Liyang Mao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Liyang Mao has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Chenyao Tian
State Key Laboratory of Robotics and Systems, Harbin Institute of Technology, 2 Yikuang, Harbin 150080, China
3 shared publications - Hui Xie
State Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin 150001, China
3 shared publications - Xianghe Meng
Harbin Institute of Technology
3 shared publications - Hao Zhang
State Key Laboratory of Robotics and Systems, Harbin Institute of Technology, Harbin, China
2 shared publications Peng Yang
State Key Laboratory of Robotics and Systems, Harbin Institute of Technology, Harbin, China
2 shared publicationsXingjian Shen
State Key Laboratory of Robotics and Systems, Harbin Institute of Technology, Harbin, China
2 shared publications
Latest Publications
- 14 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 10 (4) , 3382-3389
A Dual-Circuit Magnetic Actuation System for Multi-Robot Collaboration in Large-Scale Medical Environments
Untethered miniature robots, after ultra-long-distance transportation to the lesion by continuum robots, can further deliver drugs to the deep fine tissues. Specifically, the magnetic steering continuum robot with the follower-the-leader manner enhances the safety of channel construction, while the magnetically-driven swimming robot with high mobility and maneuverability ensures robust, precise drug delivery. However, it requires an external actuation system capable of covering a large working space and generating diverse magnetic fields to support both robots. Here, a magnetic actuation system excited by dual circuits is developed for the linear combination of constant (up to 13.8 mT) and alternating magnetic fields (up to 93.2 Hz, 11.5 mT) within a large Ø308 mm spherical workspace. This is achieved through the resonance effect of series capacitors and suppressing induced currents through series choke coils. Minimizing conductive materials and optimizing the core and yoke structure reduce the impact of eddy current losses. Through effective temperature management and error compensation, the system can stably generate multiple required magnetic fields over extended periods, navigating the continuum robot through the aortic arch and delivering an untethered miniature swimming robot for precise exploration of the heart's microvasculature.
- 14 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 10 (4) , 3382-3389
A Dual-Circuit Magnetic Actuation System for Multi-Robot Collaboration in Large-Scale Medical Environments
Untethered miniature robots, after ultra-long-distance transportation to the lesion by continuum robots, can further deliver drugs to the deep fine tissues. Specifically, the magnetic steering continuum robot with the follower-the-leader manner enhances the safety of channel construction, while the magnetically-driven swimming robot with high mobility and maneuverability ensures robust, precise drug delivery. However, it requires an external actuation system capable of covering a large working space and generating diverse magnetic fields to support both robots. Here, a magnetic actuation system excited by dual circuits is developed for the linear combination of constant (up to 13.8 mT) and alternating magnetic fields (up to 93.2 Hz, 11.5 mT) within a large Ø308 mm spherical workspace. This is achieved through the resonance effect of series capacitors and suppressing induced currents through series choke coils. Minimizing conductive materials and optimizing the core and yoke structure reduce the impact of eddy current losses. Through effective temperature management and error compensation, the system can stably generate multiple required magnetic fields over extended periods, navigating the continuum robot through the aortic arch and delivering an untethered miniature swimming robot for precise exploration of the heart's microvasculature.
- Open Access
- 30 November 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-14
Programmable spatial magnetization stereolithographic printing of biomimetic soft machines with thin-walled structures
Soft machines respond to external magnetic stimuli with targeted shape changes and motions due to anisotropic magnetization, showing great potential in biomimetic applications. However, mimicking biological functionalities, particularly the complex hollow structures of organs and their dynamic behaviors, remains challenging. Here, we develop a printing method based on three-dimensional uniform magnetic field-assisted stereolithography to fabricate thin-walled soft machines with internal cavities and programmable magnetization. This printing technique employs Halbach arrays and an electromagnetic solenoid to generate an adjustable uniform magnetic field (up to 80 millitesla), efficiently orienting ferromagnetic particles, followed by solidification with patterned ultraviolet light. A support strategy and optimized material composition enhance printing stability and success rates. Our developed method enables fabrication of magnetic-driven soft machines capable of peristaltic propulsion, unidirectional fluid transport, periodic pumping action, and intake-expulsion deformation. These structures, achieving hollow ratios as high as 0.92 and enabling parallel manufacturing, highlight this technique’s considerable potential for biomedical applications by emulating complex biological behaviors and functions.
