Ashutosh Richhariya
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ashutosh Richhariya has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
Chandra Sekhar Garudadri
V S T Glaucoma Center, Dr. Kallam Anji Reddy Campus, L. V. Prasad Eye Institute, Hyderabad, Telangana, India
2 shared publications- Sai Naga Sri Harsha Chittajallu
Micro-Mechanics Lab, IIT Hyderabad, Kandi, Sangareddy 502284, India; Prof. Brien Holden Eye Research Centre, L V Prasad Eye Institute, Hyderabad 500034, India
2 shared publications Sanjay Kumar
Engineering Group, Dr. Kallam Anji Reddy campus, L. V. Prasad Eye Institute, Hyderabad, Telangana, India
2 shared publications- Abhilash Goud
Srimati Kannuri Santhamma Centre for Vitreo-Retinal Diseases, L. V. Prasad Eye Institute, Hyderabad, Telangana, India
1 shared publication - Amy L. Lerner
University of Rochester
1 shared publication - Geunyoung Yoon
University of Houston
1 shared publication
Latest Publications
- Open Access
- 29 July 2022
- Published by Medknow in Indian Journal Of Ophthalmology
- Vol. 70 (8) , 2877-2882
Adaptive optics scanning laser ophthalmoscopy may support early diagnosis of glaucoma
Purpose: To compare image characteristics of retinal nerve fiber layer (RNFL) between glaucoma patients and healthy controls using adaptive optics scanning laser ophthalmoscopy (AOSLO). Methods: This was a cross-sectional pilot study with two groups: a glaucoma group with patients with moderate or severe glaucoma as per the Hodapp–Parrish–Anderson classification system and a control group with healthy individuals. The optic nerve damage in moderate glaucoma was predominantly located in only one hemisphere; the other hemisphere was un- or minimally affected on optical coherence tomography and automated perimetry and is referred to as early glaucoma. The structure of RNFL bundles and gain (%) in RNFL images with mean pixel values between 15 and 35 were analyzed. Imaging was performed one degree away from the optic disc margin at two and four cardinal clock positions in the glaucoma and control groups, respectively. The field of view was 1.3° at 2.3 m resolution. We studied one eye per participant. Results: There were 11 glaucoma patients and 7 healthy controls. Imaging was successful at 88% of the locations in controls and early glaucoma; the reflectivity differed significantly (0.51 and 0.56, respectively, P < 0.001) but not the structure of RNFL bundles (Cohen’s Kappa 0.11) between them. In patients with moderate and severe glaucoma, imaging was successful only at 46% of the locations; RNFL bundles were not discernible, and RNFL reflectivity did not differ from those with early glaucoma (P < 0.11). Conclusion: The recorded gain (%) of RNFL images obtained using AOSLO could be an objective indicator of early glaucoma.
- 29 July 2022
- Published by Medknow in Indian Journal Of Ophthalmology
- Vol. 70 (8) , 2877-2882
Open AccessAdaptive optics scanning laser ophthalmoscopy may support early diagnosis of glaucoma
Purpose: To compare image characteristics of retinal nerve fiber layer (RNFL) between glaucoma patients and healthy controls using adaptive optics scanning laser ophthalmoscopy (AOSLO). Methods: This was a cross-sectional pilot study with two groups: a glaucoma group with patients with moderate or severe glaucoma as per the Hodapp–Parrish–Anderson classification system and a control group with healthy individuals. The optic nerve damage in moderate glaucoma was predominantly located in only one hemisphere; the other hemisphere was un- or minimally affected on optical coherence tomography and automated perimetry and is referred to as early glaucoma. The structure of RNFL bundles and gain (%) in RNFL images with mean pixel values between 15 and 35 were analyzed. Imaging was performed one degree away from the optic disc margin at two and four cardinal clock positions in the glaucoma and control groups, respectively. The field of view was 1.3° at 2.3 m resolution. We studied one eye per participant. Results: There were 11 glaucoma patients and 7 healthy controls. Imaging was successful at 88% of the locations in controls and early glaucoma; the reflectivity differed significantly (0.51 and 0.56, respectively, P < 0.001) but not the structure of RNFL bundles (Cohen’s Kappa 0.11) between them. In patients with moderate and severe glaucoma, imaging was successful only at 46% of the locations; RNFL bundles were not discernible, and RNFL reflectivity did not differ from those with early glaucoma (P < 0.11). Conclusion: The recorded gain (%) of RNFL images obtained using AOSLO could be an objective indicator of early glaucoma.
