Zhen Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zhen Li has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
Liang Chen
Key Laboratory for Thermal Science and Power Engineering of Ministry of Education, Department of Engineering Mechanics, Tsinghua University, Beijing, China
3 shared publicationsLu Wang
Key Laboratory for Thermal Science and Power Engineering of Ministry of Education, Department of Engineering Mechanics, Tsinghua University, Beijing, China
3 shared publicationsXinyi Wang
Key Laboratory for Thermal Science and Power Engineering of Ministry of Education, Department of Engineering Mechanics, Tsinghua University, Beijing, China
3 shared publicationsBo Zhang
Key Laboratory for Thermal Science and Power Engineering of Ministry of Education, Department of Engineering Mechanics, Tsinghua University, Beijing, China
2 shared publicationsXiaoxuan Chen
Key Laboratory for Thermal Science and Power Engineering of Ministry of Education, Department of Engineering Mechanics, Tsinghua University, Beijing, China
2 shared publicationsXing Zhang
Key Laboratory of Thermal Science and Power Engineering of Ministry of Education, Department of Engineering Mechanics, Tsinghua University, Beijing, China
2 shared publications
Latest Publications
- Open Access
- 23 November 2026
- Published by Caravel Press
- Vol. 22, 258-270
Parametric Characterisation and Operating Boundaries of Air- and Liquid-Cooling Architectures in High-Density Data Centres
The rapid growth of artificial intelligence has continuously increased chip and rack power densities, making thermal management an increasingly important factor in both the cooling capability and energy efficiency of data centres. Improving heat transfer efficiency can reduce the temperature difference required for heat rejection and potentially decrease the dependence on energy-intensive mechanical cooling. However, comparisons among air cooling, cold-plate cooling, and immersion cooling are often affected by simultaneous differences in coolant properties, package structures, heat-sink dimensions, and cooling-source temperatures. In this study, a unified chip-to-facility thermal resistance framework was developed to compare rack-level air cooling, single-phase lidded cold-plate cooling, single-phase Direct-to-Die cold-plate cooling, and single-phase immersion cooling. Under unified geometric conditions with a common fin height of 20 mm, the total thermal resistance of the liquid-cooling architectures was only 24.2%–37.5% of that of air cooling. The dominant thermal resistance also shifted substantially among different architectures. Air cooling was mainly limited by the heat sink, heat exchanger, and airflow warming and mixing processes, whereas thermal interface materials and heat spreading within the base plate became increasingly important for liquid cooling. Architecture-specific enhancement strategies were therefore introduced by improving thermal interface materials, heat-spreading structures, and heat-sink dimensions. At the adopted coolant-velocity modelling upper bounds and a facility-water inlet temperature of 10 °C, the second-generation configurations achieved maximum single-chip cooling capacities of 1.74, 4.43, 6.09, and 6.34 kW for air cooling, lidded cold-plate cooling, Direct-to-Die cold-plate cooling, and immersion cooling, respectively. The results demonstrated that different cooling architectures required different enhancement pathways. Reducing thermal resistance not only increased the achievable cooling capacity but also provided greater flexibility for integrating free-cooling sources and reducing reliance on mechanical refrigeration, supporting the development of more sustainable high-density data centres.
- 23 November 2026
- Published by Caravel Press
- Vol. 22, 258-270
Open AccessParametric Characterisation and Operating Boundaries of Air- and Liquid-Cooling Architectures in High-Density Data Centres
The rapid growth of artificial intelligence has continuously increased chip and rack power densities, making thermal management an increasingly important factor in both the cooling capability and energy efficiency of data centres. Improving heat transfer efficiency can reduce the temperature difference required for heat rejection and potentially decrease the dependence on energy-intensive mechanical cooling. However, comparisons among air cooling, cold-plate cooling, and immersion cooling are often affected by simultaneous differences in coolant properties, package structures, heat-sink dimensions, and cooling-source temperatures. In this study, a unified chip-to-facility thermal resistance framework was developed to compare rack-level air cooling, single-phase lidded cold-plate cooling, single-phase Direct-to-Die cold-plate cooling, and single-phase immersion cooling. Under unified geometric conditions with a common fin height of 20 mm, the total thermal resistance of the liquid-cooling architectures was only 24.2%–37.5% of that of air cooling. The dominant thermal resistance also shifted substantially among different architectures. Air cooling was mainly limited by the heat sink, heat exchanger, and airflow warming and mixing processes, whereas thermal interface materials and heat spreading within the base plate became increasingly important for liquid cooling. Architecture-specific enhancement strategies were therefore introduced by improving thermal interface materials, heat-spreading structures, and heat-sink dimensions. At the adopted coolant-velocity modelling upper bounds and a facility-water inlet temperature of 10 °C, the second-generation configurations achieved maximum single-chip cooling capacities of 1.74, 4.43, 6.09, and 6.34 kW for air cooling, lidded cold-plate cooling, Direct-to-Die cold-plate cooling, and immersion cooling, respectively. The results demonstrated that different cooling architectures required different enhancement pathways. Reducing thermal resistance not only increased the achievable cooling capacity but also provided greater flexibility for integrating free-cooling sources and reducing reliance on mechanical refrigeration, supporting the development of more sustainable high-density data centres.
