Georges El Fakhri
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Georges El Fakhri has a total of 90 co-authors. Here are the top co-authors by number of shared publications:
- Thibault Marin
Yale School of Medicine
6 shared publications Elie Najem
Department of Imaging Dana‐Farber Cancer Institute Boston Massachusetts USA
3 shared publications- Fangxu Xing
Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
3 shared publications Jonghye Woo
Gordon Center for Medical Imaging, Department of Radiology Massachusetts General Hospital Boston Massachusetts USA
3 shared publicationsMaryam Moteabbed
Department of Radiation Oncology Massachusetts General Hospital Boston Massachusetts USA
3 shared publications- Arnaud Beddok
Department of Radiation Oncology, Institut Godinot, Reims, France; CRESTIC, Université de Reims Champagne-Ardenne, Reims, France
2 shared publications
Latest Publications
- Open Access
- 10 September 2026
- Published by Springer Nature in EJNMMI Radiopharmacy and Chemistry
- Vol. 11 (1) , 65
Optimization, automation and validation of NOP receptor PET radiopharmaceutical, [11C]NOP-1A for human use
In vivo human studies of the nociceptin/orphanin FQ peptide (NOP) receptor have been limited by the availability and reliable production of suitable PET ra
- 10 September 2026
- Published by Springer Nature in EJNMMI Radiopharmacy and Chemistry
- Vol. 11 (1) , 65
Open AccessOptimization, automation and validation of NOP receptor PET radiopharmaceutical, [11C]NOP-1A for human use
In vivo human studies of the nociceptin/orphanin FQ peptide (NOP) receptor have been limited by the availability and reliable production of suitable PET ra
- 1 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 10 (4) , 535-546
YRT-PET: An Open-Source GPU-Accelerated Image Reconstruction Engine for Positron Emission Tomography
Image reconstruction for positron emission tomography (PET) requires an accurate model of the PET scanner geometry and degrading factors to produce high-quality and clinically meaningful images. It is typically implemented by scanner manufacturers, with proprietary software designed specifically for each scanner. This limits the ability to perform direct comparisons between scanners or to develop advanced image reconstruction algorithms. Open-source image reconstruction software can offer an alternative to manufacturer implementations, allowing more control and portability. Several existing software packages offer a wide range of features and interfaces, but there is still a need for an engine that simultaneously offers reusable code, fast implementation and convenient interfaces for interoperability and extensibility.
- 1 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 10 (4) , 535-546
YRT-PET: An Open-Source GPU-Accelerated Image Reconstruction Engine for Positron Emission Tomography
Image reconstruction for positron emission tomography (PET) requires an accurate model of the PET scanner geometry and degrading factors to produce high-quality and clinically meaningful images. It is typically implemented by scanner manufacturers, with proprietary software designed specifically for each scanner. This limits the ability to perform direct comparisons between scanners or to develop advanced image reconstruction algorithms. Open-source image reconstruction software can offer an alternative to manufacturer implementations, allowing more control and portability. Several existing software packages offer a wide range of features and interfaces, but there is still a need for an engine that simultaneously offers reusable code, fast implementation and convenient interfaces for interoperability and extensibility.
