Min Zhu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Min Zhu has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Fansheng Chen
Hangzhou Institute for Advanced Study, University of Chinese Academy of Sciences, Hangzhou 310024, China
5 shared publications - Zhuoyue Hu
State Key Laboratory of Infrared Physics, Shanghai Institute of Technical Physics, Chinese Academy of Sciences, Shanghai 200083, China
5 shared publications - Qiyao Wang
Key Laboratory of Intelligent Infrared Perception, Shanghai Institute of Technical Physics, Chinese Academy of Sciences, Shanghai, China
2 shared publications - Xue Zhao
Key Laboratory of Intelligent Infrared Perception, Shanghai Institute of Technical Physics, Chinese Academy of Sciences, Shanghai, China
2 shared publications - Ji Bian
Key Laboratory of Intelligent Infrared Perception, Shanghai Institute of Technical Physics, Chinese Academy of Sciences, Shanghai, China
1 shared publication - Jianing Yu
Hangzhou Institute for Advanced Study, University of Chinese Academy of Sciences, Hangzhou, CHINA
1 shared publication
Latest Publications
- 10 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Geoscience and Remote Sensing Letters
- Vol. 21 (1545598X) , 1-5
Detection and Long-Term Analysis of Anomalous Pixels Based on Scene and On-Orbit Radiometric Traceability
In the on-orbit images of the SDGSAT-1 TIS, there are image striping phenomena caused by the nonlinear-response of the detector and flickering effects caused by the detector’s jump response. Based on the characteristics of the SDGSAT-1 TIS, a detection method for anomalous pixels using time-domain gradients and nonlinearity is proposed. This method also includes adaptive threshold adjustment and on-orbit data detection based on scene images. The results show that in each band, the number of flickering pixels with a detection probability exceeding 95% is fewer than 7, and the relative positions of these flickering pixels in the images are fixed. Additionally, traceability analysis of the on-orbit radiometric data reveals that the noise deviation of flickering pixels is more than 10% greater compared to normal pixels. This indicates that the flickering behavior is not random and that these pixels are more prone to flickering than others. In each band, the number of nonlinear-response pixels with a detection probability exceeding 95% is fewer than 6. Additionally, a traceability analysis of on-orbit radiometric data shows that the response deviation of nonlinear-response pixels is more than 0.7% compared to normal pixels. This result indicates that the occurrence of nonlinear-response pixels on orbit is not random and provides a new approach for early detection of anomalous pixels based on on-orbit radiometric data.
- 10 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Geoscience and Remote Sensing Letters
- Vol. 21 (1545598X) , 1-5
Detection and Long-Term Analysis of Anomalous Pixels Based on Scene and On-Orbit Radiometric Traceability
In the on-orbit images of the SDGSAT-1 TIS, there are image striping phenomena caused by the nonlinear-response of the detector and flickering effects caused by the detector’s jump response. Based on the characteristics of the SDGSAT-1 TIS, a detection method for anomalous pixels using time-domain gradients and nonlinearity is proposed. This method also includes adaptive threshold adjustment and on-orbit data detection based on scene images. The results show that in each band, the number of flickering pixels with a detection probability exceeding 95% is fewer than 7, and the relative positions of these flickering pixels in the images are fixed. Additionally, traceability analysis of the on-orbit radiometric data reveals that the noise deviation of flickering pixels is more than 10% greater compared to normal pixels. This indicates that the flickering behavior is not random and that these pixels are more prone to flickering than others. In each band, the number of nonlinear-response pixels with a detection probability exceeding 95% is fewer than 6. Additionally, a traceability analysis of on-orbit radiometric data shows that the response deviation of nonlinear-response pixels is more than 0.7% compared to normal pixels. This result indicates that the occurrence of nonlinear-response pixels on orbit is not random and provides a new approach for early detection of anomalous pixels based on on-orbit radiometric data.
- Open Access
- 13 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing
- Vol. 17 (19391404) , 6224-6232
First Assessment of SDGSAT-1 TIS Thermal Infrared Bands Calibration Using Landsat 9 TIRS-2
SDGSAT-1, the inaugural Earth science satellite commissioned by the Chinese Academy of Sciences, successfully lifted off from China's Taiyuan Satellite Launch Center on 5 November 2021. Cross calibration has emerged as an indispensable methodology, providing an effective means for quality assessment, stability monitoring, and uncertainty analysis. This is achieved through the meticulous selection of an appropriate reference instrument. In our investigation, we conducted a comprehensive evaluation of the absolute radiometric calibration accuracy of the thermal infrared spectrometer (TIS), a pivotal component aboard SDGSAT-1. Our evaluation centered on a meticulous comparative analysis, where we juxtaposed the brightness temperature (BT) values recorded by TIS with the BT values derived from TIRS-2, computed following the spectral alignment with TIS. Our findings reveal that the current absolute BT bias for the B 2 channel of TIS is less than 0.52 K. Meanwhile, the B 3 channel exhibits a slightly larger fluctuation in absolute BT bias, yet remains within acceptable parameters, registering at less than 1 K. Notably, B 3 emerges as the more dependable option for accurately gauging the temperature of the target region. Specifically, when the BT of B 3 surpasses 290 K, the BT bias remains consistently below 0.3 K. In light of the approximately 40-min time difference in the water surface data utilized in our study, we conducted simulations to assess the channel BT of TIS under the scenario of a 0.25 °C water temperature variation. Our simulations conclusively demonstrate that the corresponding change in BT does not exceed 0.25 K.
