János M. Bozorádi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
János M. Bozorádi has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Péter Fürjes
Microsystems Laboratory, Institute of Technical Physics and Materials Science, HUN-REN Centre for Energy Research, 1121 Budapest, Hungary
4 shared publications G. Papp
Uzsoki Hospital Budapest Hungary
2 shared publications- Lilia Bató
Institute of Technical Physics and Materials Science, HUN-REN Centre for Energy Research, H-1121 Budapest, Hungary
2 shared publications - Orsolya Hakkel
Centre for Energy Research, Institute of Technical Physics and Materials Science, 1121 Budapest, Hungary
2 shared publications P. Fürjes
Inst. of Technical Physics and Materials Science Microsystems Lab HUN-REN Centre for Energy Research Budapest Hungary
2 shared publications- Zoltán Szabó
Inst. of Technical Physics and Materials Science, HUN-REN Centre for Energy Research
2 shared publications
Latest Publications
- Open Access
- 27 June 2026
- Published by MDPI AG in Micromachines
- Vol. 17 (7) , 782
From Simulation to Application: Droplet-Based Microfluidics for Thermal Targeting of Cancer Cells
This paper presents the development, fabrication, and characterization of a droplet-based microfluidic platform designed for precise local thermal treatment of cancer cells, with prospective chemical targeting as a future application. The workflow begins with a finite element model (FEM) using COMSOL Multiphysics 6.0 to characterize coupled hydrodynamic and thermal behavior, specifically analyzing temperature distributions across single-phase and three-phase regimes. Following the simulation, work has progressed to the fabrication of a microfluidic device and the characterization of its platinum heat source and temperature detector to ensure precise thermal control. To replicate realistic biochemical conditions, experiments have employed a three-phase configuration of oil, water, and fluorescent BSA solution. In the final stage, DX5-GFP MES-SA cancer cells have replaced the BSA solution to complete the measurements. To ensure reagent homogenization and consistent cellular exposure, a serpentine channel design was utilized to induce Dean vortices, which significantly enhanced internal mixing within the droplets. Fluorescence-loss experiments demonstrated that localized heating above ~60 °C induces irreversible thermal damage in both model proteins (fluorescent BSA) and cancer cells, establishing a proof-of-concept basis for precise thermal regulation at the single-droplet level. By deactivating specific thermo-sensitive proteins responsible for drug resistance, this integrated approach to thermal and hydrodynamic optimization enhances the efficacy of chemical stimuli and provides a robust platform for investigating the modulation of cellular defense mechanisms in future biotechnological applications. The platform holds significant potential for advancing precision oncology by enabling systematic, single-cell-level investigation of heat-shock-mediated drug sensitization, with long-term implications for overcoming multidrug resistance in aggressive cancer therapies.
- 27 June 2026
- Published by MDPI AG in Micromachines
- Vol. 17 (7) , 782
Open AccessFrom Simulation to Application: Droplet-Based Microfluidics for Thermal Targeting of Cancer Cells
This paper presents the development, fabrication, and characterization of a droplet-based microfluidic platform designed for precise local thermal treatment of cancer cells, with prospective chemical targeting as a future application. The workflow begins with a finite element model (FEM) using COMSOL Multiphysics 6.0 to characterize coupled hydrodynamic and thermal behavior, specifically analyzing temperature distributions across single-phase and three-phase regimes. Following the simulation, work has progressed to the fabrication of a microfluidic device and the characterization of its platinum heat source and temperature detector to ensure precise thermal control. To replicate realistic biochemical conditions, experiments have employed a three-phase configuration of oil, water, and fluorescent BSA solution. In the final stage, DX5-GFP MES-SA cancer cells have replaced the BSA solution to complete the measurements. To ensure reagent homogenization and consistent cellular exposure, a serpentine channel design was utilized to induce Dean vortices, which significantly enhanced internal mixing within the droplets. Fluorescence-loss experiments demonstrated that localized heating above ~60 °C induces irreversible thermal damage in both model proteins (fluorescent BSA) and cancer cells, establishing a proof-of-concept basis for precise thermal regulation at the single-droplet level. By deactivating specific thermo-sensitive proteins responsible for drug resistance, this integrated approach to thermal and hydrodynamic optimization enhances the efficacy of chemical stimuli and provides a robust platform for investigating the modulation of cellular defense mechanisms in future biotechnological applications. The platform holds significant potential for advancing precision oncology by enabling systematic, single-cell-level investigation of heat-shock-mediated drug sensitization, with long-term implications for overcoming multidrug resistance in aggressive cancer therapies.
