Chengxi Lyu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chengxi Lyu has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Jiaxi Hu
China Academy of Building Research, Beijing, 100013, China
1 shared publication- Jiaxi Hu
School of Architecture, Tianjin University, Tianjin 300072, China
1 shared publication - Kairui Liu
School of Environment Science and Engineering, Tianjin University, Tianjin 300072, China
1 shared publication - Neng Zhu
School of Environmental Science and Engineering, Tianjin University, Tianjin 300350, China
1 shared publication Pengpeng Xu
China Academy of Building Research, Beijing, 100013, China
1 shared publicationRui Zhang
China Academy of Building Research, Beijing, 100013, China
1 shared publication
Latest Publications
- Open Access
- 5 May 2024
- Published by MDPI AG in Sustainability
- Vol. 16 (9) , 3864
Research on Summer Indoor Air Conditioning Design Parameters in Haikou City: A Field Study of Indoor Thermal Perception and Comfort
Escalating global climate change and the intensification of urban heatwaves have led to an increase in summer air conditioning cooling energy consumption. This phenomenon is particularly critical in tropical regions, as it may trigger an energy crisis. The rational setting of indoor thermal design parameters can help conserve energy to the maximum extent while ensuring thermal comfort for occupants. This study selected Haikou City, a unique tropical city in China, as the research location. Indoor environment measurements and a questionnaire survey were conducted with participants, and the outdoor thermal environment sensitivity, population attributes and differences in thermal sensation, thermal neutral temperature, and comfort range were calculated and analyzed. The following results were obtained. Based on the overall population, long-term residence, and temporary residence classification, the indoor thermal comfort needs of residents in tropical cities in Haikou were effectively identified. The actual thermal neutral temperature of the overall population is 25.7 °C, and 90% of the acceptable thermal comfort temperature range is 23.2 °C–28.0 °C. The actual thermal neutral temperature of the regular residents is 27.3 °C, and 90% of the acceptable thermal comfort temperature range is 23.3 °C–31.4 °C. The actual thermal neutral temperature of the temporary population is 25.5 °C, and 90% of the acceptable thermal comfort temperature range is 23.0 °C–28.0 °C. These research results have an important reference value for improving the setting of the temperature of air conditioning in tropical areas in summer and further reducing energy consumption, which is conducive to sustainable development.
- 5 May 2024
- Published by MDPI AG in Sustainability
- Vol. 16 (9) , 3864
Open AccessResearch on Summer Indoor Air Conditioning Design Parameters in Haikou City: A Field Study of Indoor Thermal Perception and Comfort
Escalating global climate change and the intensification of urban heatwaves have led to an increase in summer air conditioning cooling energy consumption. This phenomenon is particularly critical in tropical regions, as it may trigger an energy crisis. The rational setting of indoor thermal design parameters can help conserve energy to the maximum extent while ensuring thermal comfort for occupants. This study selected Haikou City, a unique tropical city in China, as the research location. Indoor environment measurements and a questionnaire survey were conducted with participants, and the outdoor thermal environment sensitivity, population attributes and differences in thermal sensation, thermal neutral temperature, and comfort range were calculated and analyzed. The following results were obtained. Based on the overall population, long-term residence, and temporary residence classification, the indoor thermal comfort needs of residents in tropical cities in Haikou were effectively identified. The actual thermal neutral temperature of the overall population is 25.7 °C, and 90% of the acceptable thermal comfort temperature range is 23.2 °C–28.0 °C. The actual thermal neutral temperature of the regular residents is 27.3 °C, and 90% of the acceptable thermal comfort temperature range is 23.3 °C–31.4 °C. The actual thermal neutral temperature of the temporary population is 25.5 °C, and 90% of the acceptable thermal comfort temperature range is 23.0 °C–28.0 °C. These research results have an important reference value for improving the setting of the temperature of air conditioning in tropical areas in summer and further reducing energy consumption, which is conducive to sustainable development.
- Open Access
- 4 January 2023
- Published by Frontiers Media SA in Frontiers in Ecology and Evolution
- Vol. 10
Optimizing the evaluation model of green building management based on the concept of urban ecology and environment
Eco-city and green building are the global development strategies today. In order to improve the management level of green buildings in the urbanization process, a reciprocal symbiosis evaluation index model is proposed based on the theory of urban ecology. On this basis, the collaborative relationship model between Eco-city and green building is established, and the green building management framework based on the collaborative theory is constructed. The expert survey method was used to determine the evaluation indicators and analyze the relationship between various city subsystems. Then, the analytic hierarchy process is used to build a three-level evaluation index system, including the target layer, the criterion layer, and the index layer. The weight of the evaluation index system is calculated by combining of the chromatography method and the entropy weight method, and a scientific evaluation index system is established. The gray comprehensive evaluation method is used to evaluate the construction of the green building management system. Based on the index system, the analytic hierarchy process is used to calculate different weight coefficients, which makes the evaluation model easy to use and lays a foundation for subsequent research.
- 4 January 2023
- Published by Frontiers Media SA in Frontiers in Ecology and Evolution
- Vol. 10
Open AccessOptimizing the evaluation model of green building management based on the concept of urban ecology and environment
Eco-city and green building are the global development strategies today. In order to improve the management level of green buildings in the urbanization process, a reciprocal symbiosis evaluation index model is proposed based on the theory of urban ecology. On this basis, the collaborative relationship model between Eco-city and green building is established, and the green building management framework based on the collaborative theory is constructed. The expert survey method was used to determine the evaluation indicators and analyze the relationship between various city subsystems. Then, the analytic hierarchy process is used to build a three-level evaluation index system, including the target layer, the criterion layer, and the index layer. The weight of the evaluation index system is calculated by combining of the chromatography method and the entropy weight method, and a scientific evaluation index system is established. The gray comprehensive evaluation method is used to evaluate the construction of the green building management system. Based on the index system, the analytic hierarchy process is used to calculate different weight coefficients, which makes the evaluation model easy to use and lays a foundation for subsequent research.