Jiaying Fan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jiaying Fan has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
Jin Wang
2 shared publicationsKai Zhou
Department of Endocrinology, Ningbo Hospital of Traditional Chinese Medicine Affiliated to Zhejiang Chinese Medical University, Ningbo, China
2 shared publications
Latest Publications
- 29 August 2024
- Published by Springer Nature in Applied Biochemistry and Biotechnology
- Vol. 197 (1) , 534-544
Glucose Oxidase Coupling with Pistol-Like DNAzyme Based Colorimetric Assay for Sensitive Glucose Detection in Tears and Saliva
Non-invasive monitoring of glucose levels in tears and saliva is crucial for diagnosing and predicting various illnesses, such as diabetic nephropathy. However, the capability of the current glucose detection methods to identify small amounts of glucose with a high sensitivity remains a significant obstacle. This study proposes a simple, visual technique for sensitively detecting glucose levels from tears and saliva using glucose oxidase (GOx) to catalyze glucose and pistol-like DNAzyme (PLDz) to enhance the signal. In particular, the β-D-glucose present in the samples serves as the initial molecule that GOx identifies and catalyzes to generate gluconic acid and hydrogen peroxide (H2O2). The H2O2 induces the self-cleavage of PLDz, activating the “part b” sequence. This activation initiates catalytic hairpin assembly (CHA) and releases the DNAzyme section in the H1 probe. The DNAzyme acts as a peroxidase analog, facilitating the catalysis of the 3,3′,5,5′-tetramethylbenzidine (TMB)-hydrogen peroxide (H2O2) system and resulting in color changes. The proposed method exhibits a broad detection range of six orders of magnitude and a low limit of 0.32 μM for glucose detection. Furthermore, the proposed method was highly effective in detecting glucose in saliva and tears, suggesting that it could potentially diagnose hyperglycemia-related disorders in clinical environments.
- 29 August 2024
- Published by Springer Nature in Applied Biochemistry and Biotechnology
- Vol. 197 (1) , 534-544
Glucose Oxidase Coupling with Pistol-Like DNAzyme Based Colorimetric Assay for Sensitive Glucose Detection in Tears and Saliva
Non-invasive monitoring of glucose levels in tears and saliva is crucial for diagnosing and predicting various illnesses, such as diabetic nephropathy. However, the capability of the current glucose detection methods to identify small amounts of glucose with a high sensitivity remains a significant obstacle. This study proposes a simple, visual technique for sensitively detecting glucose levels from tears and saliva using glucose oxidase (GOx) to catalyze glucose and pistol-like DNAzyme (PLDz) to enhance the signal. In particular, the β-D-glucose present in the samples serves as the initial molecule that GOx identifies and catalyzes to generate gluconic acid and hydrogen peroxide (H2O2). The H2O2 induces the self-cleavage of PLDz, activating the “part b” sequence. This activation initiates catalytic hairpin assembly (CHA) and releases the DNAzyme section in the H1 probe. The DNAzyme acts as a peroxidase analog, facilitating the catalysis of the 3,3′,5,5′-tetramethylbenzidine (TMB)-hydrogen peroxide (H2O2) system and resulting in color changes. The proposed method exhibits a broad detection range of six orders of magnitude and a low limit of 0.32 μM for glucose detection. Furthermore, the proposed method was highly effective in detecting glucose in saliva and tears, suggesting that it could potentially diagnose hyperglycemia-related disorders in clinical environments.
- Open Access
- 3 May 2024
- Published by Springer Nature in Research Square
Glucose oxidase coupling with pistol-like DNAzyme based colorimetric assay for sensitive glucose detection in tears and saliva
Measuring glucose levels in tears and saliva is important for diagnosing and predicting several diseases without the need for intrusive procedures. Detecting low concentrations of glucose with high sensitivity is still a significant difficulty. A simple visual method was created to assess glucose levels in tears and saliva by utilizing glucose oxidase (GOx) to catalyze glucose and pistol-like DNAzyme (PLDz) for signal amplification. Specifically, the β-D-glucose in samples acts as the initial molecule that is identified and catalyzed by GOx to produce gluconic acid and H2O2. H2O2 triggered the self-cleavage of PLDz, resulting in the activation of the “part b” sequence to initiate catalytic hairpin assembly (CHA) and release the DNAzyme section in H1 probe. The DNAzyme functions as a peroxidase mimic, catalyzing the TMB–H2O2 system and leading to an increase in observable signals. The proposed approach demonstrated a low limit of detection of 0.32 µM and a broad detection range. Moreover, the proposed approach was effectively used to detect glucose in tears and saliva samples, indicating potential for diagnosing hyperglycemia-related disorders in clinical settings.
- 3 May 2024
- Published by Springer Nature in Research Square
Open AccessGlucose oxidase coupling with pistol-like DNAzyme based colorimetric assay for sensitive glucose detection in tears and saliva
Measuring glucose levels in tears and saliva is important for diagnosing and predicting several diseases without the need for intrusive procedures. Detecting low concentrations of glucose with high sensitivity is still a significant difficulty. A simple visual method was created to assess glucose levels in tears and saliva by utilizing glucose oxidase (GOx) to catalyze glucose and pistol-like DNAzyme (PLDz) for signal amplification. Specifically, the β-D-glucose in samples acts as the initial molecule that is identified and catalyzed by GOx to produce gluconic acid and H2O2. H2O2 triggered the self-cleavage of PLDz, resulting in the activation of the “part b” sequence to initiate catalytic hairpin assembly (CHA) and release the DNAzyme section in H1 probe. The DNAzyme functions as a peroxidase mimic, catalyzing the TMB–H2O2 system and leading to an increase in observable signals. The proposed approach demonstrated a low limit of detection of 0.32 µM and a broad detection range. Moreover, the proposed approach was effectively used to detect glucose in tears and saliva samples, indicating potential for diagnosing hyperglycemia-related disorders in clinical settings.