- Open Access
- 10 January 2022
- Published by MDPI AG in Bioengineering
- Vol. 9 (1) , 26
A Review on Damage and Rupture Modelling for Soft Tissues
Computational modelling of damage and rupture of non-connective and connective soft tissues due to pathological and supra-physiological mechanisms is vital in the fundamental understanding of failures. Recent advancements in soft tissue damage models play an essential role in developing artificial tissues, medical devices/implants, and surgical intervention practices. The current article reviews the recently developed damage models and rupture models that considered the microstructure of the tissues. Earlier review works presented damage and rupture separately, wherein this work reviews both damage and rupture in soft tissues. Wherein the present article provides a detailed review of various models on the damage evolution and tear in soft tissues focusing on key conceptual ideas, advantages, limitations, and challenges. Some key challenges of damage and rupture models are outlined in the article, which helps extend the present damage and rupture models to various soft tissues.
- 10 January 2022
- Published by MDPI AG in Bioengineering
- Vol. 9 (1) , 26
Open AccessA Review on Damage and Rupture Modelling for Soft Tissues
Computational modelling of damage and rupture of non-connective and connective soft tissues due to pathological and supra-physiological mechanisms is vital in the fundamental understanding of failures. Recent advancements in soft tissue damage models play an essential role in developing artificial tissues, medical devices/implants, and surgical intervention practices. The current article reviews the recently developed damage models and rupture models that considered the microstructure of the tissues. Earlier review works presented damage and rupture separately, wherein this work reviews both damage and rupture in soft tissues. Wherein the present article provides a detailed review of various models on the damage evolution and tear in soft tissues focusing on key conceptual ideas, advantages, limitations, and challenges. Some key challenges of damage and rupture models are outlined in the article, which helps extend the present damage and rupture models to various soft tissues.
- Open Access
- 1 November 2020
- Published by Scientific Scholar in Indian Journal of Medical Research
- Vol. 152 (Suppl 1) , S252-S253
Microscopic image of the fovea in a patient with choroiditis
Indian J Med Res, Official publication of Indian Council of Medical Research,India
- 1 November 2020
- Published by Scientific Scholar in Indian Journal of Medical Research
- Vol. 152 (Suppl 1) , S252-S253
Open AccessMicroscopic image of the fovea in a patient with choroiditis
Indian J Med Res, Official publication of Indian Council of Medical Research,India
- Open Access
- 1 May 2018
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 7 (3) , 19
Is Ahmed Glaucoma Valve Consistent in Performance?
Purpose: To investigate the mechanism of action and consistency in flow characteristics of the Ahmed glaucoma valve (AGV) under simulated physiological conditions in-vitro and to evaluate whether resistance during priming has any effect on performance of the device. Methods: Each newly opened AGV device was connected to a digital manometer and was primed with normal saline. The device was then placed in a saline bath and connected to an open manometer, a digital manometer, and an infusion pump. Saline was infused at a rate of 3 μL/min for 24 hours. Digital manometer readings were recorded at 4 Hz. Results: Data obtained from 9 devices are presented as medians (ranges). The priming pressure was 1130 (835, 1625) mm Hg. Pressure versus time curves showed two distinct phases; transient and steady phases. The transient phase peak pressure was 24 (13, 45) mm Hg. In the steady phase, opening and closing pressures were 13 (10, 17) and 7 (4, 9) mm Hg, respectively; the valve leaflets briefly opened every 73.9 (51, 76.6) minutes and the fluctuation of pressure (difference between opening and closing pressures) was 6 (3, 9) mm Hg. The Spearman correlation coefficient between priming and opening and priming and closing pressure was ρ = −0.13 (P = 0.72) and ρ = −0.36 (P = 0.33), respectively. Conclusions: The device showed functionality like a valve. The resistance during priming did not affect opening and closing pressures of the AGV. This study showed variable in vitro performance of the AGV. Translational Relevance: These laboratory findings might, at least partly, explain the variability in the clinical outcome of the device.
