Junko Hara
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Junko Hara has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Ryo Yamakuni
Department of Radiology and Nuclear Medicine, School of Medicine, Fukushima Medical University, 1 Hikariga-oka, Fukushima, 960-1295, Japan.
3 shared publications - Shiro Ishii
Department of Radiology, Fukushima Medical University, Fukushima, Japan
3 shared publications - Hirofumi Sekino
Department of Radiology and Nuclear Medicine, Fukushima Medical University, Fukushima, Japan
2 shared publications - Hiroshi Ito
Department of Radiology and Nuclear Medicine, Fukushima Medical University, Fukushima, Japan
2 shared publications - Kenji Fukushima
Department of Radiology and Nuclear Medicine, Fukushima Medical University, Fukushima, Japan
2 shared publications - Shigeyasu Sugawara
Advanced Clinical Research Center, Fukushima Medical University, Fukushima, Japan
2 shared publications
Latest Publications
- 4 December 2025
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 40 (3) , 357-363
Preoperative diagnostic accuracy of thyroid follicular carcinoma using fluorine-18-fluorodeoxyglucose-positron emission tomography/computed tomography and blood data
Objective To evaluate the diagnostic accuracy of fluorine-18-fluorodeoxyglucose-positron emission tomography (18F-FDG-PET), computed tomography (CT), thyroid markers, and their combination for diagnosing thyroid follicular carcinoma. Methods We analyzed 53 patients (12, 10, and 31 with follicular cancer, follicular adenoma, and adenomatous goiter, respectively) selected from 12,403 consecutive patients who underwent preoperative 18F-FDG-PET/CT at our hospital between January 2013 and December 2019. Blood data, including thyroxine, triiodothyronine, thyroid-stimulating hormone, and thyroglobulin levels, as well as the patients’ age, sex, thyroid tumor maximum standardized uptake value (SUVmax), and calcification, were compared between the follicular carcinoma and benign thyroid tumor (adenoma and adenomatous goiter) groups. Comparisons were performed using Student’s t-test, Mann–Whitney U test, or chi-squared test. For factors showing significant group differences, cut-off values were determined using receiver operating characteristic (ROC) analysis. Results Significant differences were observed between the two groups regarding calcification, SUVmax, SUVmax/tumor size, and thyroglobulin levels (all p < 0.01). Peripheral calcification was more common in follicular carcinomas (6/12 cases) than in benign thyroid tumors (1/41 cases). The area under the ROC curve (AUC) was 0.89 for SUVmax, with a Youden index cut-off value of 5.2, yielding 100% sensitivity and 73.2% specificity. For thyroglobulin, the AUC was 0.739, with a Youden index cut-off value of 3379, resulting in 58.3% sensitivity and 87.8% specificity. Only 2.4% of benign thyroid tumors were positive for all three indicators (SUVmax > 5.2, presence of tumor calcification, and thyroglobulin > 3379), whereas 50% of follicular carcinomas were positive for all indicators, corresponding to a sensitivity and specificity for malignancy of 50% and 97.6%, respectively. Notably, no case of follicular carcinoma presented with all three indicators negative or SUVmax < 5.2 (100% specificity). Conclusions The combination of high SUVmax, CT-detected calcification, and high thyroglobulin levels strongly suggests follicular carcinoma and may warrant resection.