- 13 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing
- Vol. 17 (19391404) , 6224-6232
Open AccessFirst Assessment of SDGSAT-1 TIS Thermal Infrared Bands Calibration Using Landsat 9 TIRS-2
SDGSAT-1, the inaugural Earth science satellite commissioned by the Chinese Academy of Sciences, successfully lifted off from China's Taiyuan Satellite Launch Center on 5 November 2021. Cross calibration has emerged as an indispensable methodology, providing an effective means for quality assessment, stability monitoring, and uncertainty analysis. This is achieved through the meticulous selection of an appropriate reference instrument. In our investigation, we conducted a comprehensive evaluation of the absolute radiometric calibration accuracy of the thermal infrared spectrometer (TIS), a pivotal component aboard SDGSAT-1. Our evaluation centered on a meticulous comparative analysis, where we juxtaposed the brightness temperature (BT) values recorded by TIS with the BT values derived from TIRS-2, computed following the spectral alignment with TIS. Our findings reveal that the current absolute BT bias for the B 2 channel of TIS is less than 0.52 K. Meanwhile, the B 3 channel exhibits a slightly larger fluctuation in absolute BT bias, yet remains within acceptable parameters, registering at less than 1 K. Notably, B 3 emerges as the more dependable option for accurately gauging the temperature of the target region. Specifically, when the BT of B 3 surpasses 290 K, the BT bias remains consistently below 0.3 K. In light of the approximately 40-min time difference in the water surface data utilized in our study, we conducted simulations to assess the channel BT of TIS under the scenario of a 0.25 °C water temperature variation. Our simulations conclusively demonstrate that the corresponding change in BT does not exceed 0.25 K.
- Open Access
- 2 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing
- Vol. 17 (19391404) , 6233-6240
Cross Calibration of SDGSAT-1/TIS Thermal Infrared Bands With FY-4A/AGRI
Launched in November 2021, the sustainable development science satellite-1 carries the thermal infrared spectrometer (TIS) as a pivotal payload. Achieving precise radiometric calibration for geophysical parameter accuracy is crucial. Leveraging the frequent cross-calibration capability of the geostationary satellite FY-4A/advanced geostationary radiation imager (AGRI), this study addresses observational geometry challenges. The proposed radiance correction model for FY-4A/AGRI effectively reduces radiance discrepancies caused by differences in satellite zenith angles between TIS and AGRI. After integrating the corrected data into nadir-observed statistics, the long-term brightness temperature (BT) bias of TIS and AGRI was monitored. The results show that the daytime and nighttime BT bias exhibit similar trends, with the B 2 band mainly showing negative bias. Overall, the BT bias for the B 2 and B 3 bands is within 1 K. The standard deviation of the BT bias for approximately 2250 sample points was calculated, revealing the values of 0.22 K and 0.40 K during the daytime, and 0.31 K and 0.57 K at night. The introduced model error remains below 0.31 K. Regarding the uncertainty of the BT bias introduced by spectral matching, when the spectral broadening is 1.15 times the wavelength interval, the uncertainty is less than 0.29 K for B 2 and less than 0.38 K for B 3. This work enhances our understanding of radiometric calibration challenges, providing insights into satellite-based geophysical parameter accuracy.
- 2 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing
- Vol. 17 (19391404) , 6233-6240
Open AccessCross Calibration of SDGSAT-1/TIS Thermal Infrared Bands With FY-4A/AGRI
Launched in November 2021, the sustainable development science satellite-1 carries the thermal infrared spectrometer (TIS) as a pivotal payload. Achieving precise radiometric calibration for geophysical parameter accuracy is crucial. Leveraging the frequent cross-calibration capability of the geostationary satellite FY-4A/advanced geostationary radiation imager (AGRI), this study addresses observational geometry challenges. The proposed radiance correction model for FY-4A/AGRI effectively reduces radiance discrepancies caused by differences in satellite zenith angles between TIS and AGRI. After integrating the corrected data into nadir-observed statistics, the long-term brightness temperature (BT) bias of TIS and AGRI was monitored. The results show that the daytime and nighttime BT bias exhibit similar trends, with the B 2 band mainly showing negative bias. Overall, the BT bias for the B 2 and B 3 bands is within 1 K. The standard deviation of the BT bias for approximately 2250 sample points was calculated, revealing the values of 0.22 K and 0.40 K during the daytime, and 0.31 K and 0.57 K at night. The introduced model error remains below 0.31 K. Regarding the uncertainty of the BT bias introduced by spectral matching, when the spectral broadening is 1.15 times the wavelength interval, the uncertainty is less than 0.29 K for B 2 and less than 0.38 K for B 3. This work enhances our understanding of radiometric calibration challenges, providing insights into satellite-based geophysical parameter accuracy.
