Kevin B. Fournier
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kevin B. Fournier has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
- Christopher W. Mauche
Lawrence Livermore National Laboratory 7000 East Avenue L-473 94550 Livermore CA USA
3 shared publications - C. D. Newlander
Gray Research, Inc. 2 , 655 Discovery Drive, Suite 300, Huntsville, Alabama 35806, USA
2 shared publications - Duane A. Liedahl
Physics Department Lawrence Livermore National Laboratory P.O. Box 808 L-41 94550 Livermore CA USA
2 shared publications - J. H. Fisher
Gray Research, Inc. 2 , 655 Discovery Drive, Suite 300, Huntsville, Alabama 35806, USA
2 shared publications M. J. May
Lawrence Livermore National Laboratory 1 , Livermore, California 94551, USA
2 shared publicationsR. Horton
Gray Research, Inc. 3 , Huntsville, Alabama 35806, USA
2 shared publications
Latest Publications
- 31 August 2012
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 83 (10) , 10E136
The x-ray source application test cassette for radiation exposures at the OMEGA laser
We have designed a sample cassette that can be used to position up to six samples in the OMEGA laser chamber. The cassette accommodates round samples up to 38.1 mm (1.5″) in diameter and square samples up to 27 mm on a side, any of which can be up to 12.7 mm thick. Smaller specimens are centered with spacers. The test cassette allows each sample to have a unique filter scheme, with multiple filter regions in front of each sample. This paper will present mechanical design considerations and operational aspects of the x-ray source application cassette.
- 31 August 2012
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 83 (10) , 10E136
The x-ray source application test cassette for radiation exposures at the OMEGA laser
We have designed a sample cassette that can be used to position up to six samples in the OMEGA laser chamber. The cassette accommodates round samples up to 38.1 mm (1.5″) in diameter and square samples up to 27 mm on a side, any of which can be up to 12.7 mm thick. Smaller specimens are centered with spacers. The test cassette allows each sample to have a unique filter scheme, with multiple filter regions in front of each sample. This paper will present mechanical design considerations and operational aspects of the x-ray source application cassette.
- 1 August 2010
- Published by AIP Publishing in Physics of Plasmas
- Vol. 17 (8) , 082701
Multi-keV x-ray source development experiments on the National Ignition Facility
We report results from a five shot campaign carried out with Ar–Xe gas-filled targets at the National Ignition Facility (NIF). The targets were shot with ≈350 kJ of laser energy delivered with a 5 ns trapezoidal laser pulse. We report measured x-ray output from the target in different spectral bands both below and above 1.5 keV photon energies: We find yields of ≈20.5 kJ/sr with peak x-ray power approaching 4 TW/sr over all energies, as measured for the unique viewing angle of our detector, and ≈3.6 kJ/sr with peak x-ray power of 1 TW/sr for x-rays with energies . This is a laser-to-x-ray conversion efficiency of for isotropic x-rays with energies . Laser energy reflected by the target plasma for both inner and outer-cone beams is measured and found to be small, between 1% and 4% of the drive energy. The energy emitted in hard x-rays (with energies ) is measured and found to be ≈1 J/sr. Two-dimensional imaging of the target plasma during the laser pulse confirms a fast, volumetric heating of the entire target, resulting in efficient laser-to-x-ray conversion. Postshot simulations with a two-dimensional radiation-hydrodynamics code reproduce well the observed x-ray flux and fluence, backscattered light, and bulk target motion.- 1 August 2010
- Published by AIP Publishing in Physics of Plasmas
- Vol. 17 (8) , 082701
Multi-keV x-ray source development experiments on the National Ignition Facility
We report results from a five shot campaign carried out with Ar–Xe gas-filled targets at the National Ignition Facility (NIF). The targets were shot with ≈350 kJ of laser energy delivered with a 5 ns trapezoidal laser pulse. We report measured x-ray output from the target in different spectral bands both below and above 1.5 keV photon energies: We find yields of ≈20.5 kJ/sr with peak x-ray power approaching 4 TW/sr over all energies, as measured for the unique viewing angle of our detector, and ≈3.6 kJ/sr with peak x-ray power of 1 TW/sr for x-rays with energies . This is a laser-to-x-ray conversion efficiency of for isotropic x-rays with energies . Laser energy reflected by the target plasma for both inner and outer-cone beams is measured and found to be small, between 1% and 4% of the drive energy. The energy emitted in hard x-rays (with energies ) is measured and found to be ≈1 J/sr. Two-dimensional imaging of the target plasma during the laser pulse confirms a fast, volumetric heating of the entire target, resulting in efficient laser-to-x-ray conversion. Postshot simulations with a two-dimensional radiation-hydrodynamics code reproduce well the observed x-ray flux and fluence, backscattered light, and bulk target motion.- 1 July 2010
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 81 (7) , 075113
A test cassette for x-ray-exposure experiments at the National Ignition Facility
We present the design and operation of a test cassette for exposure of samples to radiation environments at the National Ignition Facility. The cassette provides options for square and round samples and exposure areas; the cassette provides for multiple levels of filtration on a single sample, which allows dynamic range in experiments. The samples had normal lines of sight to the x-ray source in order to have uniform x-ray illumination. The incident x-radiation onto the samples was determined by the choice of filter thicknesses and materials. The samples were held at precise locations, accurate to within a few hundred microns, in the target chamber in order to have a known fluence incident. In the cassette, the samples were held in place in such a way that a minimal “line contact” allows them to have the maximal mechanical response to the x-ray load. We present postshot images of the debris found on films used for filters, and pre- and postexposure specimens.