- Open Access
Sensitivity Analysis of Localized Electrochemical Impedance Spectroscopy Towards Tomography-on-a-Chip
Electrical impedance measurements are traditionally macroscopic screening techniques designed to obtain information about the macroscopic internal structure of biological systems. In order to overcome the limitations that the technology detects, mainly with the bulk properties, a miniaturization is employed by developing a complex microfluidic system to achieve cell-scale information. In this work, a microelectrode array was incorporated into a microfluidic chip, allowing localized Electrochemical Impedance Spectroscopy (EIS) measurements, providing impedance data obtained in the spatial and frequency domains simultaneously. The height of the capillary in the microfluidic system was also systematically modified; hence, three types of channels with heights of 10 m, 30 m, and 50 m were developed and studied. The EIS data collection was implemented using two different strategies (two- and four-electrode techniques). Sensitivity analysis was conducted using a microbead solution, where the linear mapping of the number of microbeads along the channel was achieved by EIS. Based on the findings, a complete overview of each measurement implementation was obtained, which is well explained by the physical background presented in the paper. In the case where the capillary height (10 m) is comparable to the diameter of the microbeads (6 m), the four-electrode technique detected the beads in a wider frequency range (approximately between 500 Hz and 50 kHz), while the two-electrode technique detected the beads in a narrower frequency range (approximately between 30 kHz and 300 kHz) with correlation greater than 0.9. In all other cases, a medium (or weak) correlation was found between the impedance data and the longitudinal bead distribution. Based on the results, the technology is ready for further development and adaptation for cell culture purposes.Open AccessSensitivity Analysis of Localized Electrochemical Impedance Spectroscopy Towards Tomography-on-a-Chip
Electrical impedance measurements are traditionally macroscopic screening techniques designed to obtain information about the macroscopic internal structure of biological systems. In order to overcome the limitations that the technology detects, mainly with the bulk properties, a miniaturization is employed by developing a complex microfluidic system to achieve cell-scale information. In this work, a microelectrode array was incorporated into a microfluidic chip, allowing localized Electrochemical Impedance Spectroscopy (EIS) measurements, providing impedance data obtained in the spatial and frequency domains simultaneously. The height of the capillary in the microfluidic system was also systematically modified; hence, three types of channels with heights of 10 m, 30 m, and 50 m were developed and studied. The EIS data collection was implemented using two different strategies (two- and four-electrode techniques). Sensitivity analysis was conducted using a microbead solution, where the linear mapping of the number of microbeads along the channel was achieved by EIS. Based on the findings, a complete overview of each measurement implementation was obtained, which is well explained by the physical background presented in the paper. In the case where the capillary height (10 m) is comparable to the diameter of the microbeads (6 m), the four-electrode technique detected the beads in a wider frequency range (approximately between 500 Hz and 50 kHz), while the two-electrode technique detected the beads in a narrower frequency range (approximately between 30 kHz and 300 kHz) with correlation greater than 0.9. In all other cases, a medium (or weak) correlation was found between the impedance data and the longitudinal bead distribution. Based on the results, the technology is ready for further development and adaptation for cell culture purposes. - Open Access
Characterisation of Titanium-Oxide Thin Films for Efficient pH Sensing in Low-Power Electrochemical Systems
A compact electrochemical sensor module for pH detection was developed for potential integration into specialized devices used for live cell or tissue incubation, for applications in highly parallelized cell culture analysis, by incorporating Organ-on-Chip devices. This research focuses on the deposition, structural and chemical analysis, and functional characterization of different titanium-oxide layers with various compositions as potentially sensitive materials for pH sensing applications. The titanium-oxide layers were deposited using vacuum sputtering and atomic layer deposition at 100 °C and 300 °C, respectively. Transmission electron microscopy and X-ray photoelectron spectroscopy were utilized to determine the specific composition and structure of different titanium-oxide layers. These TiOx-functionalized electrodes were connected to the application-specific analog front-end chip of the low-power readout circuit for precise evaluation. The pH sensitivity of the differently modified electrodes, employing various TiOx materials, was evaluated using pH calibration solutions ranging from pH 6 to 8. Among the various deposition solutions, such as sputtering or high-temperature atomic layer deposition, the TiOx layer deposited using low-temperature atomic layer deposition proved more suitable for pH sensing applications, with a sensitivity of 54.8–56.7 mV/pH, which closely approximates the Nernstian response.
