Sarah M. Narehood
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Sarah M. Narehood has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Brian D. Cook
Department of Chemistry and Biochemistry, University of California, San Diego, La Jolla, CA 92093
4 shared publications - Mark A. Herzik
Department of Chemistry and Biochemistry, University of California, San Diego, La Jolla, CA 92093, USA
4 shared publications - Kelly L. McGuire
Department of Chemistry and Biochemistry, University of California
3 shared publications - F. Akif Tezcan
Department of Chemistry and Biochemistry, University of California, San Diego, La Jolla, CA 92093, USA
2 shared publications - Li Y
Department of Chemistry and Biochemistry, University of California San Diego, La Jolla, USA
2 shared publications - A. Eroğlu Tezcan1 shared publication
Latest Publications
- Open Access
A Surfactant Cocktail Overcomes Air-Water Interface Artifacts in Single-Particle CryoEM
Single-particle cryogenic electron microscopy (cryoEM) is a widely used technique for structure determination of biomacromolecules to near-atomic resolution. Random distributions of these molecules in vitrified ice are necessary to accumulate enough two-dimensional views to generate a complete three-dimensional (3-D) reconstruction. However, interactions between the sample and the air-water interface (AWI) that occur during vitrification often bias the views of the sample, a phenomenon termed preferred orientation, limiting our ability to obtain 3-D reconstructions. Surfactants are often used as sample additives to prevent AWI-induced deterioration, but no general strategy exists for surfactant choice, requiring laborious screening for each sample. To circumvent these issues, we developed SurfACT, a cocktail of diverse surfactants with distinct physicochemical properties that limits AWI-dependent sample denaturation and orientation bias, while mitigating individual surfactant-specific drawbacks. Here we demonstrate SurfACT’s effectiveness with four proteins plagued by AWI-induced issues, including two species of hemagglutinin (HA), molybdenum-iron protein (MoFeP) from the nitrogenase enzyme, and aldolase. All four samples show drastically improved viewing distribution and map completeness when SurfACT is applied. Cryogenic electron tomography demonstrates that SurfACT redistributes particles from the AWI into the bulk ice, driving signal recovery and inhibiting denaturation. This versatile sample additive minimizes sample-specific screening and expands the capabilities and range of suitable samples for cryoEM.
Open AccessA Surfactant Cocktail Overcomes Air-Water Interface Artifacts in Single-Particle CryoEM
Single-particle cryogenic electron microscopy (cryoEM) is a widely used technique for structure determination of biomacromolecules to near-atomic resolution. Random distributions of these molecules in vitrified ice are necessary to accumulate enough two-dimensional views to generate a complete three-dimensional (3-D) reconstruction. However, interactions between the sample and the air-water interface (AWI) that occur during vitrification often bias the views of the sample, a phenomenon termed preferred orientation, limiting our ability to obtain 3-D reconstructions. Surfactants are often used as sample additives to prevent AWI-induced deterioration, but no general strategy exists for surfactant choice, requiring laborious screening for each sample. To circumvent these issues, we developed SurfACT, a cocktail of diverse surfactants with distinct physicochemical properties that limits AWI-dependent sample denaturation and orientation bias, while mitigating individual surfactant-specific drawbacks. Here we demonstrate SurfACT’s effectiveness with four proteins plagued by AWI-induced issues, including two species of hemagglutinin (HA), molybdenum-iron protein (MoFeP) from the nitrogenase enzyme, and aldolase. All four samples show drastically improved viewing distribution and map completeness when SurfACT is applied. Cryogenic electron tomography demonstrates that SurfACT redistributes particles from the AWI into the bulk ice, driving signal recovery and inhibiting denaturation. This versatile sample additive minimizes sample-specific screening and expands the capabilities and range of suitable samples for cryoEM.
- Open Access
- 14 April 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 1-11
Preparation of oxygen-sensitive proteins for high-resolution cryoEM structure determination using blot-free vitrification
High-quality grid preparation for single-particle cryogenic electron microscopy (cryoEM) remains a bottleneck for routinely obtaining high-resolution structures. The issues that arise from traditional grid preparation workflows are particularly exacerbated for oxygen-sensitive proteins, including metalloproteins, whereby oxygen-induced damage and alteration of oxidation states can result in protein inactivation, denaturation, and/or aggregation. Indeed, 99% of the current structures in the EMBD were prepared aerobically and limited successes for anaerobic cryoEM grid preparation exist. Current practices for anaerobic grid preparation involve a vitrification device located in an anoxic chamber, which presents significant challenges including temperature and humidity control, optimization of freezing conditions, costs for purchase and operation, as well as accessibility. Here, we present a streamlined approach that allows for the vitrification of oxygen-sensitive proteins in reduced states using an automated blot-free grid vitrification device – the SPT Labtech chameleon. This robust workflow allows for high-resolution structure determination of dynamic, oxygen-sensitive proteins, of varying complexity and molecular weight.