- 1 May 2018
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 7 (3) , 19
Open AccessIs Ahmed Glaucoma Valve Consistent in Performance?
Purpose: To investigate the mechanism of action and consistency in flow characteristics of the Ahmed glaucoma valve (AGV) under simulated physiological conditions in-vitro and to evaluate whether resistance during priming has any effect on performance of the device. Methods: Each newly opened AGV device was connected to a digital manometer and was primed with normal saline. The device was then placed in a saline bath and connected to an open manometer, a digital manometer, and an infusion pump. Saline was infused at a rate of 3 μL/min for 24 hours. Digital manometer readings were recorded at 4 Hz. Results: Data obtained from 9 devices are presented as medians (ranges). The priming pressure was 1130 (835, 1625) mm Hg. Pressure versus time curves showed two distinct phases; transient and steady phases. The transient phase peak pressure was 24 (13, 45) mm Hg. In the steady phase, opening and closing pressures were 13 (10, 17) and 7 (4, 9) mm Hg, respectively; the valve leaflets briefly opened every 73.9 (51, 76.6) minutes and the fluctuation of pressure (difference between opening and closing pressures) was 6 (3, 9) mm Hg. The Spearman correlation coefficient between priming and opening and priming and closing pressure was ρ = −0.13 (P = 0.72) and ρ = −0.36 (P = 0.33), respectively. Conclusions: The device showed functionality like a valve. The resistance during priming did not affect opening and closing pressures of the AGV. This study showed variable in vitro performance of the AGV. Translational Relevance: These laboratory findings might, at least partly, explain the variability in the clinical outcome of the device.
- 17 February 2018
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 21 (3) , 287-296
Sensitivity of corneal biomechanical and optical behavior to material parameters using design of experiments method
The optical performance of the human cornea under intraocular pressure (IOP) is the result of complex material properties and their interactions. The measurement of the numerous material parameters that define this material behavior may be key in the refinement of patient-specific models. The goal of this study was to investigate the relative contribution of these parameters to the biomechanical and optical responses of human cornea predicted by a widely accepted anisotropic hyperelastic finite element model, with regional variations in the alignment of fibers. Design of experiments methods were used to quantify the relative importance of material properties including matrix stiffness, fiber stiffness, fiber nonlinearity and fiber dispersion under physiological IOP. Our sensitivity results showed that corneal apical displacement was influenced nearly evenly by matrix stiffness, fiber stiffness and nonlinearity. However, the variations in corneal optical aberrations (refractive power and spherical aberration) were primarily dependent on the value of the matrix stiffness. The optical aberrations predicted by variations in this material parameter were sufficiently large to predict clinically important changes in retinal image quality. Therefore, well-characterized individual variations in matrix stiffness could be critical in cornea modeling in order to reliably predict optical behavior under different IOPs or after corneal surgery.
- 17 February 2018
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 21 (3) , 287-296
Sensitivity of corneal biomechanical and optical behavior to material parameters using design of experiments method
The optical performance of the human cornea under intraocular pressure (IOP) is the result of complex material properties and their interactions. The measurement of the numerous material parameters that define this material behavior may be key in the refinement of patient-specific models. The goal of this study was to investigate the relative contribution of these parameters to the biomechanical and optical responses of human cornea predicted by a widely accepted anisotropic hyperelastic finite element model, with regional variations in the alignment of fibers. Design of experiments methods were used to quantify the relative importance of material properties including matrix stiffness, fiber stiffness, fiber nonlinearity and fiber dispersion under physiological IOP. Our sensitivity results showed that corneal apical displacement was influenced nearly evenly by matrix stiffness, fiber stiffness and nonlinearity. However, the variations in corneal optical aberrations (refractive power and spherical aberration) were primarily dependent on the value of the matrix stiffness. The optical aberrations predicted by variations in this material parameter were sufficiently large to predict clinically important changes in retinal image quality. Therefore, well-characterized individual variations in matrix stiffness could be critical in cornea modeling in order to reliably predict optical behavior under different IOPs or after corneal surgery.
