Abdelrahman M. Anter
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Abdelrahman M. Anter has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Kamran M. Riaz
Dean McGee Eye Institute, University of Oklahoma
3 shared publications - Rahul Md Tonk
From the Bascom Palmer Eye Institute (S.S., A.M.A., S.L., R.S.T.), University of Miami, Miami, Florida, USA
3 shared publications - Sanjana Suraneni
From the Bascom Palmer Eye Institute (S.S., A.M.A., S.L., R.S.T.), University of Miami, Miami, Florida, USA
3 shared publications Adam R. Bleeker
Dean McGee Eye Institute (A.R.B., K.M.R.), University of OK, OK City, Oklahoma, USA
2 shared publicationsDavid A. Murphy
Dean McGee Eye Institute (A.R.B., K.M.R.), University of OK, OK City, Oklahoma, USA
2 shared publications- David L. Cooke
Affiliations Great Lakes Eye Care, Saint Joseph, Michigan, United States of America, Department of Neurology and Ophthalmology, Michigan State University, College of Osteopathic Medicine, East Lansing, Michigan, United States of America
2 shared publications
Latest Publications
- 9 September 2025
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 281, 118-125
Intraocular Lens Power Calculations in Posthyperopic Laser Vision Correction Eyes: Comparing Legacy and New No-History Formulas
- 9 September 2025
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 281, 118-125
Intraocular Lens Power Calculations in Posthyperopic Laser Vision Correction Eyes: Comparing Legacy and New No-History Formulas
- Open Access
- 1 October 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 50 (10) , 1026-1029
Updating the no-history method in intraocular lens power calculation after myopic laser vision correction
Purpose: To describe the Shammas-Cooke formula, an updated no-history (NH) formula for IOL calculation in eyes with prior myopic laser vision correction (M-LVC), and to compare the results with the Shammas PL, Haigis-L, and Barrett True-K NH formulas. Setting: Bascom Palmer Eye Institute (BPEI), The Lennar Foundation Medical Center, University of Miami, Miami, Florida; Dean A. McGee Eye Institute (DMEI), University of Oklahoma, Oklahoma City, Oklahoma; and private practice, Lynwood, California, and St Joseph, Michigan. Design: Retrospective observational study. Methods: We analyzed 2 large series of cataractous eyes with prior M-LVC. The training set (BPEI series of 330 eyes) was used to derive the new corneal power conversion equation to be used in the new Shammas-Cooke formula and the testing set (165 eyes of 165 patients in the DMEI series) to compare the updated formula with 3 other M-LVC NH formulas on the ASCRS calculator: Shammas PL, Haigis-L, and Barrett True-K NH. Results: Mean prediction error was 0.09 ± 0.56 diopters (D), −0.44 ± 0.61 D, −0.47 ± 0.59 D, and −0.18 ± 0.56 D and the mean absolute error was 0.43 D, 0.60 D, 0.61 D, and 0.45 D for the Shammas-Cooke, Shammas PL, Haigis-L, and Barrett True-K NH, respectively. The percentage of eyes within ±0.50 D was 66.7% vs 47.9%, 48.5%, and 65.5%, respectively. Conclusions: The Shammas-Cooke formula performed better than the Shammas PL and Haigis-L (P < .001 for both) and as well as the Barrett True-K NH formula (P = .923).
- 1 October 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 50 (10) , 1026-1029
Open AccessUpdating the no-history method in intraocular lens power calculation after myopic laser vision correction
Purpose: To describe the Shammas-Cooke formula, an updated no-history (NH) formula for IOL calculation in eyes with prior myopic laser vision correction (M-LVC), and to compare the results with the Shammas PL, Haigis-L, and Barrett True-K NH formulas. Setting: Bascom Palmer Eye Institute (BPEI), The Lennar Foundation Medical Center, University of Miami, Miami, Florida; Dean A. McGee Eye Institute (DMEI), University of Oklahoma, Oklahoma City, Oklahoma; and private practice, Lynwood, California, and St Joseph, Michigan. Design: Retrospective observational study. Methods: We analyzed 2 large series of cataractous eyes with prior M-LVC. The training set (BPEI series of 330 eyes) was used to derive the new corneal power conversion equation to be used in the new Shammas-Cooke formula and the testing set (165 eyes of 165 patients in the DMEI series) to compare the updated formula with 3 other M-LVC NH formulas on the ASCRS calculator: Shammas PL, Haigis-L, and Barrett True-K NH. Results: Mean prediction error was 0.09 ± 0.56 diopters (D), −0.44 ± 0.61 D, −0.47 ± 0.59 D, and −0.18 ± 0.56 D and the mean absolute error was 0.43 D, 0.60 D, 0.61 D, and 0.45 D for the Shammas-Cooke, Shammas PL, Haigis-L, and Barrett True-K NH, respectively. The percentage of eyes within ±0.50 D was 66.7% vs 47.9%, 48.5%, and 65.5%, respectively. Conclusions: The Shammas-Cooke formula performed better than the Shammas PL and Haigis-L (P < .001 for both) and as well as the Barrett True-K NH formula (P = .923).
- 20 March 2024
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 264, 44-52
Comparison of Legacy and New No-History IOL Power Calculation Formulas in Postmyopic Laser Vision Correction Eyes
- 20 March 2024
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 264, 44-52
Comparison of Legacy and New No-History IOL Power Calculation Formulas in Postmyopic Laser Vision Correction Eyes