- 14 April 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 1-11
Open AccessPreparation of oxygen-sensitive proteins for high-resolution cryoEM structure determination using blot-free vitrification
High-quality grid preparation for single-particle cryogenic electron microscopy (cryoEM) remains a bottleneck for routinely obtaining high-resolution structures. The issues that arise from traditional grid preparation workflows are particularly exacerbated for oxygen-sensitive proteins, including metalloproteins, whereby oxygen-induced damage and alteration of oxidation states can result in protein inactivation, denaturation, and/or aggregation. Indeed, 99% of the current structures in the EMBD were prepared aerobically and limited successes for anaerobic cryoEM grid preparation exist. Current practices for anaerobic grid preparation involve a vitrification device located in an anoxic chamber, which presents significant challenges including temperature and humidity control, optimization of freezing conditions, costs for purchase and operation, as well as accessibility. Here, we present a streamlined approach that allows for the vitrification of oxygen-sensitive proteins in reduced states using an automated blot-free grid vitrification device – the SPT Labtech chameleon. This robust workflow allows for high-resolution structure determination of dynamic, oxygen-sensitive proteins, of varying complexity and molecular weight.
- Open Access
Preparation of oxygen-sensitive proteins for high-resolution cryoEM structure determination using (an)aerobic blot-free vitrification
High-quality grid preparation for single-particle cryogenic electron microscopy (cryoEM) remains a bottleneck for routinely obtaining high-resolution structures. The issues that arise from traditional grid preparation workflows are particularly exacerbated for oxygen-sensitive proteins, including metalloproteins, whereby oxygen-induced damage and alteration of oxidation states can result in protein inactivation, denaturation, and/or aggregation. Indeed, 99% of the current structures in the EMBD were prepared aerobically and limited successes for anaerobic cryoEM grid preparation exist. Current practices for anaerobic grid preparation involve a vitrification device located in an anoxic chamber, which presents significant challenges including temperature and humidity control, optimization of freezing conditions, costs for purchase and operation, as well as accessibility. Here, we present a streamlined approach that allows for the (an)aerobic vitrification of oxygen-sensitive proteins using an automated aerobic blot-free grid vitrification device – the SPT Labtech chameleon. This robust workflow allows for high-resolution structure determination of dynamic, oxygen-sensitive proteins, of varying complexity and molecular weight.
Open AccessPreparation of oxygen-sensitive proteins for high-resolution cryoEM structure determination using (an)aerobic blot-free vitrification
High-quality grid preparation for single-particle cryogenic electron microscopy (cryoEM) remains a bottleneck for routinely obtaining high-resolution structures. The issues that arise from traditional grid preparation workflows are particularly exacerbated for oxygen-sensitive proteins, including metalloproteins, whereby oxygen-induced damage and alteration of oxidation states can result in protein inactivation, denaturation, and/or aggregation. Indeed, 99% of the current structures in the EMBD were prepared aerobically and limited successes for anaerobic cryoEM grid preparation exist. Current practices for anaerobic grid preparation involve a vitrification device located in an anoxic chamber, which presents significant challenges including temperature and humidity control, optimization of freezing conditions, costs for purchase and operation, as well as accessibility. Here, we present a streamlined approach that allows for the (an)aerobic vitrification of oxygen-sensitive proteins using an automated aerobic blot-free grid vitrification device – the SPT Labtech chameleon. This robust workflow allows for high-resolution structure determination of dynamic, oxygen-sensitive proteins, of varying complexity and molecular weight.
- Open Access
Tuning ice thickness using the chameleon for high-quality cryoEM data collection
Advances in single-particle cryogenic electron microscopy (cryoEM) now allow for routine structure determination of well-behaved biological specimens to high-resolution. Despite advances in the electron microscope, direct electron detectors, and data processing software, the preparation of high-quality grids with thin layers of vitreous ice containing the specimen of interest in random orientations remains a critical bottleneck for many projects. Although numerous efforts have been dedicated to overcoming hurdles frequently encountered during specimen vitrification using traditional blot-and-plunge specimen preparation techniques, the development of blot-free grid preparation devices provide a unique opportunity to carefully tune ice thickness, particle density, and specimen behavior during the vitrification process for improvements in image quality. Here, we describe critical steps of high-quality grid preparation using a SPT Labtech chameleon, evaluation of grid quality/ice thickness using the chameleon software, high-throughput imaging in the electron microscope, and recommend steps for troubleshooting grid preparation when standard parameters fail to yield suitable specimen. Video Link: Contents of this manuscript are available as a video tutorial. This video can be found here
Open AccessTuning ice thickness using the chameleon for high-quality cryoEM data collection
Advances in single-particle cryogenic electron microscopy (cryoEM) now allow for routine structure determination of well-behaved biological specimens to high-resolution. Despite advances in the electron microscope, direct electron detectors, and data processing software, the preparation of high-quality grids with thin layers of vitreous ice containing the specimen of interest in random orientations remains a critical bottleneck for many projects. Although numerous efforts have been dedicated to overcoming hurdles frequently encountered during specimen vitrification using traditional blot-and-plunge specimen preparation techniques, the development of blot-free grid preparation devices provide a unique opportunity to carefully tune ice thickness, particle density, and specimen behavior during the vitrification process for improvements in image quality. Here, we describe critical steps of high-quality grid preparation using a SPT Labtech chameleon, evaluation of grid quality/ice thickness using the chameleon software, high-throughput imaging in the electron microscope, and recommend steps for troubleshooting grid preparation when standard parameters fail to yield suitable specimen. Video Link: Contents of this manuscript are available as a video tutorial. This video can be found here
- Open Access
- 13 April 2023
- Published by Elsevier in Journal of Biological Chemistry
- Vol. 299 (3) , S303
Abstract 1360: CryoEM structures of the nitrogenase complex during catalytic turnover
- 13 April 2023
- Published by Elsevier in Journal of Biological Chemistry
- Vol. 299 (3) , S303
Open AccessAbstract 1360: CryoEM structures of the nitrogenase complex during catalytic turnover