FKFred Kaggwa

Fred Kaggwa

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Fred Kaggwa has a total of 74 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Preserving clinical competence alongside AI in resource-constrained settings of the Americas

    by Milit S. Patel, Sruthi Ranganathan, Hector Acevedo, Gift Osei Agyemang, Edward Christopher Dee, Erin Jay G. Feliciano, Fred Kaggwa, Nancy Y. Lee, Fabio Y. Moraes, Felipe Ocampo Osorio, et al.

  • Open Access

    Evaluating the Generalisability of Convolutional Neural Networks for Diabetic Retinopathy Detection in Latin America and Sub-Saharan Africa

    by Rogers Mwavu, Fred Kaggwa, Simon Arunga, William Wasswa

    Diabetic retinopathy is a leading cause of vision loss worldwide, particularly impacting individuals in low- and middle-income countries with limited healthcare access. Early detection through automated screening systems is essential for improving outcomes, as timely intervention can prevent severe vision impairment. However, most of the available AI models have not been evaluated in low-resource settings. Hence, this study presents an evaluation of the efficacy of advanced deep learning architectures for detecting rDR across diverse population datasets. A dual-phase validation approach was employed to assess model performance. Internal validation utilised the BrSET dataset to establish baseline performance metrics, while external validation was conducted on the MoDRIA dataset, which encompasses various conditions and demographics, to evaluate model robustness. Key performance metrics, including accuracy, specificity, sensitivity, F1-score, and calibration scores, were systematically recorded and analysed. Internal validation revealed high accuracy across all models, EfficientNetB0 achieved the highest classification accuracy (0.9561; 95% CI 0.9490–0.9630), EfficientNetB3 demonstrated superior overall discriminative performance, achieving the highest AUROC (0.9892; 95% CI 0.9841–0.9934) highest sensitivity (0.9573), and lowest Brier score (0.0168). Meanwhile, DenseNet exhibited the most balanced clinical screening performance, achieving the highest F1-score (0.7259; 95% CI 0.6797–0.7669) and Youden Index (0.2381), indicating improved balance between sensitivity and specificity. In contrast, external validation revealed substantial deterioration in model performance across all architectures, highlighting major limitations in cross-population generalisability. Although EfficientNetB0 achieved the highest external accuracy (0.8821; 95% CI 0.8746–0.8898), AUROC values declined markedly across models (0.5140–0.6104), accompanied by poor sensitivity, reduced F1-scores, and substantial calibration instability. EfficientNetB3 achieved the highest external sensitivity (0.5939), whereas calibration analyses demonstrated unreliable probability estimation under domain-shift conditions. These findings suggest that AI models trained on geographically homogeneous retinal imaging datasets may not generalise reliably across underrepresented populations. Population differences and imaging variability substantially affected external model performance, highlighting the need for diverse datasets, rigorous external validation, and adaptive recalibration before clinical deployment of AI-driven DR screening systems.


  • Open Access

    Dialogues of delivery: a multilingual question-answer dataset for maternal healthcare in East African languages

    by Richard Kimera, Rogers Kuyeso, Emmanuel Maleka, Fortunate Tukamushaba, Wasswa William, Rogers Mwavu, David Sabiiti Bamutura, Joseph Ngonzi, Brenda Ainomugisha, Alexer Namuli, et al.

    There is a critical scarcity of domain-specific, clinically grounded Natural Language Processing (NLP) resources for African languages. In Western Uganda, linguistic diversity creates a barrier to maternal healthcare, as mothers lack access to health information in their native languages. The objective of this dataset is to provide a high-quality, in-language medical corpus to enable the development and fine-tuning of Large Language Models (LLMs) and conversational AI tools for maternal health in resource-constrained settings. The "Dialogues of Delivery" dataset is a multilingual, parallel corpus comprising 3,694 question-and-answer pairs presented in four languages: English, Luganda, Runyankore, and Swahili (14,800 total entries). Using facility-based convenience sampling at two health facilities in Western Uganda, primary data was collected via structured, open-ended questionnaires from 150 participants (expectant/postpartum mothers and maternal healthcare providers). The dataset underwent a rigorous forward-backward translation protocol by certified linguists and human-in-the-loop clinical validation by independent medical professionals. The dataset captures core maternal health domains, providing a culturally and clinically validated foundation for Afrocentric AI development.