- 4 December 2025
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 40 (3) , 357-363
Preoperative diagnostic accuracy of thyroid follicular carcinoma using fluorine-18-fluorodeoxyglucose-positron emission tomography/computed tomography and blood data
Objective To evaluate the diagnostic accuracy of fluorine-18-fluorodeoxyglucose-positron emission tomography (18F-FDG-PET), computed tomography (CT), thyroid markers, and their combination for diagnosing thyroid follicular carcinoma. Methods We analyzed 53 patients (12, 10, and 31 with follicular cancer, follicular adenoma, and adenomatous goiter, respectively) selected from 12,403 consecutive patients who underwent preoperative 18F-FDG-PET/CT at our hospital between January 2013 and December 2019. Blood data, including thyroxine, triiodothyronine, thyroid-stimulating hormone, and thyroglobulin levels, as well as the patients’ age, sex, thyroid tumor maximum standardized uptake value (SUVmax), and calcification, were compared between the follicular carcinoma and benign thyroid tumor (adenoma and adenomatous goiter) groups. Comparisons were performed using Student’s t-test, Mann–Whitney U test, or chi-squared test. For factors showing significant group differences, cut-off values were determined using receiver operating characteristic (ROC) analysis. Results Significant differences were observed between the two groups regarding calcification, SUVmax, SUVmax/tumor size, and thyroglobulin levels (all p < 0.01). Peripheral calcification was more common in follicular carcinomas (6/12 cases) than in benign thyroid tumors (1/41 cases). The area under the ROC curve (AUC) was 0.89 for SUVmax, with a Youden index cut-off value of 5.2, yielding 100% sensitivity and 73.2% specificity. For thyroglobulin, the AUC was 0.739, with a Youden index cut-off value of 3379, resulting in 58.3% sensitivity and 87.8% specificity. Only 2.4% of benign thyroid tumors were positive for all three indicators (SUVmax > 5.2, presence of tumor calcification, and thyroglobulin > 3379), whereas 50% of follicular carcinomas were positive for all indicators, corresponding to a sensitivity and specificity for malignancy of 50% and 97.6%, respectively. Notably, no case of follicular carcinoma presented with all three indicators negative or SUVmax < 5.2 (100% specificity). Conclusions The combination of high SUVmax, CT-detected calcification, and high thyroglobulin levels strongly suggests follicular carcinoma and may warrant resection.
- 11 May 2025
- Published by SAGE Publications in Acta Radiologica
- Vol. 66 (9) , 1018-1025
Detection of amyloid deposition in the hip and shoulder joints on CT scans as indicative of ATTR-type cardiac amyloidosis
Background: Amyloid deposition manifests as thickening and calcification of the joints on computed tomography (CT) images. Purpose: To investigate the diagnostic potential of thickening and calcification of the shoulder and hip joints for the detection of transthyretin amyloid cardiomyopathy (ATTR-CM). Material and Methods: We included 19 patients who had been assessed using 99m Tc-pyrophosphate scintigraphy between January 2019 and December 2022 and diagnosed with ATTR-CM. The incidence of calcification and synovial thickening in the hip and shoulder joints of the patients and controls was evaluated. Two radiologists determined differences in joint calcification and thickness on CT images using Pearson chi-square tests and unpaired t-tests, respectively. Results: Shoulder and hip joint thickness (both P < 0.01) and calcifications ( P < 0.05) significantly differed between the groups. The area under the receiver operating characteristic curve (AUC) was 0.74 for the shoulder joint, and the cut-off Youden index was 16.1 mm, with a sensitivity and specificity of 63.2% and 78.9%, respectively. The AUC was 0.844 for the hip joint, with an optimal cutoff of 11.8 mm, with a sensitivity and specificity of 71.4% and 89.5%, respectively. Inter-observer agreement was substantial between the radiologists for detecting hip and/or shoulder joint calcification (κ = 0.712). The interclass correlation coefficients (2, 1) were 0.65 and 0.71 for measurements of shoulder and hip joint thickness, respectively. Conclusion: Thickened and calcified shoulder and hip joints are more likely to be found in patients with clinically diagnosed ATTR-CM than those without.
- 11 May 2025
- Published by SAGE Publications in Acta Radiologica
- Vol. 66 (9) , 1018-1025
Detection of amyloid deposition in the hip and shoulder joints on CT scans as indicative of ATTR-type cardiac amyloidosis
Background: Amyloid deposition manifests as thickening and calcification of the joints on computed tomography (CT) images. Purpose: To investigate the diagnostic potential of thickening and calcification of the shoulder and hip joints for the detection of transthyretin amyloid cardiomyopathy (ATTR-CM). Material and Methods: We included 19 patients who had been assessed using 99m Tc-pyrophosphate scintigraphy between January 2019 and December 2022 and diagnosed with ATTR-CM. The incidence of calcification and synovial thickening in the hip and shoulder joints of the patients and controls was evaluated. Two radiologists determined differences in joint calcification and thickness on CT images using Pearson chi-square tests and unpaired t-tests, respectively. Results: Shoulder and hip joint thickness (both P < 0.01) and calcifications ( P < 0.05) significantly differed between the groups. The area under the receiver operating characteristic curve (AUC) was 0.74 for the shoulder joint, and the cut-off Youden index was 16.1 mm, with a sensitivity and specificity of 63.2% and 78.9%, respectively. The AUC was 0.844 for the hip joint, with an optimal cutoff of 11.8 mm, with a sensitivity and specificity of 71.4% and 89.5%, respectively. Inter-observer agreement was substantial between the radiologists for detecting hip and/or shoulder joint calcification (κ = 0.712). The interclass correlation coefficients (2, 1) were 0.65 and 0.71 for measurements of shoulder and hip joint thickness, respectively. Conclusion: Thickened and calcified shoulder and hip joints are more likely to be found in patients with clinically diagnosed ATTR-CM than those without.