- 1 July 2010
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 81 (7) , 075113
A test cassette for x-ray-exposure experiments at the National Ignition Facility
We present the design and operation of a test cassette for exposure of samples to radiation environments at the National Ignition Facility. The cassette provides options for square and round samples and exposure areas; the cassette provides for multiple levels of filtration on a single sample, which allows dynamic range in experiments. The samples had normal lines of sight to the x-ray source in order to have uniform x-ray illumination. The incident x-radiation onto the samples was determined by the choice of filter thicknesses and materials. The samples were held at precise locations, accurate to within a few hundred microns, in the target chamber in order to have a known fluence incident. In the cassette, the samples were held in place in such a way that a minimal “line contact” allows them to have the maximal mechanical response to the x-ray load. We present postshot images of the debris found on films used for filters, and pre- and postexposure specimens.
- 30 June 2006
- Published by Elsevier in Journal of Quantitative Spectroscopy and Radiative Transfer
- Vol. 99 (1-3) , 186-198
Electron-density scaling of conversion efficiency of laser energy into L-shell X-rays
- 30 June 2006
- Published by Elsevier in Journal of Quantitative Spectroscopy and Radiative Transfer
- Vol. 99 (1-3) , 186-198
Electron-density scaling of conversion efficiency of laser energy into L-shell X-rays
- Open Access
The Fe XXII I(11.92 A)/I(11.77 A) Density Diagnostic Applied to the Chandra High Energy Transmission Grating Spectrum of EX Hydrae
Using the Livermore X-ray Spectral Synthesizer, which calculates spectral models of highly charged ions based primarily on HULLAC atomic data, we investigate the temperature, density, and photoexcitation dependence of the I(11.92 A)/I(11.77 A) line ratio of Fe XXII. We find that this line ratio has a critical density n_c \approx 5x10^13 cm^-3, is approximately 0.3 at low densities and 1.5 at high densities, and is very insensitive to temperature and photoexcitation, so is a useful density diagnostic for sources like magnetic cataclysmic variables in which the plasma densities are high and the efficacy of the He-like ion density diagnostic is compromised by the presence of a bright ultraviolet continuum. Applying this diagnostic to the Chandra High Energy Transmission Grating spectrum of the intermediate polar EX Hya, we find that the electron density of its T_e \approx 12 MK plasma is n_e = 1.0^{+2.0}_{-0.5} x 10^14 cm^-3, orders of magnitude greater than that typically observed in the Sun or other late-type stars.
Open AccessThe Fe XXII I(11.92 A)/I(11.77 A) Density Diagnostic Applied to the Chandra High Energy Transmission Grating Spectrum of EX Hydrae
Using the Livermore X-ray Spectral Synthesizer, which calculates spectral models of highly charged ions based primarily on HULLAC atomic data, we investigate the temperature, density, and photoexcitation dependence of the I(11.92 A)/I(11.77 A) line ratio of Fe XXII. We find that this line ratio has a critical density n_c \approx 5x10^13 cm^-3, is approximately 0.3 at low densities and 1.5 at high densities, and is very insensitive to temperature and photoexcitation, so is a useful density diagnostic for sources like magnetic cataclysmic variables in which the plasma densities are high and the efficacy of the He-like ion density diagnostic is compromised by the presence of a bright ultraviolet continuum. Applying this diagnostic to the Chandra High Energy Transmission Grating spectrum of the intermediate polar EX Hya, we find that the electron density of its T_e \approx 12 MK plasma is n_e = 1.0^{+2.0}_{-0.5} x 10^14 cm^-3, orders of magnitude greater than that typically observed in the Sun or other late-type stars.
