GLGuangpu Li

Guangpu Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Guangpu Li has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Research on Carbon Dioxide-Assisted Electrocoagulation Technology for Treatment of Divalent Cations in Water

    by Baoqi Chang, Guangpu Li, Fuqiang Guo, Shuang Lu, Yuhao Peng, Junwei Hou

    In the external drainage water of Xinjiang Karamay Petrochemical Company, the calcium and magnesium ion contents are as high as 630 mg/L and 1170 mg/L, respectively. These ions are subsequently scaled at large quantities in water treatment equipment, which greatly reduces the efficiency of the process. This study used a coupled chemical precipitation (CP) and electrocoagulation (EC) method to deal with external drainage water. The results show that the removal rates of calcium and magnesium were 94.71% and 96.33%, respectively, when the pH was adjusted with sodium silicate and EC was introduced after saturating the water samples with CO2. In this study, a quadratic polynomial equation was developed for predicting the removal of calcium and magnesium ions using this coupled technique under three factors of current density (CD) (15, 20 and 25 mA/cm2), reaction time (RT) (30, 40 and 50 min) and pH (10.0, 10.5 and 11.0). It was found that these three variables have a significant effect on the removal of both the abovementioned ions. The response surface method based on a Box–Behnken design showed that the average removal rates of calcium and magnesium ions could be 96.57% and 98.66% at a CD of 22 mA/cm2, RT of 46 min and pH of 11. This study confirmed the presence of calcium carbonate in the solid product through XRD and SEM analysis. The results indicate that this study is promising, and the developed technique can also be used to remove the high concentrations of calcium and magnesium ions from different wastewaters.


  • Open Access

    Phosphate Removal Efficiency and Life Cycle Assessment of Different Anode Materials in Electrocoagulation Treatment of Wastewater

    by Guangpu Li, Bin Zheng, Wenqing Zhang, Qiaona Liu, Mingzheng Li, Haibing Zhang

    The excessive discharge of phosphorus-containing wastewater contributes to eutrophication, posing a serious threat to aquatic ecosystems. Therefore, methods such as electrocoagulation should be utilized to remove phosphorus from wastewater prior to discharging it into a water body. In this study, we aimed to determine the effectiveness of electrocoagulation in treating simulated phosphorus-containing wastewater under different parameters, including anode material (aluminum, iron, and magnesium), electrode distance (ED) (1, 2.5, and 4.5 cm), pH (3, 6, and 9), and current density (CD) (3, 6, and 9 mA/cm2). Additionally, three models of phosphate removal, the pseudo-first-order (PFO), pseudo-second-order (PSO), and Behnajady–Modirshahla–Ghanbery (BMG) models, were used to simulate the relationship between phosphate concentration and time in the electrocoagulation process using the three metals for phosphate removal. The experimental results showed that the aluminum system had the highest removal efficiency (90%) when energized for 20 min under a CD of 3 mA/cm2, followed by those of the iron (80%) and magnesium (35%) systems. Furthermore, a life cycle assessment (LCA) showed that the aluminum electrode system had a smaller environmental impact than the iron and magnesium electrode systems. Therefore, the aluminum electrode system is suitable for phosphorus removal from wastewater.