- Open Access
- 26 July 2025
- Published by Springer Nature in EJNMMI Research
- Vol. 15 (1) , 1-9
In vivo 3D myocardial membrane potential mapping in humans using PET/MRI
Background: The mitochondrial membrane potential is a key biophysical parameter of mitochondrial function, which can be useful for the diagnosis and treatment monitoring of various cardiac diseases. We present a non-invasive PET/MR imaging method for 3D myocardial membrane potential mapping in humans. Results: An in vivo PET/MR imaging study was performed in three healthy subjects (1 male and 2 females; 48 ± 29 years old) under a study protocol approved by the local Institutional Review Board (IRB). Written informed consent was obtained from all subjects before participation in the study. The [18F](4-Fluorophenyl)triphenylphosphonium ([18F]-FTPP+) PET tracer was administered using a bolus-plus-infusion protocol (bolus activity of 301.2 ± 7.6 MBq, infusion activity of 90.0 ± 4.9 MBq), where an infusion of 120 min was started shortly after the bolus injection (time of infusion, TOI). Dynamic cardiac PET/MR imaging was performed approximately 20 min after the TOI and continued for 100 min. The extracellular volume fraction mapping was performed via cardiac MR with a free-breathing, 3D cardiac T 1 mapping sequence before and after the contrast agent injection (gadoterate meglumine, 0.1 mmol/kg). A linear tangent space alignment (LTSA) model-based method was used to reconstruct high-frame-rate dynamic images from sparsely sampled (k,t)-space data for T 1 . PET motion correction was performed using two steps of rigid image registration in a multi-resolution fashion, followed by a non-rigid image registration with B-spline transform. The tissue membrane potential was calculated using a kinetic model based on the Nernst equation with myocardial tracer concentration, tracer volume of distribution, and extracellular volume fraction measurements. Fully 3D membrane potential maps were successfully estimated from all three subjects. The estimated whole-heart membrane potentials were − 144.7 ± 3.5 mV, − 160.7 ± 5.3 mV, and − 165.8 ± 3.1 mV for each subject. Conclusion: The proposed method allows 3D myocardial membrane potential mapping in humans in vivo.
- 26 July 2025
- Published by Springer Nature in EJNMMI Research
- Vol. 15 (1) , 1-9
Open AccessIn vivo 3D myocardial membrane potential mapping in humans using PET/MRI
Background: The mitochondrial membrane potential is a key biophysical parameter of mitochondrial function, which can be useful for the diagnosis and treatment monitoring of various cardiac diseases. We present a non-invasive PET/MR imaging method for 3D myocardial membrane potential mapping in humans. Results: An in vivo PET/MR imaging study was performed in three healthy subjects (1 male and 2 females; 48 ± 29 years old) under a study protocol approved by the local Institutional Review Board (IRB). Written informed consent was obtained from all subjects before participation in the study. The [18F](4-Fluorophenyl)triphenylphosphonium ([18F]-FTPP+) PET tracer was administered using a bolus-plus-infusion protocol (bolus activity of 301.2 ± 7.6 MBq, infusion activity of 90.0 ± 4.9 MBq), where an infusion of 120 min was started shortly after the bolus injection (time of infusion, TOI). Dynamic cardiac PET/MR imaging was performed approximately 20 min after the TOI and continued for 100 min. The extracellular volume fraction mapping was performed via cardiac MR with a free-breathing, 3D cardiac T 1 mapping sequence before and after the contrast agent injection (gadoterate meglumine, 0.1 mmol/kg). A linear tangent space alignment (LTSA) model-based method was used to reconstruct high-frame-rate dynamic images from sparsely sampled (k,t)-space data for T 1 . PET motion correction was performed using two steps of rigid image registration in a multi-resolution fashion, followed by a non-rigid image registration with B-spline transform. The tissue membrane potential was calculated using a kinetic model based on the Nernst equation with myocardial tracer concentration, tracer volume of distribution, and extracellular volume fraction measurements. Fully 3D membrane potential maps were successfully estimated from all three subjects. The estimated whole-heart membrane potentials were − 144.7 ± 3.5 mV, − 160.7 ± 5.3 mV, and − 165.8 ± 3.1 mV for each subject. Conclusion: The proposed method allows 3D myocardial membrane potential mapping in humans in vivo.
