions, achieve up to 50 stagnation days per year, a representative stagnation day is analyzed for one monitored system. Finally, the paper addresses possible causes of stagnation and discusses a prevention strategy by using heat pipe collectors with inherent temperature limitation.
- 24 January 2026
- Published by Springer Nature
- p. 31-39
Open AccessLarge-Scale Solar Thermal Systems in District Heating Networks: A Review of German Projects Regarding Dimensioning, Temperatures and Stagnation Times
The district heating sector in Germany needs to be supplied increasingly from renewable sources. Large-scale solar thermal systems can make a significant contribution to this process. The paper analyzes 38 concepts of feasibility studies as well as 30 realized systems by investigating relevant designing parameters. Network supply temperatures of around 75 °C and 80 °C are very common for the feed-in of solar thermal energy. The achievable solar fraction is strongly dependent on the storage capacity. A doubling of solar fraction typically requires a tenfold increase in storage volume. The installed storage capacity is often smaller than 100 l/m 2 . Large seasonal storages, as usual in Denmark, are very seldom in Germany so far. Thus, stagnation events become more relevant in large-scale systems, as we report from the realized projects. Systems with solar fractions of around 20%, which are typical for district heating networks especially in countryside regions, achieve up to 50 stagnation days per year, a representative stagnation day is analyzed for one monitored system. Finally, the paper addresses possible causes of stagnation and discusses a prevention strategy by using heat pipe collectors with inherent temperature limitation.
- Open Access
- 24 April 2024
- Published by TIB Open Publishing in International Sustainable Energy Conference - Proceedings
- Vol. 1
SunPeek Open-Source Software for ISO 24194 Performance Assessment and Monitoring of Large-Scale Solar Thermal Plants
ISO 24194:2022, the first standard specifically designed to assess the operational performance of solar thermal collector arrays, is likely to have substantial impact on the entire solar thermal industry. This standard introduces the Power Check, a method that can be used for monitoring ongoing plant operation and for checking performance guarantees. However, its practical use is presently limited, as initial applications indicate a need for clarification, and it exists as a mere paper description, rendering it less accessible for plant designers and operators. Furthermore, any implementation necessitates practical decisions regarding data handling and algorithm implementation. Closed-source implementations, lacking a traceable and transparent framework, could lead to inconsistent results. To address these issues, this paper introduces SunPeek, an open-source software that provides a reference implementation of the ISO 24194 Power Check. SunPeek is freely accessible for both scientific and commercial purposes. This paper also discusses existing limitations of ISO 24194 and showcases five examples of SunPeek applied to real-life solar thermal plants. This underscores potential practical challenges, such as handling stagnation events, and highlights methodological progress, such as improved data filtering for performance analyses. The findings and applications indicate SunPeek’s usability and the high potential for ISO 24194-based performance monitoring of solar thermal plants.
- 24 April 2024
- Published by TIB Open Publishing in International Sustainable Energy Conference - Proceedings
- Vol. 1
Open AccessSunPeek Open-Source Software for ISO 24194 Performance Assessment and Monitoring of Large-Scale Solar Thermal Plants
ISO 24194:2022, the first standard specifically designed to assess the operational performance of solar thermal collector arrays, is likely to have substantial impact on the entire solar thermal industry. This standard introduces the Power Check, a method that can be used for monitoring ongoing plant operation and for checking performance guarantees. However, its practical use is presently limited, as initial applications indicate a need for clarification, and it exists as a mere paper description, rendering it less accessible for plant designers and operators. Furthermore, any implementation necessitates practical decisions regarding data handling and algorithm implementation. Closed-source implementations, lacking a traceable and transparent framework, could lead to inconsistent results. To address these issues, this paper introduces SunPeek, an open-source software that provides a reference implementation of the ISO 24194 Power Check. SunPeek is freely accessible for both scientific and commercial purposes. This paper also discusses existing limitations of ISO 24194 and showcases five examples of SunPeek applied to real-life solar thermal plants. This underscores potential practical challenges, such as handling stagnation events, and highlights methodological progress, such as improved data filtering for performance analyses. The findings and applications indicate SunPeek’s usability and the high potential for ISO 24194-based performance monitoring of solar thermal plants.
- Open Access
Performance Evaluation of an Evacuated Tube Collector with a Low-Cost Diffuse Reflector
In order to increase the overall solar energy gain of evacuated tube collectors, rear-side reflectors are used. In this way, the otherwise unused incident radiation between the tubes can be reflected back to the absorber, and the performance of the collector can be improved. In this paper, the use of a low-cost, diffusely reflecting, trapezoidal roof covering made from a galvanized metal sheet is investigated and compared to a high-quality, specularly reflecting plane reflector made of aluminum. For this purpose, ray-tracing analysis and TRNSYS simulations were carried out. In the ray-tracing analysis, the experimentally determined zero-loss collector efficiency η0 as well as the incident angle modifiers for each reflector can be reproduced with an error lower than 7.5%. Thermal system simulations show that the performance of both reflectors is comparable. The use of the low-cost reflector leads to an increase in annual collector output of around 30% compared to an increase with the specular reflector of around 33%. Considering a typical domestic hot water system, both reflectors enable an increase in the solar annual yield of approx. 11%.
Open AccessPerformance Evaluation of an Evacuated Tube Collector with a Low-Cost Diffuse Reflector
In order to increase the overall solar energy gain of evacuated tube collectors, rear-side reflectors are used. In this way, the otherwise unused incident radiation between the tubes can be reflected back to the absorber, and the performance of the collector can be improved. In this paper, the use of a low-cost, diffusely reflecting, trapezoidal roof covering made from a galvanized metal sheet is investigated and compared to a high-quality, specularly reflecting plane reflector made of aluminum. For this purpose, ray-tracing analysis and TRNSYS simulations were carried out. In the ray-tracing analysis, the experimentally determined zero-loss collector efficiency η0 as well as the incident angle modifiers for each reflector can be reproduced with an error lower than 7.5%. Thermal system simulations show that the performance of both reflectors is comparable. The use of the low-cost reflector leads to an increase in annual collector output of around 30% compared to an increase with the specular reflector of around 33%. Considering a typical domestic hot water system, both reflectors enable an increase in the solar annual yield of approx. 11%.