Hongbin Xing
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hongbin Xing has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Bo Ye
Kunming University of Science and Technology
2 shared publications - Zhizhen Zhu
The First Military Representative Office of the Chongqing Military Representative Bureau of the Army Equipment Department in Kunming, Kunming 650032, China
2 shared publications - Honggui Cao
Faculty of Information Engineering and Automation, Kunming University of Science and Technology, Kunming 650500, China
1 shared publication - Honggui Cao
Faculty of Information Engineering and Automation, Kunming University of Science and Technology, Kunming 650500, China
1 shared publication - Yangkun Zou
Yunnan Key Laboratory of Intelligent Control and Application, Kunming 650500, China
1 shared publication - Yangkun Zou
Yunnan Key Laboratory of Intelligent Control and Application, Kunming University of Science and Technology, Kunming 650500, China
1 shared publication
Latest Publications
- Open Access
- 28 April 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (9) , 3765
High-Sensitivity Detection of Carbon Fiber-Reinforced Polymer Delamination Using a Novel Eddy Current Probe
The demand for non-destructive testing of carbon fiber-reinforced polymer (CFRP) is becoming increasingly pressing to ensure its safety and reliability across different fields of use. However, the complex structural characteristics and anisotropic bulk conductivity of CFRP make achieving high sensitivity in detecting internal defects such as delamination extremely challenging. To address this issue, a novel triple rectangular coil probe with high sensitivity developed for detecting delamination in CFRP is presented in this paper. A finite element model using COMSOL Multiphysics was developed for CFRP delamination eddy current testing with the designed probe. Based on this model, the probe parameters were determined through orthogonal experiments. By analyzing the eddy current distribution in CFRP samples, the scanning mode was defined. Following this, the detection voltage was evaluated for various delamination parameters, and the sensitivity of different probes was compared. Results indicate that, under the same excitation coil parameters, for a 5 mm delamination lateral dimension change, the single pancake and single rectangular coil probes exhibit sensitivities of 88.24% and 72.55%, respectively, compared with the designed probe. For a 0.5 mm delamination thickness change, their sensitivities are 49.04% and 56.69% of those of the designed probe. The designed probe meets the demand for high-sensitivity detection.
- 28 April 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (9) , 3765
Open AccessHigh-Sensitivity Detection of Carbon Fiber-Reinforced Polymer Delamination Using a Novel Eddy Current Probe
The demand for non-destructive testing of carbon fiber-reinforced polymer (CFRP) is becoming increasingly pressing to ensure its safety and reliability across different fields of use. However, the complex structural characteristics and anisotropic bulk conductivity of CFRP make achieving high sensitivity in detecting internal defects such as delamination extremely challenging. To address this issue, a novel triple rectangular coil probe with high sensitivity developed for detecting delamination in CFRP is presented in this paper. A finite element model using COMSOL Multiphysics was developed for CFRP delamination eddy current testing with the designed probe. Based on this model, the probe parameters were determined through orthogonal experiments. By analyzing the eddy current distribution in CFRP samples, the scanning mode was defined. Following this, the detection voltage was evaluated for various delamination parameters, and the sensitivity of different probes was compared. Results indicate that, under the same excitation coil parameters, for a 5 mm delamination lateral dimension change, the single pancake and single rectangular coil probes exhibit sensitivities of 88.24% and 72.55%, respectively, compared with the designed probe. For a 0.5 mm delamination thickness change, their sensitivities are 49.04% and 56.69% of those of the designed probe. The designed probe meets the demand for high-sensitivity detection.
- Open Access
- 26 April 2024
- Published by MDPI AG in Biosensors
- Vol. 14 (5) , 217
Biplane Enhancement Coil for Magnetic Induction Tomography of Cerebral Hemorrhage
Magnetic Induction Tomography (MIT) is a non-invasive imaging technique used for dynamic monitoring and early screening of cerebral hemorrhage. Currently, there is a significant challenge in cerebral hemorrhage MIT due to weak detection signals, which seriously affects the accuracy of the detection results. To address this issue, a dual-plane enhanced coil was proposed by combining the target field method with consideration of the spatial magnetic field attenuation pattern within the imaging target region. Simulated detection models were constructed using the proposed coil and cylindrical coil as excitation coils, respectively, and simulation imaging tests were conducted using the detection results. The simulation results indicate that compared to the cylindrical coil, the proposed coil enhances the linearity of the magnetic field within the imaging target region by 60.43%. Additionally, it effectively enhances the detection voltage and phase values. The simulation results of hemorrhage detection show that the proposed coil improves the accuracy of hemorrhage detection by 18.26%. It provides more precise detection results, offering a more reliable solution for cerebral hemorrhage localization and detection.
- 26 April 2024
- Published by MDPI AG in Biosensors
- Vol. 14 (5) , 217
Open AccessBiplane Enhancement Coil for Magnetic Induction Tomography of Cerebral Hemorrhage
Magnetic Induction Tomography (MIT) is a non-invasive imaging technique used for dynamic monitoring and early screening of cerebral hemorrhage. Currently, there is a significant challenge in cerebral hemorrhage MIT due to weak detection signals, which seriously affects the accuracy of the detection results. To address this issue, a dual-plane enhanced coil was proposed by combining the target field method with consideration of the spatial magnetic field attenuation pattern within the imaging target region. Simulated detection models were constructed using the proposed coil and cylindrical coil as excitation coils, respectively, and simulation imaging tests were conducted using the detection results. The simulation results indicate that compared to the cylindrical coil, the proposed coil enhances the linearity of the magnetic field within the imaging target region by 60.43%. Additionally, it effectively enhances the detection voltage and phase values. The simulation results of hemorrhage detection show that the proposed coil improves the accuracy of hemorrhage detection by 18.26%. It provides more precise detection results, offering a more reliable solution for cerebral hemorrhage localization and detection.