Haipei Bie
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Haipei Bie has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Jinzhao Tian
School of Architecture, Carnegie Mellon University, Pittsburgh, PA 15213, USA
2 shared publications - Tian Li
Architecture Program, College of Architecture, University of Nebraska–Lincoln, Lincoln, USA
2 shared publications - Vivian Loftness
School of Architecture, Carnegie Mellon University, Pittsburgh, PA 15213, USA
2 shared publications Bingtong Guo
1 shared publication- Brian Gilligan
General Services Administration, 1800 F St NW, Washington, DC, 20405, USA
1 shared publication David King
1 shared publication
Latest Publications
- Open Access
- 6 March 2026
- Published by Elsevier in Building and Environment
- Vol. 295
A scalable framework for impact analysis of faults on indoor CO2 in buildings
- 6 March 2026
- Published by Elsevier in Building and Environment
- Vol. 295
Open AccessA scalable framework for impact analysis of faults on indoor CO2 in buildings
- Open Access
- 30 January 2025
- Published by Elsevier in Energy and Buildings
- Vol. 331
A review of air-side economizers in human-centered commercial buildings: Control logic, energy savings, IAQ potential, faults, and performance enhancement
- 30 January 2025
- Published by Elsevier in Energy and Buildings
- Vol. 331
Open AccessA review of air-side economizers in human-centered commercial buildings: Control logic, energy savings, IAQ potential, faults, and performance enhancement
- Open Access
- 3 May 2024
- Published by MDPI AG in Machine Learning and Knowledge Extraction
- Vol. 6 (2) , 965-986
VOD: Vision-Based Building Energy Data Outlier Detection
Outlier detection plays a critical role in building operation optimization and data quality maintenance. However, existing methods often struggle with the complexity and variability of building energy data, leading to poorly generalized and explainable results. To address the gap, this study introduces a novel Vision-based Outlier Detection (VOD) approach, leveraging computer vision models to spot outliers in the building energy records. The models are trained to identify outliers by analyzing the load shapes in 2D time series plots derived from the energy data. The VOD approach is tested on four years of workday time-series electricity consumption data from 290 commercial buildings in the United States. Two distinct models are developed for different usage purposes, namely a classification model for broad-level outlier detection and an object detection model for the demands of precise pinpointing of outliers. The classification model is also interpreted via Grad-CAM to enhance its usage reliability. The classification model achieves an F1 score of 0.88, and the object detection model achieves an Average Precision (AP) of 0.84. VOD is a very efficient path to identifying energy consumption outliers in building operations, paving the way for the enhancement of building energy data quality, operation efficiency, and energy savings.
- 3 May 2024
- Published by MDPI AG in Machine Learning and Knowledge Extraction
- Vol. 6 (2) , 965-986
Open AccessVOD: Vision-Based Building Energy Data Outlier Detection
Outlier detection plays a critical role in building operation optimization and data quality maintenance. However, existing methods often struggle with the complexity and variability of building energy data, leading to poorly generalized and explainable results. To address the gap, this study introduces a novel Vision-based Outlier Detection (VOD) approach, leveraging computer vision models to spot outliers in the building energy records. The models are trained to identify outliers by analyzing the load shapes in 2D time series plots derived from the energy data. The VOD approach is tested on four years of workday time-series electricity consumption data from 290 commercial buildings in the United States. Two distinct models are developed for different usage purposes, namely a classification model for broad-level outlier detection and an object detection model for the demands of precise pinpointing of outliers. The classification model is also interpreted via Grad-CAM to enhance its usage reliability. The classification model achieves an F1 score of 0.88, and the object detection model achieves an Average Precision (AP) of 0.84. VOD is a very efficient path to identifying energy consumption outliers in building operations, paving the way for the enhancement of building energy data quality, operation efficiency, and energy savings.