- 3 May 2025
- Published by Wiley in Medical Physics
- Vol. 52 (7) , e17865
Modeling inter‐reader variability in clinical target volume delineation for soft tissue sarcomas using diffusion model
Background: Accurate delineation of the clinical target volume (CTV) is essential in the radiotherapy treatment of soft tissue sarcomas. However, this process is subject to inter‐reader variability due to the need for clinical assessment of risk and extent of potential microscopic spread. This can lead to inconsistencies in treatment planning, potentially impacting treatment outcomes. Most existing automatic CTV delineation methods do not account for this variability and can only generate a single CTV for each case. Purpose: This study aims to develop a deep learning‐based technique to generate multiple CTV contours for each case, simulating the inter‐reader variability in the clinical practice. Methods: We employed a publicly available dataset consisting of fluorodeoxyglucose positron emission tomography (FDG‐PET), x‐ray computed tomography (CT), and pre‐contrast T1‐weighted magnetic resonance imaging (MRI) scans from 51 patients with soft tissue sarcoma, along with an independent validation set containing five additional patients. An experienced reader drew a contour of the gross tumor volume (GTV) for each patient based on multi‐modality images. Subsequently, two additional readers, together with the first one, were responsible for contouring three CTVs in total based on the GTV. We developed a diffusion model‐based deep learning method that is capable of generating arbitrary number of different and plausible CTVs to mimic the inter‐reader variability in CTV delineation. The proposed model incorporates a separate encoder to extract features from the GTV masks, leveraging the critical role of GTV information in accurate CTV delineation. Results: The proposed diffusion model demonstrated superior performance with the highest Dice Index (0.902 compared to values below 0.881 for state‐of‐the‐art models) and the best generalized energy distance (GED) (0.209 compared to values exceeding 0.221 for state‐of‐the‐art models). It also achieved the second‐highest recall and precision metrics among the compared ambiguous image segmentation models. Results from both datasets exhibited consistent trends, reinforcing the reliability of our findings. Additionally, ablation studies exploring different model structures and input configurations highlighted the significance of incorporating prior GTV information for accurate CTV delineation. Conclusions: The proposed diffusion model successfully generates multiple plausible CTV contours for soft tissue sarcomas, effectively capturing inter‐reader variability in CTV delineation.
- 3 May 2025
- Published by Wiley in Medical Physics
- Vol. 52 (7) , e17865
Modeling inter‐reader variability in clinical target volume delineation for soft tissue sarcomas using diffusion model
Background: Accurate delineation of the clinical target volume (CTV) is essential in the radiotherapy treatment of soft tissue sarcomas. However, this process is subject to inter‐reader variability due to the need for clinical assessment of risk and extent of potential microscopic spread. This can lead to inconsistencies in treatment planning, potentially impacting treatment outcomes. Most existing automatic CTV delineation methods do not account for this variability and can only generate a single CTV for each case. Purpose: This study aims to develop a deep learning‐based technique to generate multiple CTV contours for each case, simulating the inter‐reader variability in the clinical practice. Methods: We employed a publicly available dataset consisting of fluorodeoxyglucose positron emission tomography (FDG‐PET), x‐ray computed tomography (CT), and pre‐contrast T1‐weighted magnetic resonance imaging (MRI) scans from 51 patients with soft tissue sarcoma, along with an independent validation set containing five additional patients. An experienced reader drew a contour of the gross tumor volume (GTV) for each patient based on multi‐modality images. Subsequently, two additional readers, together with the first one, were responsible for contouring three CTVs in total based on the GTV. We developed a diffusion model‐based deep learning method that is capable of generating arbitrary number of different and plausible CTVs to mimic the inter‐reader variability in CTV delineation. The proposed model incorporates a separate encoder to extract features from the GTV masks, leveraging the critical role of GTV information in accurate CTV delineation. Results: The proposed diffusion model demonstrated superior performance with the highest Dice Index (0.902 compared to values below 0.881 for state‐of‐the‐art models) and the best generalized energy distance (GED) (0.209 compared to values exceeding 0.221 for state‐of‐the‐art models). It also achieved the second‐highest recall and precision metrics among the compared ambiguous image segmentation models. Results from both datasets exhibited consistent trends, reinforcing the reliability of our findings. Additionally, ablation studies exploring different model structures and input configurations highlighted the significance of incorporating prior GTV information for accurate CTV delineation. Conclusions: The proposed diffusion model successfully generates multiple plausible CTV contours for soft tissue sarcomas, effectively capturing inter‐reader variability in CTV delineation.
