Diya Wen
Research Subjects
Diya Wen has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Di Pan
State Key Laboratory of NBC Protection for Civilian, Beijing 102205, China
2 shared publications - Hua Song
State Key Laboratory of NBC Protection for Civilian, Beijing 102205, China
2 shared publications - Shupei Bai
State Key Laboratory of NBC Protection for Civilian, Beijing 102205, China
2 shared publications - Xuan Guo
State Key Laboratory of Chemistry for NBC Hazards Protection, Chemical Defense Institute, Academy of Military Science, Beijing, China
2 shared publications - Hao Han
State Key Laboratory of NBC Protection for Civilian, Beijing 102205, China
1 shared publication - Min Tang
School of Light Industry and Engineering, South China University of Technology, Guangzhou 510641, China
1 shared publication
Latest Publications
- Open Access
Factors Influencing the Sterilization of E. coli in a High-Voltage Electric Field: Electric Field Strength, Temperature and Humidity
The application of a high-voltage electric field (HVEF) is crucial for mitigating the growth and reproduction of pathogenic microorganisms on solid surfaces. However, the electric field distribution of HVEF in the undischarged state and bactericidal effect remain largely unexplored. Herein, a unipolar wire–plate HVEF device was developed and its field strength distribution was simulated by COMOSL software (version 6.2). The simulation analysis revealed that the electric field strength and space charge density of HVEF in the undischarged state reached a maximum at the discharge electrode and a minimum at the middle of the two electrode wires. The electric field strength and the inhomogeneity of electric intensity distribution also decreased with the increase in electrode spacing. The sterilization effect of E. coli was positively correlated with voltage and treatment time, but negatively correlated with electrode spacing, which was consistent with the change in the field strength of the simulation results. When the voltage was −12.5 kv and electrode spacing 2.7 cm, the sterilization rate was 98.03% at 60 min. In addition, the increase in treatment temperature and relative humidity also affected the electric field distribution, thereby improving the bactericidal effect. Our results revealed that the electric field distribution was the main factor affecting the sterilization effect of HVEF, which provided theoretical support for the design of HVEF sterilization equipment and the optimization of sterilization performance
Open AccessFactors Influencing the Sterilization of E. coli in a High-Voltage Electric Field: Electric Field Strength, Temperature and Humidity
The application of a high-voltage electric field (HVEF) is crucial for mitigating the growth and reproduction of pathogenic microorganisms on solid surfaces. However, the electric field distribution of HVEF in the undischarged state and bactericidal effect remain largely unexplored. Herein, a unipolar wire–plate HVEF device was developed and its field strength distribution was simulated by COMOSL software (version 6.2). The simulation analysis revealed that the electric field strength and space charge density of HVEF in the undischarged state reached a maximum at the discharge electrode and a minimum at the middle of the two electrode wires. The electric field strength and the inhomogeneity of electric intensity distribution also decreased with the increase in electrode spacing. The sterilization effect of E. coli was positively correlated with voltage and treatment time, but negatively correlated with electrode spacing, which was consistent with the change in the field strength of the simulation results. When the voltage was −12.5 kv and electrode spacing 2.7 cm, the sterilization rate was 98.03% at 60 min. In addition, the increase in treatment temperature and relative humidity also affected the electric field distribution, thereby improving the bactericidal effect. Our results revealed that the electric field distribution was the main factor affecting the sterilization effect of HVEF, which provided theoretical support for the design of HVEF sterilization equipment and the optimization of sterilization performance
- Open Access
Enhancing Escherichia coli Inactivation: Synergistic Mechanism of Ultraviolet Light and High-Voltage Electric Field
This study investigated the bactericidal effects of ultraviolet (UV) radiation, a high-voltage electric field (HVEF), and their combination on Escherichia coli. The results indicated that UV and combined disinfection were more effective with longer exposure, leading to significant reductions in microbial activity. Specifically, the single UV disinfection alone reduced activity by 3.3 log after 5 min, while combined disinfection achieved a 4.2 log reduction. In contrast, short-term HVEF treatment did not exhibit significant bactericidal effects, only achieving a reduction of 0.17 log in 5 min. Furthermore, prolonged exposure to both UV disinfection and an HVEF was found to damage cell membranes, ultimately causing cell death, while shorter durations did not. Despite rapid cell count decreases, flow cytometry did not detect apoptotic or necrotic cells, likely due to rapid cell rupture. This study suggests that combining UV radiation and an HVEF could be a promising approach for inhibiting bacterial reproduction, with HVEF enhancing UV effects. These findings provide insights for using combined HVEF and UV disinfection in food safety and preservation.
Open AccessEnhancing Escherichia coli Inactivation: Synergistic Mechanism of Ultraviolet Light and High-Voltage Electric Field
This study investigated the bactericidal effects of ultraviolet (UV) radiation, a high-voltage electric field (HVEF), and their combination on Escherichia coli. The results indicated that UV and combined disinfection were more effective with longer exposure, leading to significant reductions in microbial activity. Specifically, the single UV disinfection alone reduced activity by 3.3 log after 5 min, while combined disinfection achieved a 4.2 log reduction. In contrast, short-term HVEF treatment did not exhibit significant bactericidal effects, only achieving a reduction of 0.17 log in 5 min. Furthermore, prolonged exposure to both UV disinfection and an HVEF was found to damage cell membranes, ultimately causing cell death, while shorter durations did not. Despite rapid cell count decreases, flow cytometry did not detect apoptotic or necrotic cells, likely due to rapid cell rupture. This study suggests that combining UV radiation and an HVEF could be a promising approach for inhibiting bacterial reproduction, with HVEF enhancing UV effects. These findings provide insights for using combined HVEF and UV disinfection in food safety and preservation.