GHGuoliang Huang

Guoliang Huang

*This is an algorithmically generated author record based on publicly available information.

Guoliang Huang has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Research on Stability of Transmission Tower Slopes with Different Slope Ratios Under Rainfall Conditions and Reinforcement Effects of Anti-Slide Piles

    by Guoliang Huang, Xiaolong Huang, Caiyan Lin, Ji Shi, Xiongwu Tao, Jiaxiang Lin, Bingxiang Yuan

    With the extensive construction of high-voltage power grid projects in complex mountainous terrains, rainfall-induced slope instability poses a significant threat to the safety of transmission tower foundations. This study focuses on a power transmission and transformation project in Huizhou City, Guangdong Province. Using MIDAS GTS NX 2019 (v1.2), an unsaturated seepage-mechanics coupling model was established to systematically investigate the influence of slope ratios (1:0.75, 1:1, and 1:1.25) on slope stability under rainfall conditions and the reinforcement effects of anti-slide piles. The results demonstrate that slope ratios significantly govern slope responses. For steep slopes (1:0.75), post-rainfall matrix suction loss reached 43.2%, peak displacement attained 74.49 mm, and the safety factor decreased by 12.5%. In contrast, gentle slopes (1:1.25) exhibited superior stability. Anti-slide piles effectively controlled displacement growth (≤9.15%), but pile bending moments increased markedly with steeper slope ratios, accompanied by a notable expansion of the plastic zone at the slope toe. The study reveals a destabilization mechanism characterized by “seepage–strength degradation–displacement synergy” and recommends engineering practices adopting slope ratios of 1:1–1:1.25, combined with anti-slide piles (spacing ≤ 1.5 m) and dynamic drainage measures. These findings provide critical guidance for the design of transmission tower slopes in mountainous regions.


  • Open Access

    A Sustainable Steel-GFRP Composite Bars Reinforced Concrete Structure: Investigation of the Bonding Performance

    by Guoliang Huang, Ji Shi, Wenzhuo Lian, Linbo Hong, Shuzhuo Zhi, Jialing Yang, Caiyan Lin, Junhong Zhou, Shuhua Xiao

    Steel-fiber reinforced polymer (FRP) composite bars (SFCBs) can enhance the controllability of damage in concrete structures; thus, studying the interfacial bonding between them is fundamental and a prerequisite for achieving deformation coordination and collaboration. However, research on the interfacial bonding performance between SFCBs and concrete remains inadequate. This study conducted central pullout tests on SFCB-concrete specimens with different concrete strengths (C30, C50, and C70), bar diameters (12, 16 and 20 mm), and hoop reinforcement constraints, analyzing variations in failure modes, bond-slip curves, bond strength, etc. Additionally, finite element simulations were performed using ABAQUS software to further validate the bonding mechanism of SFCB-concrete. The results showed that the failure mode of the specimens was related to the confinement effect on the bars. Insufficient concrete cover and lack of hoop restraint led to splitting failure, whereas pullout failure occurred otherwise. For the specimens with pullout failure, the interfacial damage between the SFCB and concrete was mainly caused by the surface fibers wear of the bar and the shear of the concrete lugs, which indicated that the bond of the SFCB-concrete interface consisted mainly of mechanical interlocking forces. In addition, the variation of concrete strength as well as bar diameter did not affect the bond-slip relationship of SFCB-concrete. However, the bond strength of SFCB-concrete increased with the increase of concrete strength. For example, compared with C30 concrete, when the concrete strength was increased to C70, the bond strength of the specimens under the same conditions was increased to 50–101.6%. In contrast, the bond strength of the specimens decreased by 13.29–28.71% when the bar diameter was increased from 12 to 14 mm. These discoveries serve as valuable references for the implementation of sustainable SFCB-reinforced concrete structures.