- Open Access
- 23 February 2025
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 33, 100734
Gross tumor volume confidence maps prediction for soft tissue sarcomas from multi-modality medical images using a diffusion model
- 23 February 2025
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 33, 100734
Open AccessGross tumor volume confidence maps prediction for soft tissue sarcomas from multi-modality medical images using a diffusion model
- Open Access
PET mapping of receptor occupancy using joint direct parametric reconstruction
Receptor occupancy (RO) studies using PET neuroimaging play a critical role in the development of drugs targeting the central nervous system (CNS). The conventional approach to estimate drug receptor occupancy consists in estimation of binding potential changes between two PET scans (baseline and post-drug injection). This estimation is typically performed separately for each scan by first reconstructing dynamic PET scan data before fitting a kinetic model to time activity curves. This approach fails to properly model the noise in PET measurements, resulting in poor RO estimates, especially in low receptor density regions. Objective: In this work, we evaluate a novel joint direct parametric reconstruction framework to directly estimate distributions of RO and other kinetic parameters in the brain from a pair of baseline and post-drug injection dynamic PET scans. Methods: The proposed method combines the use of regularization on RO maps with alternating optimization to enable estimation of occupancy even in low binding regions. Results: Simulation results demonstrate the quantitative improvement of this method over conventional approaches in terms of accuracy and precision of occupancy. The proposed method is also evaluated in preclinical in-vivo experiments using 11C-MK-6884 and a muscarinic acetylcholine receptor 4 positive allosteric modulator drug, showing improved estimation of receptor occupancy as compared to traditional estimators. Conclusion: The proposed joint direct estimation framework improves RO estimation compared to conventional methods, especially in intermediate to low-binding regions. Significance: This work could potentially facilitate the evaluation of new drug candidates targeting the CNS.
Open AccessPET mapping of receptor occupancy using joint direct parametric reconstruction
Receptor occupancy (RO) studies using PET neuroimaging play a critical role in the development of drugs targeting the central nervous system (CNS). The conventional approach to estimate drug receptor occupancy consists in estimation of binding potential changes between two PET scans (baseline and post-drug injection). This estimation is typically performed separately for each scan by first reconstructing dynamic PET scan data before fitting a kinetic model to time activity curves. This approach fails to properly model the noise in PET measurements, resulting in poor RO estimates, especially in low receptor density regions. Objective: In this work, we evaluate a novel joint direct parametric reconstruction framework to directly estimate distributions of RO and other kinetic parameters in the brain from a pair of baseline and post-drug injection dynamic PET scans. Methods: The proposed method combines the use of regularization on RO maps with alternating optimization to enable estimation of occupancy even in low binding regions. Results: Simulation results demonstrate the quantitative improvement of this method over conventional approaches in terms of accuracy and precision of occupancy. The proposed method is also evaluated in preclinical in-vivo experiments using 11C-MK-6884 and a muscarinic acetylcholine receptor 4 positive allosteric modulator drug, showing improved estimation of receptor occupancy as compared to traditional estimators. Conclusion: The proposed joint direct estimation framework improves RO estimation compared to conventional methods, especially in intermediate to low-binding regions. Significance: This work could potentially facilitate the evaluation of new drug candidates targeting the CNS.
- Open Access
- 6 September 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (17) , 1976
Design Optimisation of a Flat-Panel, Limited-Angle TOF-PET Scanner: A Simulation Study
In time-of-flight positron emission tomography (TOF-PET), a coincidence time resolution (CTR) below 100 ps reduces the angular coverage requirements and, thus, the geometric constraints of the scanner design. Among other possibilities, this opens the possibility of using flat-panel PET detectors. Such a design would be more cost-accessible and compact and allow for a higher degree of modularity than a conventional ring scanner. However, achieving adequate CTR is a considerable challenge and requires improvements at every level of detection. Based on recent results in the ongoing development of optimised TOF-PET photodetectors and electronics, we expect that within a few years, a CTR of about 75 ps will be be achievable at the system level. In this work, flat-panel scanners with four panels and various design parameters were simulated, assessed and compared to a reference scanner based on the Siemens Biograph Vision using NEMA NU 2-2018 metrics. Point sources were also simulated, and a method for evaluating spatial resolution that is more appropriate for flat-panel geometry is presented. We also studied the effects of crystal readout strategies, comparing single-crystal and module readout levels. The results demonstrate that with a CTR below 100 ps, a flat-panel scanner can achieve image quality comparable to that of a reference clinical scanner, with considerable savings in scintillator material.
