USUpasana Singh

Upasana Singh

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Upasana Singh has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Portable RGB Color-Sensor Platform for On-Farm Prediction of Sheep Pregnancy and Litter Size

    by Prashanthi Kovur, Scott MacKay, Ameen Naqvi, James Cook, Claudia Torres-Calzada, Ashley Zubkowski, Abby Kropielnicki, Yanna Xiao, Upasana Singh, Bryant Casem, et al.

    Early detection of sheep pregnancy and litter size (PLS) is crucial for the efficient management of the flock. However, standard ultrasonography for these purposes is not cost-effective for flock testing and requires trained and experienced operators. We have developed a simple handheld, real-time RGB color-sensor system that can measure six PLS candidate biomarkers, namely L-carnitine, glucose, lactate, creatinine, urea, and pyruvate using six in-house colorimetric assays, and a companion tablet application to report sheep PLS results. A benchtop microplate reader was used to obtain the measurements of the six assays using spiked, pooled sheep serum to produce a set of assay-specific weighted “color numbers” which were then used to calibrate the portable sensor system. To facilitate pregnancy testing in sheep during the coldest months of Canadian winter, we have also developed a custom-made temperature-controlled heating chamber so that the colorimetric assays can be incubated at approximately 21 °C. Here, we report on outdoor, on-device calibration of two chemically distinct assays spanning the concentration ranges represented in the panel. Creatinine, measured using the non-enzymatic alkaline 3,5-dinitrobenzoic acid reaction, increased monotonically over a concentration range of 0–200 µM (linear fit, R2 = 0.9469). Urea, measured using the enzyme-coupled Berthelot reaction, increased rapidly up to about 10 mM before saturating (quadratic fit, R2 = 0.9864). Both assays produced repeatable and concentration-dependent color change under the variable outdoor winter conditions experienced on-farm and therefore, hold great promise for the on-farm colorimetric measurement of metabolites of interest for pregnancy and litter size in sheep.

  • Open Access

    A Portable Colorimetric Biosensor Platform for Urinary Colorectal Cancer Biomarker Testing in Low-Resource Settings

    by Prashanthi Kovur, Scott MacKay, Songtian Bai, James Cook, Claudia Torres-Calzada, Dipanjan Bhattacharyya, Upasana Singh, David S. Wishart

    Early detection of colorectal cancer (CRC) is challenging in low-resource settings because access to colonoscopy and centralized laboratory testing is limited. Urine-based metabolite biomarkers offer a non-invasive alternative for CRC triage, but translating a laboratory assay into a point-of-care (PoC) system requires standardized fluid handling, operator-independent timing, field-compatible reagents, and quantitative calibration. Here, we present a low-cost, semi-automated PoC platform integrating a validated, sequential, three-metabolite CRC-biomarker assay with robotic fluid handling, a motorized chromatographic module, an optical reader, Bluetooth electronics, and tablet-guided control. The platform measures urinary diacetylspermine and hippuric acid, with creatinine serving as a normalization reference, and reports absolute quantitative concentrations. Automated dilution, tube positioning, timed incubation, controlled column elution, and software-guided transfer reduce operator-dependent variation. Using pooled urine samples spiked at clinically relevant concentrations, the creatinine assay showed a strong quadratic response (0–50 mM, R2 = 0.998), as did the diacetylspermine assay (0–4 μM, R2 = 0.979), while the hippuric acid assay showed a linear response of R2 = 0.989. The RGB sensor tracked the concentration-dependent trend observed with a laboratory microplate reader (R2 = 0.968–0.999). Reagents reformulated as lyophilized or pre-weighed, vacuum-sealed kits withstood accelerated heat and humidity (45 °C/70% RH) testing and international shipping to the pilot site very well. At approximately USD 490 for the complete instrument (including tablet) and roughly USD 7.65 in consumables per screening test, the platform offers a practical, quantitative, and portable route for decentralized CRC screening.


  • Open Access

    Redox-Modified Nanostructured Electrochemical Surfaces for Continuous Glucose Monitoring in Complex Biological Fluids

    by Sajjad Janfaza, Nandhinee Radha Shanmugam, Pawan Jolly, Prashanthi Kovur, Upasana Singh, Scott Mackay, David Wishart, Donald E. Ingber

    Continuous glucose monitoring is valuable for people with diabetes but faces limitations due to enzyme–electrode interactions and biofouling from biological samples that reduce sensor sensitivity and the monitoring performance. We created an enzyme-based electrochemical system with a unique nanocomposite coating that incorporates the redox molecule, aminoferrocene (NH2-Fc). This coating enhances stability via electroactivity and reduces nonspecific binding, as demonstrated through cyclic voltammetry. Our approach enables real-time glucose detection via chronoamperometry with a calculated linear range of 0.5 to 20 mM and a 1 mM detection limit. Validated with plasma and saliva, this platform shows promise for robust metabolite detection in clinical and research contexts. This versatile platform can be applied to accurately monitor a wide range of metabolites in various biological matrices, improving patient outcomes.