Karim Hamaoui
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Karim Hamaoui has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Vassilios Papalois
Imperial College Renal and Transplant Centre, Imperial College Healthcare NHS Trust, Hammersmith Hospital, Du Cane Road, London W12 0HS, UK
2 shared publications - Apostolos Prionas
Department of Surgery and Cancer, Imperial College London, London SW7 2AZ, UK
1 shared publication - Bynvant Sandhu
Department of Surgery and Cancer, Imperial College London, London SW7 2AZ, UK
1 shared publication - Konstantinos Vanezis
Department of Surgery and Cancer, Imperial College London, London W12 0HS, UK
1 shared publication - Nagy Habib
Department of Surgery & Cancer, Imperial College London, W12 0NN London, UK; MiNA Therapeutics Ltd, W12 0BZ London, UK
1 shared publication - Natalie Vallant
Department of Paediatric Surgery, Evelina London Children's Hospital, London, SE1 7EH, UK
1 shared publication
Latest Publications
- Open Access
- 5 June 2024
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 25 (11) , 6231
The Effect of Interleukin-10 Immunotherapy on Renal Ischemia-Reperfusion Injury: A Systematic Review and Meta-Analysis of Preclinical Studies
Renal ischemia-reperfusion is a common cause of acute kidney injury leading to significant morbidity and mortality. There are no effective treatments available in clinical practice. This meta-analysis aims to assess the effect of IL-10 immunotherapy on renal ischemia-reperfusion injury. Medline, Embase, Cochrane-library, Google Scholar and clinicaltrials.gov were searched up to 31 March 2023. Preclinical and clinical interventional studies investigating IL-10 immunotherapy for renal ischemia-reperfusion were eligible for inclusion. The primary endpoint was renal function (serum creatinine) following ischemia-reperfusion. The secondary endpoints included mitochondrial integrity, cellular proliferation, regulated cell death (TUNEL assay), expression of inflammatory cytokines (TNF-α, IL-6 and IL-1β), M1/M2 macrophage polarization, tissue integrity (tubular injury score), long-term kidney fibrosis (fibrotic area %) and adverse events (pulmonary toxicity, cardiotoxicity hepatotoxicity). The search returned 861 records. From these, 16 full texts were screened and subsequently, seven animal studies, corresponding to a population of 268 mice/rats, were included. Compared to the control treatment, IL-10 immunotherapy reduced serum creatinine more effectively within 24 h of administration (95% CI: −9.177, −5.601, I2 = 22.42%). IL-10 immunotherapy promoted mitochondrial integrity and cellular proliferation and reduced regulated cell death (95% CI: −11.000, −4.184, I2 = 74.94%). It decreased the expression of TNF-α, IL-6 and IL-1β, led to M2 polarization of the local macrophages, reduced tubular injury score (95% CI: −8.917, −5.755, I2 = 22.71%), and long-term kidney fibrosis (95% CI: −6.963, −3.438, I2 = 0%). No adverse outcomes were captured. In Conclusion, IL-10 immunotherapy safely improves outcomes in animal models of renal ischemia-reperfusion; the translational potential of IL-10 immunotherapy needs to be further investigated in clinical trials.
- 5 June 2024
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 25 (11) , 6231
Open AccessThe Effect of Interleukin-10 Immunotherapy on Renal Ischemia-Reperfusion Injury: A Systematic Review and Meta-Analysis of Preclinical Studies
Renal ischemia-reperfusion is a common cause of acute kidney injury leading to significant morbidity and mortality. There are no effective treatments available in clinical practice. This meta-analysis aims to assess the effect of IL-10 immunotherapy on renal ischemia-reperfusion injury. Medline, Embase, Cochrane-library, Google Scholar and clinicaltrials.gov were searched up to 31 March 2023. Preclinical and clinical interventional studies investigating IL-10 immunotherapy for renal ischemia-reperfusion were eligible for inclusion. The primary endpoint was renal function (serum creatinine) following ischemia-reperfusion. The secondary endpoints included mitochondrial integrity, cellular proliferation, regulated cell death (TUNEL assay), expression of inflammatory cytokines (TNF-α, IL-6 and IL-1β), M1/M2 macrophage polarization, tissue integrity (tubular injury score), long-term kidney fibrosis (fibrotic area %) and adverse events (pulmonary toxicity, cardiotoxicity hepatotoxicity). The search returned 861 records. From these, 16 full texts were screened and subsequently, seven animal studies, corresponding to a population of 268 mice/rats, were included. Compared to the control treatment, IL-10 immunotherapy reduced serum creatinine more effectively within 24 h of administration (95% CI: −9.177, −5.601, I2 = 22.42%). IL-10 immunotherapy promoted mitochondrial integrity and cellular proliferation and reduced regulated cell death (95% CI: −11.000, −4.184, I2 = 74.94%). It decreased the expression of TNF-α, IL-6 and IL-1β, led to M2 polarization of the local macrophages, reduced tubular injury score (95% CI: −8.917, −5.755, I2 = 22.71%), and long-term kidney fibrosis (95% CI: −6.963, −3.438, I2 = 0%). No adverse outcomes were captured. In Conclusion, IL-10 immunotherapy safely improves outcomes in animal models of renal ischemia-reperfusion; the translational potential of IL-10 immunotherapy needs to be further investigated in clinical trials.
