HZHao Zhou

Hao Zhou

*This is an algorithmically generated author record based on publicly available information.

Hao Zhou has a total of 16 co-authors. Here are the top co-authors by number of shared publications:

  • Yao He

    State Key Laboratory of Ophthalmology, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China

    2 shared publications
  • Zhi Xie

    State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China

    2 shared publications
  • Jianxiang Deng

    State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-Sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangzhou, China

    1 shared publication
  • Jing Li

    Department of Ophthalmology, Guangdong Women and Children Hospital, Guangzhou 511400, China

    1 shared publication
  • Li Huang

    State Key Laboratory of Ophthalmology, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou 510060, China

    1 shared publication
  • Limei Sun

    State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Sun Yat-Sen University, Guangzhou, China

    1 shared publication

Latest Publications

  • Open Access

    DCKD: Distribution-Corrected Knowledge Distillation for Enhanced Industrial Defect Detection

    by Weidong Du, Hao Zhou

    Deploying deep learning models for industrial defect detection is challenging, as smaller models lack precision and larger models require significant computational resources. To address this, knowledge distillation has been used to transfer knowledge from a larger teacher model to a smaller student model, though its effectiveness is limited by inaccurate teacher predictions and inadequate handling of difficult samples. In this paper, a novel method, Distribution-Corrected Knowledge Distillation (DCKD), is proposed to overcome these issues. A Logits Distribution Correction (LDC) Module is introduced to correct inaccuracies in the teacher model’s predictions, and an Iterative Hard Sample Aggregation (IHA) Module is used to enhance the student model’s ability to handle challenging cases. This approach significantly improves detection accuracy across multiple industrial datasets, surpassing state-of-the-art distillation techniques. Notably, the student model outperforms the teacher model on the NEU and CG-DF datasets, with mAP scores improving from 0.766 and 0.716 to 0.794 and 0.747, respectively.

  • Open Access

    An Interpretable System for Screening the Severity Level of Retinopathy in Premature Infants Using Deep Learning

    by Wenhan Yang, Hao Zhou, Yun Zhang, Limei Sun, Li Huang, Songshan Li, Xiaoling Luo, Yili Jin, Wei Sun, Wenjia Yan, et al.

    Accurate evaluation of retinopathy of prematurity (ROP) severity is vital for screening and proper treatment. Current deep-learning-based automated AI systems for assessing ROP severity do not follow clinical guidelines and are opaque. The aim of this study is to develop an interpretable AI system by mimicking the clinical screening process to determine ROP severity level. A total of 6100 RetCam Ⅲ wide-field digital retinal images were collected from Guangdong Women and Children Hospital at Panyu (PY) and Zhongshan Ophthalmic Center (ZOC). A total of 3330 images of 520 pediatric patients from PY were annotated to train an object detection model to detect lesion type and location. A total of 2770 images of 81 pediatric patients from ZOC were annotated for stage, zone, and the presence of plus disease. Integrating stage, zone, and the presence of plus disease according to clinical guidelines yields ROP severity such that an interpretable AI system was developed to provide the stage from the lesion type, the zone from the lesion location, and the presence of plus disease from a plus disease classification model. The ROP severity was calculated accordingly and compared with the assessment of a human expert. Our method achieved an area under the curve (AUC) of 0.95 (95% confidence interval [CI] 0.90–0.98) in assessing the severity level of ROP. Compared with clinical doctors, our method achieved the highest F1 score value of 0.76 in assessing the severity level of ROP. In conclusion, we developed an interpretable AI system for assessing the severity level of ROP that shows significant potential for use in clinical practice for ROP severity level screening.


  • Open Access

    AGSAM: Agent-Guided Segment Anything Model for Automatic Segmentation in Few-Shot Scenarios

    by Hao Zhou, Yao He, Xiaoxiao Cui, Zhi Xie

    Precise medical image segmentation of regions of interest (ROIs) is crucial for accurate disease diagnosis and progression assessment. However, acquiring high-quality annotated data at the pixel level poses a significant challenge due to the resource-intensive nature of this process. This scarcity of high-quality annotated data results in few-shot scenarios, which are highly prevalent in clinical applications. To address this obstacle, this paper introduces Agent-Guided SAM (AGSAM), an innovative approach that transforms the Segment Anything Model (SAM) into a fully automated segmentation method by automating prompt generation. Capitalizing on the pre-trained feature extraction and decoding capabilities of SAM-Med2D, AGSAM circumvents the need for manual prompt engineering, ensuring adaptability across diverse segmentation methods. Furthermore, the proposed feature augmentation convolution module (FACM) enhances model accuracy by promoting stable feature representations. Experimental evaluations demonstrate AGSAM’s consistent superiority over other methods across various metrics. These findings highlight AGSAM’s efficacy in tackling the challenges associated with limited annotated data while achieving high-quality medical image segmentation.