- 30 November 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-14
Open AccessProgrammable spatial magnetization stereolithographic printing of biomimetic soft machines with thin-walled structures
Soft machines respond to external magnetic stimuli with targeted shape changes and motions due to anisotropic magnetization, showing great potential in biomimetic applications. However, mimicking biological functionalities, particularly the complex hollow structures of organs and their dynamic behaviors, remains challenging. Here, we develop a printing method based on three-dimensional uniform magnetic field-assisted stereolithography to fabricate thin-walled soft machines with internal cavities and programmable magnetization. This printing technique employs Halbach arrays and an electromagnetic solenoid to generate an adjustable uniform magnetic field (up to 80 millitesla), efficiently orienting ferromagnetic particles, followed by solidification with patterned ultraviolet light. A support strategy and optimized material composition enhance printing stability and success rates. Our developed method enables fabrication of magnetic-driven soft machines capable of peristaltic propulsion, unidirectional fluid transport, periodic pumping action, and intake-expulsion deformation. These structures, achieving hollow ratios as high as 0.92 and enabling parallel manufacturing, highlight this technique’s considerable potential for biomedical applications by emulating complex biological behaviors and functions.
- Top Cited PapersOpen Access
- 4 May 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-16
Magnetic steering continuum robot for transluminal procedures with programmable shape and functionalities
Millimeter-scale soft continuum robots offer safety and adaptability in transluminal procedures due to their passive compliance, but this feature necessitates interactions with surrounding lumina, leading to potential medical risks and restricted mobility. Here, we introduce a millimeter-scale continuum robot, enabling apical extension while maintaining structural stability. Utilizing phase transition components, the robot executes cycles of tip-based elongation, steered accurately through programmable magnetic fields. Each motion cycle features a solid-like backbone for stability, and a liquid-like component for advancement, thereby enabling autonomous shaping without reliance on environmental interactions. Together with clinical imaging technologies, we demonstrate the capability of navigating through tortuous and fragile lumina to transport microsurgical tools. Once it reaches larger anatomical spaces such as stomach, it can morph into functional 3D structures that serve as surgical tools or sensing units, overcoming the constraints of initially narrow pathways. By leveraging this design paradigm, we anticipate enhanced safety, multi-functionality, and cooperative capabilities among millimeter-scale continuum robots, opening new avenues for transluminal robotic surgery.
- 4 May 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-16
Top Cited PapersOpen AccessMagnetic steering continuum robot for transluminal procedures with programmable shape and functionalities
Millimeter-scale soft continuum robots offer safety and adaptability in transluminal procedures due to their passive compliance, but this feature necessitates interactions with surrounding lumina, leading to potential medical risks and restricted mobility. Here, we introduce a millimeter-scale continuum robot, enabling apical extension while maintaining structural stability. Utilizing phase transition components, the robot executes cycles of tip-based elongation, steered accurately through programmable magnetic fields. Each motion cycle features a solid-like backbone for stability, and a liquid-like component for advancement, thereby enabling autonomous shaping without reliance on environmental interactions. Together with clinical imaging technologies, we demonstrate the capability of navigating through tortuous and fragile lumina to transport microsurgical tools. Once it reaches larger anatomical spaces such as stomach, it can morph into functional 3D structures that serve as surgical tools or sensing units, overcoming the constraints of initially narrow pathways. By leveraging this design paradigm, we anticipate enhanced safety, multi-functionality, and cooperative capabilities among millimeter-scale continuum robots, opening new avenues for transluminal robotic surgery.