- Open Access
- 11 September 2022
- Published by MDPI AG in Remote Sensing
- Vol. 14 (18) , 4543
SDGSAT-1 TIS Prelaunch Radiometric Calibration and Performance
SDGSAT-1 was launched in November 2021, and TIS (Thermal infrared sensor) is a major instrument onboard this satellite. An analysis of the radiometric calibration and noise performance of the TIS has been carried out in the thermal vacuum chamber before launch in order to ensure that it meets the requirements. The prelaunch test results show NEdT (noise equivalent temperature difference) is 0.034 K, 0.047 K and 0.076 K@300 K for the three bands, respectively. The maximum fitting residuals are less than 0.5 K at measured blackbody temperatures. In addition, this paper also discusses the dependence between TIS performance and instrument temperature and focal plane array (FPA) temperature. The good radiometric and noise performance of TIS demonstrates it has potential to provide high resolution thermal remote sensing data in urban heat island, and other environmental issues research.
- 11 September 2022
- Published by MDPI AG in Remote Sensing
- Vol. 14 (18) , 4543
Open AccessSDGSAT-1 TIS Prelaunch Radiometric Calibration and Performance
SDGSAT-1 was launched in November 2021, and TIS (Thermal infrared sensor) is a major instrument onboard this satellite. An analysis of the radiometric calibration and noise performance of the TIS has been carried out in the thermal vacuum chamber before launch in order to ensure that it meets the requirements. The prelaunch test results show NEdT (noise equivalent temperature difference) is 0.034 K, 0.047 K and 0.076 K@300 K for the three bands, respectively. The maximum fitting residuals are less than 0.5 K at measured blackbody temperatures. In addition, this paper also discusses the dependence between TIS performance and instrument temperature and focal plane array (FPA) temperature. The good radiometric and noise performance of TIS demonstrates it has potential to provide high resolution thermal remote sensing data in urban heat island, and other environmental issues research.
- Open Access
Improved Intra-Pixel Sensitivity Characterization Based on Diffusion and Coupling Model for Infrared Focal Plane Array Photodetector
The high-precision characterization of the intra-pixel sensitivity (IPS) for infrared focal plane array (FPA) photodetector is of great significance to high-precision photometry and astrometry in astronomy, as well as target tracking in under-sampled remote sensing images. The discrete sub-pixel response (DSPR) model and fill factor model have been used for IPS characterization in some studies. However, these models are incomplete and lack the description of physical process of charge diffusion and capacitance coupling, leading to the inaccuracy of IPS characterization. In this paper, we propose an improved IPS characterization method based on the diffusion and coupling physical (DCP) model for infrared FPA photodetector, which considering the processes of generation and collection of the charge, can improve the accuracy of IPS characterization. The IPS model can be obtained by convolving the ideal rectangular response function with the charge diffusion function and the capacitive coupling function. Then, the IPS model is convolved with the beam spot profile to obtain the beam spot scanning response model. Finally, we calculate the parameters of IPS by fitting the beam spot scanning response map with the proposed DCP model based on the Trust-Region-Reflective algorithm. Simulated results show that when using a 3 μm beam spot to scan, the error of IPS characterization based on DCP model is 0.63%, which is better than that of DSPR model’s 3.70%. Experimental results show that the fitting error of the beam spot scan response model based on DCP model is 4.29%, which is better than that of DSPR model’s 8.31%.
Open AccessImproved Intra-Pixel Sensitivity Characterization Based on Diffusion and Coupling Model for Infrared Focal Plane Array Photodetector
The high-precision characterization of the intra-pixel sensitivity (IPS) for infrared focal plane array (FPA) photodetector is of great significance to high-precision photometry and astrometry in astronomy, as well as target tracking in under-sampled remote sensing images. The discrete sub-pixel response (DSPR) model and fill factor model have been used for IPS characterization in some studies. However, these models are incomplete and lack the description of physical process of charge diffusion and capacitance coupling, leading to the inaccuracy of IPS characterization. In this paper, we propose an improved IPS characterization method based on the diffusion and coupling physical (DCP) model for infrared FPA photodetector, which considering the processes of generation and collection of the charge, can improve the accuracy of IPS characterization. The IPS model can be obtained by convolving the ideal rectangular response function with the charge diffusion function and the capacitive coupling function. Then, the IPS model is convolved with the beam spot profile to obtain the beam spot scanning response model. Finally, we calculate the parameters of IPS by fitting the beam spot scanning response map with the proposed DCP model based on the Trust-Region-Reflective algorithm. Simulated results show that when using a 3 μm beam spot to scan, the error of IPS characterization based on DCP model is 0.63%, which is better than that of DSPR model’s 3.70%. Experimental results show that the fitting error of the beam spot scan response model based on DCP model is 4.29%, which is better than that of DSPR model’s 8.31%.