- 2 May 2024
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 48 (6) , 882-888
Respiratory Displacement of the Right Adrenal Vein: Comparison of Inspiratory and Expiratory Computed Tomography With Catheter Venography
Objective: The aim of the study is to reveal the respiratory displacement of the right adrenal vein (RAV) to predict the exact location of the RAV during adrenal venous sampling (AVS). Methods: Computed tomography (CT) scans obtained 45 seconds (breath-hold at inhalation) and 70 seconds (breath-hold at exhalation) after contrast material injection were compared to venograms of the RAV of patients with primary aldosteronism who underwent AVS between January 2016 and December 2020. The craniocaudal distance between the center of the Th11/12 disc and the RAV orifice was measured; the craniocaudal location of the RAV orifice was also specified relative to vertebral bodies and intervertebral discs on inspiratory phase CT (In-CT), expiratory phase CT (Ex-CT), and catheter venography. The transverse and vertical angles of the RAV and the position of the RAV orifice on the inferior vena cava (IVC) circumference were measured on In-CT and Ex-CT. Results: In total, 51 patients (30 males, 21 females; mean age, 54.9 ± 11.1 years) were included. Craniocaudal distances between the center of the Th11/12 disc and RAV orifice were significantly different among the following 3 acquisitions: catheter venography versus In-CT (15.2 ± 8.4 mm); venography versus Ex-CT (5.6 ± 4.1 mm); and In-CT versus Ex-CT (19.6 ± 8.0 mm) (all, P < 0.001). The craniocaudal location of the RAV orifice on venography was significantly closer to that on Ex-CT than on In-CT (P < 0.001); measurements using venograms compared with In-CT and Ex-CT scans were within 1 level difference in 18 (35.3%) and 47 (92.2%) patients, respectively (P < 0.001). The vertical angle of the RAV was significantly more likely to be smaller on In-CT than on Ex-CT (P < 0.001). Conclusions: RAV locations and angles change with respiratory motion. It is crucial to consider the respiratory phase of CT because it can enable a more accurate prediction of the location of the RAV during AVS.
- 2 May 2024
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 48 (6) , 882-888
Respiratory Displacement of the Right Adrenal Vein: Comparison of Inspiratory and Expiratory Computed Tomography With Catheter Venography
Objective: The aim of the study is to reveal the respiratory displacement of the right adrenal vein (RAV) to predict the exact location of the RAV during adrenal venous sampling (AVS). Methods: Computed tomography (CT) scans obtained 45 seconds (breath-hold at inhalation) and 70 seconds (breath-hold at exhalation) after contrast material injection were compared to venograms of the RAV of patients with primary aldosteronism who underwent AVS between January 2016 and December 2020. The craniocaudal distance between the center of the Th11/12 disc and the RAV orifice was measured; the craniocaudal location of the RAV orifice was also specified relative to vertebral bodies and intervertebral discs on inspiratory phase CT (In-CT), expiratory phase CT (Ex-CT), and catheter venography. The transverse and vertical angles of the RAV and the position of the RAV orifice on the inferior vena cava (IVC) circumference were measured on In-CT and Ex-CT. Results: In total, 51 patients (30 males, 21 females; mean age, 54.9 ± 11.1 years) were included. Craniocaudal distances between the center of the Th11/12 disc and RAV orifice were significantly different among the following 3 acquisitions: catheter venography versus In-CT (15.2 ± 8.4 mm); venography versus Ex-CT (5.6 ± 4.1 mm); and In-CT versus Ex-CT (19.6 ± 8.0 mm) (all, P < 0.001). The craniocaudal location of the RAV orifice on venography was significantly closer to that on Ex-CT than on In-CT (P < 0.001); measurements using venograms compared with In-CT and Ex-CT scans were within 1 level difference in 18 (35.3%) and 47 (92.2%) patients, respectively (P < 0.001). The vertical angle of the RAV was significantly more likely to be smaller on In-CT than on Ex-CT (P < 0.001). Conclusions: RAV locations and angles change with respiratory motion. It is crucial to consider the respiratory phase of CT because it can enable a more accurate prediction of the location of the RAV during AVS.