- Open Access
- 20 September 2017
- Published by Springer Nature in BMC Ophthalmology
- Vol. 17 (1) , 172
Semi-automated quantification of hard exudates in colour fundus photographs diagnosed with diabetic retinopathy
Hard exudates (HEs) are the classical sign of diabetic retinopathy (DR) which is one of the leading causes of blindness, especially in developing countries. Accordingly, disease screening involves examining HEs qualitatively using fundus camera. However, for monitoring the treatment response, quantification of HEs becomes crucial and hence clinicians now seek to measure the area of HEs in the digital colour fundus (CF) photographs. Against this backdrop, we proposed an algorithm to quantify HEs using CF images and compare with previously reported technique using ImageJ. CF photographs of 30 eyes (20 patients) with diabetic macular edema were obtained. A robust semi-automated algorithm was developed to quantify area covered by HEs. In particular, the proposed algorithm, a two pronged methodology, involved performing top-hat filtering, second order statistical filtering, and thresholding of the colour fundus images. Subsequently, two masked observers performed HEs measurements using previously reported ImageJ-based protocol and compared with those obtained through proposed method. Intra and inter-observer grading was performed for determining percentage area of HEs identified by the individual algorithm. Of the 30 subjects, 21 were males and 9 were females with a mean age of the 50.25 ± 7.80 years (range 33–66 years). The correlation between the two measurements of semi-automated and ImageJ were 0.99 and 0.99 respectively. Previously reported method detected only 0–30% of the HEs area in 9 images, 30–60% in 12 images and 60–90% in remaining images, and more than 90% in none. In contrast, proposed method, detected 60–90% of the HEs area in 13 images and 90–100% in remaining 17 images. Proposed method semi-automated algorithm achieved acceptable accuracy, qualitatively and quantitatively, on a heterogeneous dataset. Further, quantitative analysis performed based on intra- and inter-observer grading showed that proposed methodology detects HEs more accurately than previously reported ImageJ-based technique. In particular, we proposed algorithm detect faint HEs also as opposed to the earlier method.
- 20 September 2017
- Published by Springer Nature in BMC Ophthalmology
- Vol. 17 (1) , 172
Open AccessSemi-automated quantification of hard exudates in colour fundus photographs diagnosed with diabetic retinopathy
Hard exudates (HEs) are the classical sign of diabetic retinopathy (DR) which is one of the leading causes of blindness, especially in developing countries. Accordingly, disease screening involves examining HEs qualitatively using fundus camera. However, for monitoring the treatment response, quantification of HEs becomes crucial and hence clinicians now seek to measure the area of HEs in the digital colour fundus (CF) photographs. Against this backdrop, we proposed an algorithm to quantify HEs using CF images and compare with previously reported technique using ImageJ. CF photographs of 30 eyes (20 patients) with diabetic macular edema were obtained. A robust semi-automated algorithm was developed to quantify area covered by HEs. In particular, the proposed algorithm, a two pronged methodology, involved performing top-hat filtering, second order statistical filtering, and thresholding of the colour fundus images. Subsequently, two masked observers performed HEs measurements using previously reported ImageJ-based protocol and compared with those obtained through proposed method. Intra and inter-observer grading was performed for determining percentage area of HEs identified by the individual algorithm. Of the 30 subjects, 21 were males and 9 were females with a mean age of the 50.25 ± 7.80 years (range 33–66 years). The correlation between the two measurements of semi-automated and ImageJ were 0.99 and 0.99 respectively. Previously reported method detected only 0–30% of the HEs area in 9 images, 30–60% in 12 images and 60–90% in remaining images, and more than 90% in none. In contrast, proposed method, detected 60–90% of the HEs area in 13 images and 90–100% in remaining 17 images. Proposed method semi-automated algorithm achieved acceptable accuracy, qualitatively and quantitatively, on a heterogeneous dataset. Further, quantitative analysis performed based on intra- and inter-observer grading showed that proposed methodology detects HEs more accurately than previously reported ImageJ-based technique. In particular, we proposed algorithm detect faint HEs also as opposed to the earlier method.