  • Open Access

    A Weighted Ensemble Learning Approach with Synthetic Oversampling for Maize Yield Modeling in Data-limited Agro-ecological Zones of Uganda

    by Danison Taremwa, Emmanuel Ahishakiye, Aggrey Obbo, Paul Kisozi, Fred Kaggwa

    Sparse and irregular agricultural records constrain reliable crop yield modelling in many Sub-Saharan African regions. This study evaluates the use of ensemble machine learning combined with synthetic oversampling for maize yield modelling in data-limited agro-ecological zones of Uganda. Seasonal climatic variables, including rainfall, soil moisture, temperature, and solar radiation, were aggregated from satellite-derived datasets and integrated with maize-yield records from the Uganda Bureau of Statistics for 2018–2020. To address severe data imbalance and scarcity, the Synthetic Minority Oversampling Technique for Regression with Gaussian Noise (SMOGN) was employed to enhance representation of low- and high-yield conditions. An ensemble model combining LightGBM, Random Forest, and Decision Tree algorithms was developed and compared with individual machine-learning and deep-learning models. The ensemble achieved a coefficient of determination of approximately 0.99 and a root-mean-square error of approximately 0.06 t/ha, outperforming individual tree-based models and deep learning baselines (R² ≈ 0.79–0.83). Feature importance analysis indicated that soil moisture, rainfall, and solar radiation were the dominant climatic drivers of yield variability across zones. However, because a substantial proportion of the training samples were synthetically generated and the observations span only three years, the model should be interpreted as a methodological demonstration rather than as an operational yield-forecasting system. The findings indicate that combining ensemble learning with controlled synthetic data augmentation can support agricultural modelling in environments where long-term yield measurements are scarce. The proposed approach provides a foundation for future work incorporating extended field observations and independent validation datasets.


  • Describing the Performance and the Infrastructure Requirements of the Existing Artificial Intelligence (AI)-Based Diabetic Retinopathy (DR) Screening Algorithms for Diabetic Patients: an Umbrella Review

    by Rachel Kabunga, Justus Asasira, Sheilah Njuki, Atwine Daniel, Katharine Morley, Michael Morley, Fred Kaggwa, Justin C. Cikomola, Arunga Simon

    AI-based diabetic retinopathy (DR) screening algorithms have been evaluated in many countries and have shown promise in expanding access to screening, especially in low- and middle-income countries (LMICs). However, the literature lacks guidance on which algorithms are best suited for these settings. This umbrella review summarizes current evidence on the performance, infrastructure needs, and global implementation of AI-based DR screening tools. Following the Preferred Reporting Items for Systematic Review (PRISMA) guidelines, systematic reviews were identified through searches in PubMed, Embase, ScienceDirect, Scopus, and Google Scholar up to April 18, 2024. Eligible studies were reviewed, and findings were presented in tables and graphics. Twenty systematic reviews were included. Most algorithms were developed, validated, and used in high-income countries, with none developed or implemented in Africa. More than 400 algorithms were identified, of which 161 had some form of clinical validation, and 31 were validated in real-world settings. Sensitivity ranged from 66.0% to 100.0%, specificity from 59.5% to 98.7%, and AUROC from 87.8% to 99.1%. Only 12 algorithms have received regulatory approval, and 11 of them are currently used in clinical practice. AI-based DR screening models hold promise as diagnostic tools across diverse clinical settings, particularly where ophthalmic resources are limited. However, successful implementation depends on appropriate infrastructure, local validation, and regulatory support. Addressing the significant gaps in algorithm development and validation in Africa is essential to ensure equitable access and effective use of AI in DR screening.


  • Open Access

    Enablers and challenges of integrating digital health into medical education curricula: a scoping review

    by Wilson Tumuhimbise, Stefanie Theuring, Esther C. Atukunda, Mugyenyi R. Godfrey, Doreen Babirye, Fred Kaggwa, Mwavu Rogers, Kizza Gerald, Rebecca Nuwematsiko, Irene Wanyana, et al.