- Open Access
- 5 May 2024
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 25 (9) , 5038
Delivery of Mesenchymal Stem Cells during Hypothermic Machine Perfusion in a Translational Kidney Perfusion Study
In transplantation, hypothermic machine perfusion (HMP) has been shown to be superior to static cold storage (SCS) in terms of functional outcomes. Ex vivo machine perfusion offers the possibility to deliver drugs or other active substances, such as Mesenchymal Stem Cells (MSCs), directly into an organ without affecting the recipient. MSCs are multipotent, self-renewing cells with tissue-repair capacities, and their application to ameliorate ischemia- reperfusion injury (IRI) is being investigated in several preclinical and clinical studies. The aim of this study was to introduce MSCs into a translational model of hypothermic machine perfusion and to test the efficiency and feasibility of this method. Methods: three rodent kidneys, six porcine kidneys and three human kidneys underwent HMP with 1–5 × 106 labelled MSCs within respective perfusates. Only porcine kidneys were compared to a control group of 6 kidneys undergoing HMP without MSCs, followed by mimicked reperfusion with whole blood at 37 °C for 2 h for all 12 kidneys. Reperfusion perfusate samples were analyzed for levels of NGAL and IL-β by ELISA. Functional parameters, including urinary output, oxygen consumption and creatinine clearance, were compared and found to be similar between the MSC treatment group and the control group in the porcine model. IL-1β levels were higher in perfusate and urine samples in the MSC group, with a median of 285.3 ng/mL (IQR 224.3–407.8 ng/mL) vs. 209.2 ng/mL (IQR 174.9–220.1), p = 0.51 and 105.3 ng/mL (IQR 71.03–164.7 ng/mL) vs. 307.7 ng/mL (IQR 190.9–349.6 ng/mL), p = 0.16, respectively. MSCs could be traced within the kidneys in all models using widefield microscopy after HMP. The application of Mesenchymal Stem Cells in an ex vivo hypothermic machine perfusion setting is feasible, and MSCs can be delivered into the kidney grafts during HMP. Functional parameters during mimicked reperfusion were not altered in treated kidney grafts. Changes in levels of IL-1β suggest that MSCs might have an effect on the kidney grafts, and whether this leads to a positive or a negative outcome on IRI in transplantation needs to be determined in further experiments.
- 5 May 2024
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 25 (9) , 5038
Open AccessDelivery of Mesenchymal Stem Cells during Hypothermic Machine Perfusion in a Translational Kidney Perfusion Study
In transplantation, hypothermic machine perfusion (HMP) has been shown to be superior to static cold storage (SCS) in terms of functional outcomes. Ex vivo machine perfusion offers the possibility to deliver drugs or other active substances, such as Mesenchymal Stem Cells (MSCs), directly into an organ without affecting the recipient. MSCs are multipotent, self-renewing cells with tissue-repair capacities, and their application to ameliorate ischemia- reperfusion injury (IRI) is being investigated in several preclinical and clinical studies. The aim of this study was to introduce MSCs into a translational model of hypothermic machine perfusion and to test the efficiency and feasibility of this method. Methods: three rodent kidneys, six porcine kidneys and three human kidneys underwent HMP with 1–5 × 106 labelled MSCs within respective perfusates. Only porcine kidneys were compared to a control group of 6 kidneys undergoing HMP without MSCs, followed by mimicked reperfusion with whole blood at 37 °C for 2 h for all 12 kidneys. Reperfusion perfusate samples were analyzed for levels of NGAL and IL-β by ELISA. Functional parameters, including urinary output, oxygen consumption and creatinine clearance, were compared and found to be similar between the MSC treatment group and the control group in the porcine model. IL-1β levels were higher in perfusate and urine samples in the MSC group, with a median of 285.3 ng/mL (IQR 224.3–407.8 ng/mL) vs. 209.2 ng/mL (IQR 174.9–220.1), p = 0.51 and 105.3 ng/mL (IQR 71.03–164.7 ng/mL) vs. 307.7 ng/mL (IQR 190.9–349.6 ng/mL), p = 0.16, respectively. MSCs could be traced within the kidneys in all models using widefield microscopy after HMP. The application of Mesenchymal Stem Cells in an ex vivo hypothermic machine perfusion setting is feasible, and MSCs can be delivered into the kidney grafts during HMP. Functional parameters during mimicked reperfusion were not altered in treated kidney grafts. Changes in levels of IL-1β suggest that MSCs might have an effect on the kidney grafts, and whether this leads to a positive or a negative outcome on IRI in transplantation needs to be determined in further experiments.