- 23 June 2026
- Published by Springer Nature in Science China Technological Sciences
- Vol. 69 (9) , 1920108
Performance evaluation of new water evaporation electricity generation devices based on binary oxide nanoparticles
- 23 June 2026
- Published by Springer Nature in Science China Technological Sciences
- Vol. 69 (9) , 1920108
Performance evaluation of new water evaporation electricity generation devices based on binary oxide nanoparticles
- 5 May 2025
- Published by Springer Nature in Journal of Thermal Science
- Vol. 34 (3) , 1129-1147
Activate Radiative Cooling Technology for Data Center Cooling and Energy Efficiency Analysis
- 5 May 2025
- Published by Springer Nature in Journal of Thermal Science
- Vol. 34 (3) , 1129-1147
Activate Radiative Cooling Technology for Data Center Cooling and Energy Efficiency Analysis
- 13 December 2024
- Published by Springer Nature in Journal of Thermal Science
- Vol. 34 (2) , 413-428
Energy Conversion and Transmission of Electric Power Generation through Water Evaporation
- 13 December 2024
- Published by Springer Nature in Journal of Thermal Science
- Vol. 34 (2) , 413-428
Energy Conversion and Transmission of Electric Power Generation through Water Evaporation
- 8 April 2024
- Published by Elsevier in Energy and Buildings
- Vol. 311
Combining physical laws and ANN for predicting energy consumption of data center cooling systems
- 8 April 2024
- Published by Elsevier in Energy and Buildings
- Vol. 311
Combining physical laws and ANN for predicting energy consumption of data center cooling systems
- Open Access
- 31 October 2017
- Published by Oxford University Press (OUP) in International Journal of Low-Carbon Technologies
- Vol. 13 (1) , 1-5
A novel flue gas heat recovery system based on low-pressure regeneration liquid desiccant cycle
Flue gas from natural gas boilers contains much water vapor, so the latent heat occupies a large proportion of the total waste heat. This paper introduces a flue gas driven absorption system based on low-pressure regeneration liquid cycle to recover water and waste heat, especially the latent heat. The concentrated liquid desiccant is sprayed into the packed tower to absorb the vapor from the low-temperature flue gas and gets diluted itself. Then the diluted desiccant is heated and concentrated by the high-temperature flue gas in the vacuum regenerator. The evaporated water from the regenerator then releases condensation heat to the return water of the heating network. Based on the thermodynamic model of the new system, the simulation results show that the flue gas (200°C, 120 g/kg) is eventually released to the atmosphere at 53°C with a humidity ratio of 46 g/kg, which means considerable heat is recovered by the system. The heat and water recovery of the new system is not constrained by the dew point of the flue gas. It also lowers the requirement of the generation temperature due to vacuum regeneration. So in terms of heat recovery, the new system outperforms the traditional condensing system and the open-cycle absorption system by 28.3% and 23.1%, respectively. The new system also helps to reduce particulate emissions and recover water, with a recovery of 0.36 tons of water per hour according to the simulation result based on the boiler with a power of 2.8 MW.
- 31 October 2017
- Published by Oxford University Press (OUP) in International Journal of Low-Carbon Technologies
- Vol. 13 (1) , 1-5
Open AccessA novel flue gas heat recovery system based on low-pressure regeneration liquid desiccant cycle
Flue gas from natural gas boilers contains much water vapor, so the latent heat occupies a large proportion of the total waste heat. This paper introduces a flue gas driven absorption system based on low-pressure regeneration liquid cycle to recover water and waste heat, especially the latent heat. The concentrated liquid desiccant is sprayed into the packed tower to absorb the vapor from the low-temperature flue gas and gets diluted itself. Then the diluted desiccant is heated and concentrated by the high-temperature flue gas in the vacuum regenerator. The evaporated water from the regenerator then releases condensation heat to the return water of the heating network. Based on the thermodynamic model of the new system, the simulation results show that the flue gas (200°C, 120 g/kg) is eventually released to the atmosphere at 53°C with a humidity ratio of 46 g/kg, which means considerable heat is recovered by the system. The heat and water recovery of the new system is not constrained by the dew point of the flue gas. It also lowers the requirement of the generation temperature due to vacuum regeneration. So in terms of heat recovery, the new system outperforms the traditional condensing system and the open-cycle absorption system by 28.3% and 23.1%, respectively. The new system also helps to reduce particulate emissions and recover water, with a recovery of 0.36 tons of water per hour according to the simulation result based on the boiler with a power of 2.8 MW.
- 17 March 2016
- Published by Springer Nature in Building Simulation
- Vol. 9 (5) , 541-550
Study of hot air recirculation and thermal management in data centers by using temperature rise distribution
- 17 March 2016
- Published by Springer Nature in Building Simulation
- Vol. 9 (5) , 541-550
Study of hot air recirculation and thermal management in data centers by using temperature rise distribution
- 9 September 2014
- Published by Springer Nature
- p. 609-620
Application of Heat Pipe System in Data Center Cooling
- 9 September 2014
- Published by Springer Nature
- p. 609-620
Application of Heat Pipe System in Data Center Cooling
- 22 January 2014
- Published by Springer Nature in Chinese Science Bulletin
- Vol. 59 (5-6) , 571-576
Experimental studies on overall property of thermoelectric modules with sandwiched structures
- 22 January 2014
- Published by Springer Nature in Chinese Science Bulletin
- Vol. 59 (5-6) , 571-576
Experimental studies on overall property of thermoelectric modules with sandwiched structures
- 11 May 2012
- Published by Springer Nature in Science China Technological Sciences
- Vol. 55 (8) , 2126-2131
Entransy dissipation analysis and optimization of separated heat pipe system
- 11 May 2012
- Published by Springer Nature in Science China Technological Sciences
- Vol. 55 (8) , 2126-2131
Entransy dissipation analysis and optimization of separated heat pipe system