  • Open Access

    Review of machine learning applications for predicting the quality of biomass briquettes for sustainable and low-carbon energy solutions

    by Constance Nakato Nakimuli, Fred Kaggwa, Johan De Greef, David Kilama Okot, Julien Blondeau, Simon Kawuma


  • Open Access

    Assessment of Clinical Metadata on the Accuracy of Retinal Fundus Image Labels in Diabetic Retinopathy in Uganda: Case-Crossover Study Using the Multimodal Database of Retinal Images in Africa

    by Simon Arunga, Katharine Elise Morley, Teddy Kwaga, Michael Gerard Morley, Luis Filipe Nakayama, Rogers Mwavu, Fred Kaggwa, Julius Ssempiira, Leo Anthony Celi, Jessica E Haberer, et al.

    Background: Labeling color fundus photos (CFP) is an important step in the development of artificial intelligence screening algorithms for the detection of diabetic retinopathy (DR). Most studies use the International Classification of Diabetic Retinopathy (ICDR) to assign labels to CFP, plus the presence or absence of macular edema (ME). Images can be grouped as referrable or nonreferrable according to these classifications. There is little guidance in the literature about how to collect and use metadata as a part of the CFP labeling process. Objective: This study aimed to improve the quality of the Multimodal Database of Retinal Images in Africa (MoDRIA) by determining whether the availability of metadata during the image labeling process influences the accuracy, sensitivity, and specificity of image labels. MoDRIA was developed as one of the inaugural research projects of the Mbarara University Data Science Research Hub, part of the Data Science for Health Discovery and Innovation in Africa (DS-I Africa) initiative. Methods: This is a crossover assessment with 2 groups and 2 phases. Each group had 10 randomly assigned labelers who provided an ICDR score and the presence or absence of ME for each of the 50 CFP in a test image with and without metadata including blood pressure, visual acuity, glucose, and medical history. Specificity and sensitivity of referable retinopathy were based on ICDR scores, and ME was calculated using a 2-sided t test. Comparison of sensitivity and specificity for ICDR scores and ME with and without metadata for each participant was calculated using the Wilcoxon signed rank test. Statistical significance was set at P<.05. Results: The sensitivity for identifying referrable DR with metadata was 92.8% (95% CI 87.6-98.0) compared with 93.3% (95% CI 87.6-98.9) without metadata, and the specificity was 84.9% (95% CI 75.1-94.6) with metadata compared with 88.2% (95% CI 79.5-96.8) without metadata. The sensitivity for identifying the presence of ME was 64.3% (95% CI 57.6-71.0) with metadata, compared with 63.1% (95% CI 53.4-73.0) without metadata, and the specificity was 86.5% (95% CI 81.4-91.5) with metadata compared with 87.7% (95% CI 83.9-91.5) without metadata. The sensitivity and specificity of the ICDR score and the presence or absence of ME were calculated for each labeler with and without metadata. No findings were statistically significant. Conclusions: The sensitivity and specificity scores for the detection of referrable DR were slightly better without metadata, but the difference was not statistically significant. We cannot make definitive conclusions about the impact of metadata on the sensitivity and specificity of image labels in our study. Given the importance of metadata in clinical situations, we believe that metadata may benefit labeling quality. A more rigorous study to determine the sensitivity and specificity of CFP labels with and without metadata is recommended.


  • Open Access

    Enhancing the Implementation and Integration of mHealth Interventions in Resource-Limited Settings: A Scoping Review

    by Wilson Tumuhimbise, Stefanie Theuring, Fred Kaggwa, Esther C Atukunda, John Rubaihayo, Daniel Atwine, Juliet N Sekandi, Angella Musiimenta