- 6 September 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (17) , 1976
Open AccessDesign Optimisation of a Flat-Panel, Limited-Angle TOF-PET Scanner: A Simulation Study
In time-of-flight positron emission tomography (TOF-PET), a coincidence time resolution (CTR) below 100 ps reduces the angular coverage requirements and, thus, the geometric constraints of the scanner design. Among other possibilities, this opens the possibility of using flat-panel PET detectors. Such a design would be more cost-accessible and compact and allow for a higher degree of modularity than a conventional ring scanner. However, achieving adequate CTR is a considerable challenge and requires improvements at every level of detection. Based on recent results in the ongoing development of optimised TOF-PET photodetectors and electronics, we expect that within a few years, a CTR of about 75 ps will be be achievable at the system level. In this work, flat-panel scanners with four panels and various design parameters were simulated, assessed and compared to a reference scanner based on the Siemens Biograph Vision using NEMA NU 2-2018 metrics. Point sources were also simulated, and a method for evaluating spatial resolution that is more appropriate for flat-panel geometry is presented. We also studied the effects of crystal readout strategies, comparing single-crystal and module readout levels. The results demonstrate that with a CTR below 100 ps, a flat-panel scanner can achieve image quality comparable to that of a reference clinical scanner, with considerable savings in scintillator material.
- Open Access
- 1 September 2024
- Published by Acoustical Society of America (ASA) in JASA Express Letters
- Vol. 4 (9)
Investigating muscle coordination patterns with Granger causality analysis in protrusive motion from tagged and diffusion MRI
The human tongue exhibits an orchestrated arrangement of internal muscles, working in sequential order to execute tongue movements. Understanding the muscle coordination patterns involved in tongue protrusive motion is crucial for advancing knowledge of tongue structure and function. To achieve this, this work focuses on five muscles known to contribute to protrusive motion. Tagged and diffusion MRI data are collected for analysis of muscle fiber geometry and motion patterns. Lagrangian strain measurements are derived, and Granger causal analysis is carried out to assess predictive information among the muscles. Experimental results suggest sequential muscle coordination of protrusive motion among distinct muscle groups.
- 1 September 2024
- Published by Acoustical Society of America (ASA) in JASA Express Letters
- Vol. 4 (9)
Open AccessInvestigating muscle coordination patterns with Granger causality analysis in protrusive motion from tagged and diffusion MRI
The human tongue exhibits an orchestrated arrangement of internal muscles, working in sequential order to execute tongue movements. Understanding the muscle coordination patterns involved in tongue protrusive motion is crucial for advancing knowledge of tongue structure and function. To achieve this, this work focuses on five muscles known to contribute to protrusive motion. Tagged and diffusion MRI data are collected for analysis of muscle fiber geometry and motion patterns. Lagrangian strain measurements are derived, and Granger causal analysis is carried out to assess predictive information among the muscles. Experimental results suggest sequential muscle coordination of protrusive motion among distinct muscle groups.
- 22 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 8 (8) , 950-958
Effects of List-Mode-Based Intraframe Motion Correction in Dynamic Brain PET Imaging
Motion is unavoidable in dynamic 18F-MK6240 Positron Emission Tomography (PET) imaging, especially in Alzheimer’s disease (AD) research requiring long scan duration. To understand how motion correction affects quantitative analysis, we investigated two approaches: II-MC, which corrects for both inter-frame and intra-frame motion, and IO-MC, which only corrects for inter-frame motion. These methods were applied to 83 scans from 34 subjects, and we calculated distribution volume ratios (DVR) using the multilinear reference tissue model with two parameters (MRTM2) in tau-rich brain regions. Most of the studies yielded similar DVR results for both II-MC and IO-MC. However, in one scan of an AD subject, the inferior temporal region showed 14% higher DVR with II-MC compared to IO-MC. This difference was reasonable given the AD diagnosis, although similar results were not observed in other regions. Although discrepancies between IO-MC and II-MC results were rare, they underscore the importance of incorporating intra-frame motion correction for more accurate and dependable PET quantitation, particularly in the context of dynamic imaging. These findings suggest that while the overall impact of intra-frame motion correction may be subtle, it can improve the reliability of longitudinal PET data, ultimately enhancing our understanding of tau protein distribution in AD pathology.