- 10 November 2001
- Published by American Astronomical Society in The Astrophysical Journal
- Vol. 561 (2) , 1144-1153
Electron‐Density–dependent Extreme‐Ultraviolet Intensity Ratios from L‐Shell Iron Ions in the Frascati Tokamak Upgrade
- 10 November 2001
- Published by American Astronomical Society in The Astrophysical Journal
- Vol. 561 (2) , 1144-1153
Electron‐Density–dependent Extreme‐Ultraviolet Intensity Ratios from L‐Shell Iron Ions in the Frascati Tokamak Upgrade
- Open Access
- 20 October 2001
- Published by American Astronomical Society in The Astrophysical Journal
- Vol. 560 (2) , 992-996
First Application of the FexviiI(17.10 A)/I(17.05 A) Line Ratio to Constrain the Plasma Density of a Cosmic X‐Ray Source
We show that the Fe XVII I(17.10 A)/I(17.05 A) line ratio observed in the Chandra HETG spectrum of the intermediate polar EX Hydrae is significantly smaller than that observed in the Sun or other late-type stars. Using the Livermore X-ray Spectral Synthesizer, which calculates spectral models of highly charged ions based on HULLAC atomic data, we find that the observed I(17.10 A)/I(17.05 A) line ratio can be explained if the plasma density n_e > 3x10^{14} cm^{-3}. However, if photoexcitation is included in the level population kinetics, the line ratio can be explained for any density if the photoexcitation temperature T_bb > 55 kK. For photoexcitation to dominate the Fe XVII level population kinetics, the relative size of the hotspot on the white dwarf surface must be f < 2%. This constraint and the observed X-ray flux requires a density n > 2x10^{14} cm^{-3} for the post-shock flow. Either way, then, the Chandra HETG spectrum of EX Hya requires a plasma density which is orders of magnitude greater than that observed in the Sun or other late-type stars.
- 20 October 2001
- Published by American Astronomical Society in The Astrophysical Journal
- Vol. 560 (2) , 992-996
Open AccessFirst Application of the FexviiI(17.10 A)/I(17.05 A) Line Ratio to Constrain the Plasma Density of a Cosmic X‐Ray Source
We show that the Fe XVII I(17.10 A)/I(17.05 A) line ratio observed in the Chandra HETG spectrum of the intermediate polar EX Hydrae is significantly smaller than that observed in the Sun or other late-type stars. Using the Livermore X-ray Spectral Synthesizer, which calculates spectral models of highly charged ions based on HULLAC atomic data, we find that the observed I(17.10 A)/I(17.05 A) line ratio can be explained if the plasma density n_e > 3x10^{14} cm^{-3}. However, if photoexcitation is included in the level population kinetics, the line ratio can be explained for any density if the photoexcitation temperature T_bb > 55 kK. For photoexcitation to dominate the Fe XVII level population kinetics, the relative size of the hotspot on the white dwarf surface must be f < 2%. This constraint and the observed X-ray flux requires a density n > 2x10^{14} cm^{-3} for the post-shock flow. Either way, then, the Chandra HETG spectrum of EX Hya requires a plasma density which is orders of magnitude greater than that observed in the Sun or other late-type stars.
- Open Access
First Application of the Fe XVII I(17.10 A)/I(17.05 A) Line Ratio to Constrain the Plasma Density of a Cosmic X-ray Source
We show that the Fe XVII I(17.10 A)/I(17.05 A) line ratio observed in the Chandra HETG spectrum of the intermediate polar EX Hydrae is significantly smaller than that observed in the Sun or other late-type stars. Using the Livermore X-ray Spectral Synthesizer, which calculates spectral models of highly charged ions based on HULLAC atomic data, we find that the observed I(17.10 A)/I(17.05 A) line ratio can be explained if the plasma density n_e > 3x10^{14} cm^{-3}. However, if photoexcitation is included in the level population kinetics, the line ratio can be explained for any density if the photoexcitation temperature T_bb > 55 kK. For photoexcitation to dominate the Fe XVII level population kinetics, the relative size of the hotspot on the white dwarf surface must be f < 2%. This constraint and the observed X-ray flux requires a density n > 2x10^{14} cm^{-3} for the post-shock flow. Either way, then, the Chandra HETG spectrum of EX Hya requires a plasma density which is orders of magnitude greater than that observed in the Sun or other late-type stars.
Open AccessFirst Application of the Fe XVII I(17.10 A)/I(17.05 A) Line Ratio to Constrain the Plasma Density of a Cosmic X-ray Source
We show that the Fe XVII I(17.10 A)/I(17.05 A) line ratio observed in the Chandra HETG spectrum of the intermediate polar EX Hydrae is significantly smaller than that observed in the Sun or other late-type stars. Using the Livermore X-ray Spectral Synthesizer, which calculates spectral models of highly charged ions based on HULLAC atomic data, we find that the observed I(17.10 A)/I(17.05 A) line ratio can be explained if the plasma density n_e > 3x10^{14} cm^{-3}. However, if photoexcitation is included in the level population kinetics, the line ratio can be explained for any density if the photoexcitation temperature T_bb > 55 kK. For photoexcitation to dominate the Fe XVII level population kinetics, the relative size of the hotspot on the white dwarf surface must be f < 2%. This constraint and the observed X-ray flux requires a density n > 2x10^{14} cm^{-3} for the post-shock flow. Either way, then, the Chandra HETG spectrum of EX Hya requires a plasma density which is orders of magnitude greater than that observed in the Sun or other late-type stars.