Jian Gao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jian Gao has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Chuanfeng Fan
Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, MOE, Shandong Provincial Key Laboratory of Biochemical Engineering, Qingdao Nucleic Acid Rapid Detection Engineering Research Center, College of Marine Science and Biological Engineering, Qingdao University of Science and Technology, Qingdao, 266042, China
3 shared publicationsYingkai Gao
Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, MOE, Shandong Provincial Key Laboratory of Biochemical Engineering, Qingdao Nucleic Acid Rapid Detection Engineering Research Center, College of Marine Science and Biological Engineering, Qingdao University of Science and Technology, Qingdao, 266042, China
3 shared publicationsLi Chen
Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, MOE, Shandong Provincial Key Laboratory of Biochemical Engineering, Qingdao Nucleic Acid Rapid Detection Engineering Research Center, College of Marine Science and Biological Engineering, Qingdao University of Science and Technology, Qingdao, 266042, China
2 shared publicationsXintong Yang
Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, MOE, Shandong Provincial Key Laboratory of Biochemical Engineering, Qingdao Nucleic Acid Rapid Detection Engineering Research Center, College of Marine Science and Biological Engineering, Qingdao University of Science and Technology, Qingdao, 266042, China
2 shared publicationsYingying Shan
Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, MOE, Shandong Provincial Key Laboratory of Biochemical Engineering, Qingdao Nucleic Acid Rapid Detection Engineering Research Center, College of Marine Science and Biological Engineering, Qingdao University of Science and Technology, Qingdao, 266042, China
2 shared publicationsFei Li
Biomedical Analysis Center, Army Medical University, Chongqing, 400038, China
1 shared publication
Latest Publications
- 28 March 2024
- Published by Elsevier in Chinese Chemical Letters
- Vol. 35 (10)
A non-peptide-based chymotrypsin-targeted long-wavelength emission fluorescent probe with large Stokes shift and its application in bioimaging
- 28 March 2024
- Published by Elsevier in Chinese Chemical Letters
- Vol. 35 (10)
A non-peptide-based chymotrypsin-targeted long-wavelength emission fluorescent probe with large Stokes shift and its application in bioimaging
- 19 February 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (9) , 3772-3779
New Near-Infrared Fluorescence Imaging Platform with Large Stokes Shift for Carboxylesterase 2 Detection in Thyroid Cancer and Inflammatory Diseases Diagnosis
Development of new near-infrared fluorophores is one of the eternal themes in the field of biosensing and biological imaging. In this work, we constructed a novel fluorophore platform MOR by replacing methylindole of hemicyanine fluorophore (CyR) with benzoxazole to acquire better fluorescence characteristics. Based on the platform, a near infrared (NIR) fluorescent probe MOR-CES2 was synthesized for the specific "off-on" response to carboxylesterase 2 (CES2). The probe exhibited excellent properties including near-infrared emission (735 nm), large Stokes shift (105 nm), high sensitivity (LOD, 0.3 ng/mL), and rapid response (15 min). The successful application of MOR-CES2 in biological imaging of CES2 in mice with thyroid cancer and inflammatory bowel disease demonstrated that the probe could identify cancer cells and tissues and sensitively respond to inflammation. The results proved the potency of MOR-CES2 as an efficient imaging tool to assist in the surgical resection of CES2-related tumors.
- 19 February 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (9) , 3772-3779
New Near-Infrared Fluorescence Imaging Platform with Large Stokes Shift for Carboxylesterase 2 Detection in Thyroid Cancer and Inflammatory Diseases Diagnosis
Development of new near-infrared fluorophores is one of the eternal themes in the field of biosensing and biological imaging. In this work, we constructed a novel fluorophore platform MOR by replacing methylindole of hemicyanine fluorophore (CyR) with benzoxazole to acquire better fluorescence characteristics. Based on the platform, a near infrared (NIR) fluorescent probe MOR-CES2 was synthesized for the specific "off-on" response to carboxylesterase 2 (CES2). The probe exhibited excellent properties including near-infrared emission (735 nm), large Stokes shift (105 nm), high sensitivity (LOD, 0.3 ng/mL), and rapid response (15 min). The successful application of MOR-CES2 in biological imaging of CES2 in mice with thyroid cancer and inflammatory bowel disease demonstrated that the probe could identify cancer cells and tissues and sensitively respond to inflammation. The results proved the potency of MOR-CES2 as an efficient imaging tool to assist in the surgical resection of CES2-related tumors.
- 10 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Fast Feedrate Scheduling and PVT-based High Precision Interpolation for Wire Bonding Operation
With the rapid development of electronic packaging technology and the improvement of electronic integration, chip packaging technology with fine pitch, high density and reliability are highly demanded. For electronic packaging technology, the high-speed wire bonding equipment plays an important role for the high efficiency operation and high quality production. For wire bonding equipment, one of the key issues is to ensure a high-precision tracking trajectory for the wire looping process under high-speed motion. Hence, this paper proposes a novel NURBS interpolator that combines optimal feedrate scheduling and PVT interpolation algorithm to improve the wire looping quality. Firstly, under the consideration of various contour accuracy constraints, a feedrate scheduling model is established based on the fitted NURBS path, and a time-optimized feedrate profile is quickly planned by simplifying the model. In order to improve the interpolation accuracy and simplify the internal operation process of the interpolation, the interpolator is developed by adopting the idea of piecewise fitting, adding derivative constraints at the piecewise points, and using the Lagrange multiplier method to obtain a curve that satisfies the fitting precision. The motion trajectory of each axis is converted into a time-synchronized continuous cubic curve, and then these cubic curves are converted into PVT (position-velocity-time) interpolation instructions according to the principle of Hermitian interpolation. The method in this paper belongs to the curve interpolation method. Even at the corner of the path, the calculated interpolation point can accurately fall on the target path. At the same time, the proposed method can achieve higher contour accuracy with fewer interpolation commands.
- 10 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Fast Feedrate Scheduling and PVT-based High Precision Interpolation for Wire Bonding Operation
With the rapid development of electronic packaging technology and the improvement of electronic integration, chip packaging technology with fine pitch, high density and reliability are highly demanded. For electronic packaging technology, the high-speed wire bonding equipment plays an important role for the high efficiency operation and high quality production. For wire bonding equipment, one of the key issues is to ensure a high-precision tracking trajectory for the wire looping process under high-speed motion. Hence, this paper proposes a novel NURBS interpolator that combines optimal feedrate scheduling and PVT interpolation algorithm to improve the wire looping quality. Firstly, under the consideration of various contour accuracy constraints, a feedrate scheduling model is established based on the fitted NURBS path, and a time-optimized feedrate profile is quickly planned by simplifying the model. In order to improve the interpolation accuracy and simplify the internal operation process of the interpolation, the interpolator is developed by adopting the idea of piecewise fitting, adding derivative constraints at the piecewise points, and using the Lagrange multiplier method to obtain a curve that satisfies the fitting precision. The motion trajectory of each axis is converted into a time-synchronized continuous cubic curve, and then these cubic curves are converted into PVT (position-velocity-time) interpolation instructions according to the principle of Hermitian interpolation. The method in this paper belongs to the curve interpolation method. Even at the corner of the path, the calculated interpolation point can accurately fall on the target path. At the same time, the proposed method can achieve higher contour accuracy with fewer interpolation commands.