- 22 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 8 (8) , 950-958
Effects of List-Mode-Based Intraframe Motion Correction in Dynamic Brain PET Imaging
Motion is unavoidable in dynamic 18F-MK6240 Positron Emission Tomography (PET) imaging, especially in Alzheimer’s disease (AD) research requiring long scan duration. To understand how motion correction affects quantitative analysis, we investigated two approaches: II-MC, which corrects for both inter-frame and intra-frame motion, and IO-MC, which only corrects for inter-frame motion. These methods were applied to 83 scans from 34 subjects, and we calculated distribution volume ratios (DVR) using the multilinear reference tissue model with two parameters (MRTM2) in tau-rich brain regions. Most of the studies yielded similar DVR results for both II-MC and IO-MC. However, in one scan of an AD subject, the inferior temporal region showed 14% higher DVR with II-MC compared to IO-MC. This difference was reasonable given the AD diagnosis, although similar results were not observed in other regions. Although discrepancies between IO-MC and II-MC results were rare, they underscore the importance of incorporating intra-frame motion correction for more accurate and dependable PET quantitation, particularly in the context of dynamic imaging. These findings suggest that while the overall impact of intra-frame motion correction may be subtle, it can improve the reliability of longitudinal PET data, ultimately enhancing our understanding of tau protein distribution in AD pathology.
- 26 June 2024
- Published by American Chemical Society (ACS) in Journal of Medicinal Chemistry
- Vol. 67 (13) , 10517-10529
Advances and Insights in Positron Emission Tomography Tracers for Metabotropic Glutamate Receptor 4 Imaging
Positron emission tomography (PET) imaging employs positron-emitting radioisotopes to visualize biological processes in living subjects with high sensitivity and quantitative accuracy. As the most translational molecular imaging modality, PET can detect and image a wide range of radiotracers with minimal or no modification to parent drugs or targeting molecules. This Perspective provides a comprehensive analysis of developing PET radioligands using allosteric modulators for the metabotropic glutamate receptor subtype 4 (mGluR4) as a therapeutic target for neurological disorders. We focus on the selection of lead compounds from various chemotypes of mGluR4 positive allosteric modulators (PAMs) and discuss the challenges and systematic characterization required in developing brain-penetrant PET tracers specific for mGluR4. Through this analysis, we offer insights into the development and evaluation of PET ligands. Our review concludes that further research and development in this field hold great promise for discovering effective treatments for neurological disorders.
- 26 June 2024
- Published by American Chemical Society (ACS) in Journal of Medicinal Chemistry
- Vol. 67 (13) , 10517-10529
Advances and Insights in Positron Emission Tomography Tracers for Metabotropic Glutamate Receptor 4 Imaging
Positron emission tomography (PET) imaging employs positron-emitting radioisotopes to visualize biological processes in living subjects with high sensitivity and quantitative accuracy. As the most translational molecular imaging modality, PET can detect and image a wide range of radiotracers with minimal or no modification to parent drugs or targeting molecules. This Perspective provides a comprehensive analysis of developing PET radioligands using allosteric modulators for the metabotropic glutamate receptor subtype 4 (mGluR4) as a therapeutic target for neurological disorders. We focus on the selection of lead compounds from various chemotypes of mGluR4 positive allosteric modulators (PAMs) and discuss the challenges and systematic characterization required in developing brain-penetrant PET tracers specific for mGluR4. Through this analysis, we offer insights into the development and evaluation of PET ligands. Our review concludes that further research and development in this field hold great promise for discovering effective treatments for neurological disorders.