    Background. Although mobile health (mHealth) interventions have shown promise in improving health outcomes, most of them rarely translate to scale. Prevailing mHealth studies are largely small-sized, short-term and donor-funded pilot studies with limited evidence on their effectiveness. To facilitate scale-up, several frameworks have been proposed to enhance the generic implementation of health interventions. However, there is a lack of a specific focus on the implementation and integration of mHealth interventions in routine care in low-resource settings. Our scoping review aimed to synthesize and develop a framework that could guide the implementation and integration of mHealth interventions.Methods:We searchedthePubMed, Google Scholar, and ScienceDirect databases for published theories, models, and frameworks related to the implementation and integration of clinical interventions from 1stJanuary 2000 to 31stDecember 2023. The data processing was guided by a scoping review methodology proposed by Arksey and O’Malley. Studies were included if they were i) peer-reviewed and published between 2000 and 2023, ii) explicitly described a framework for clinical intervention implementation and integration, or iii) available in full text and published in English. We integrated different domains and constructs from the reviewed frameworks to develop a new framework for implementing and integrating mHealth interventions.Results:We identified eight eligible papers with eight frameworks composed of 102 implementation domains. None of the identified frameworks were specific to the integration of mHealth interventions in low-resource settings. Two constructs (skill impartation and intervention awareness) related to the training domain, four constructs (technical and logistical support, identifying committed staff, supervision, and redesigning) from the restructuring domain, two constructs (monetary incentives and nonmonetary incentives) from the incentivize domain, two constructs (organizational mandates and government mandates) from the mandate domain and two constructs (collaboration and routine workflows) from the integrate domain. Therefore, a new framework that outlines five main domains—train, restructure, incentivize, mandate, and integrate (TRIMI)—in relation to the integration and implementation of mHealth interventions in low-resource settings emerged.Conclusion:The TRIMI framework presents a realistic and realizable solution for the implementation and integration deficits of mHealth interventions in low-resource settings.

  • Open Access

    Assessment of Clinical Metadata on the Accuracy of Retinal Fundus Image Labels in Diabetic Retinopathy in Uganda: Case-Crossover Study Using the Multimodal Database of Retinal Images in Africa (Preprint)

    by Simon Arunga, Katharine Elise Morley, Teddy Kwaga, Michael Gerard Morley, Luis Filipe Nakayama, Rogers Mwavu, Fred Kaggwa, Julius Ssempiira, Leo Anthony Celi, Jessica E Haberer, et al.

    BACKGROUND Labeling color fundus photos (CFP) is an important step in the development of artificial intelligence screening algorithms for the detection of diabetic retinopathy (DR). Most studies use the International Classification of Diabetic Retinopathy (ICDR) to assign labels to CFP, plus the presence or absence of macular edema (ME). Images can be grouped as referrable or nonreferrable according to these classifications. There is little guidance in the literature about how to collect and use metadata as a part of the CFP labeling process. OBJECTIVE This study aimed to improve the quality of the Multimodal Database of Retinal Images in Africa (MoDRIA) by determining whether the availability of metadata during the image labeling process influences the accuracy, sensitivity, and specificity of image labels. MoDRIA was developed as one of the inaugural research projects of the Mbarara University Data Science Research Hub, part of the Data Science for Health Discovery and Innovation in Africa (DS-I Africa) initiative. METHODS This is a crossover assessment with 2 groups and 2 phases. Each group had 10 randomly assigned labelers who provided an ICDR score and the presence or absence of ME for each of the 50 CFP in a test image with and without metadata including blood pressure, visual acuity, glucose, and medical history. Specificity and sensitivity of referable retinopathy were based on ICDR scores, and ME was calculated using a 2-sided t test. Comparison of sensitivity and specificity for ICDR scores and ME with and without metadata for each participant was calculated using the Wilcoxon signed rank test. Statistical significance was set at P<.05. RESULTS The sensitivity for identifying referrable DR with metadata was 92.8% (95% CI 87.6-98.0) compared with 93.3% (95% CI 87.6-98.9) without metadata, and the specificity was 84.9% (95% CI 75.1-94.6) with metadata compared with 88.2% (95% CI 79.5-96.8) without metadata. The sensitivity for identifying the presence of ME was 64.3% (95% CI 57.6-71.0) with metadata, compared with 63.1% (95% CI 53.4-73.0) without metadata, and the specificity was 86.5% (95% CI 81.4-91.5) with metadata compared with 87.7% (95% CI 83.9-91.5) without metadata. The sensitivity and specificity of the ICDR score and the presence or absence of ME were calculated for each labeler with and without metadata. No findings were statistically significant. CONCLUSIONS The sensitivity and specificity scores for the detection of referrable DR were slightly better without metadata, but the difference was not statistically significant. We cannot make definitive conclusions about the impact of metadata on the sensitivity and specificity of image labels in our study. Given the importance of metadata in clinical situations, we believe that metadata may benefit labeling quality. A more rigorous study to determine the sensitivity and specificity of CFP labels with and without metadata is recommended.