Open AccessCharacterisation of Titanium-Oxide Thin Films for Efficient pH Sensing in Low-Power Electrochemical Systems
A compact electrochemical sensor module for pH detection was developed for potential integration into specialized devices used for live cell or tissue incubation, for applications in highly parallelized cell culture analysis, by incorporating Organ-on-Chip devices. This research focuses on the deposition, structural and chemical analysis, and functional characterization of different titanium-oxide layers with various compositions as potentially sensitive materials for pH sensing applications. The titanium-oxide layers were deposited using vacuum sputtering and atomic layer deposition at 100 °C and 300 °C, respectively. Transmission electron microscopy and X-ray photoelectron spectroscopy were utilized to determine the specific composition and structure of different titanium-oxide layers. These TiOx-functionalized electrodes were connected to the application-specific analog front-end chip of the low-power readout circuit for precise evaluation. The pH sensitivity of the differently modified electrodes, employing various TiOx materials, was evaluated using pH calibration solutions ranging from pH 6 to 8. Among the various deposition solutions, such as sputtering or high-temperature atomic layer deposition, the TiOx layer deposited using low-temperature atomic layer deposition proved more suitable for pH sensing applications, with a sensitivity of 54.8–56.7 mV/pH, which closely approximates the Nernstian response.
- Open Access
- 1 January 2025
- Published by AMA Service GmbH
- p. 486-487
TP66 - Force measurement in Laparoscopic Stapler for Ex-Vivo Tissue Characterization
Minimally invasive surgical (MIS) procedures of the gastric tract often involve resection of tissues such as the bowel, colon or part of the stomach. Modern surgical trends point toward surgical robotics being more and more widely applied, but manual laparoscopy is still prevalent. We believe that gathering large quantities of mechanical data through tissue characterization is fundamental for the improvement of laparoscopic tools and procedures. A crucial feature of small-scale integrated measurement systems is the coverage of the sensor and the accompanying readout electronics. In our work we intended to test our proprietary MEMS force sensor developed by HUN-REN CER's Microsystems Lab for in-situ tissue characterization by integrating it into a stapler currently used in medical practice. Using a flexible printed circuit board (PCB) carrier and customized 3D printed enclosures, a series of stapler-compatible sensor casings were developed. These were tested both with hard cover used in our tabletop measurement system [1] as well as combining with polydimethylsiloxane (PDMS) to evaluate its effectiveness as a biocompatible sensor encapsulation.
- 1 January 2025
- Published by AMA Service GmbH
- p. 486-487
Open AccessTP66 - Force measurement in Laparoscopic Stapler for Ex-Vivo Tissue Characterization
Minimally invasive surgical (MIS) procedures of the gastric tract often involve resection of tissues such as the bowel, colon or part of the stomach. Modern surgical trends point toward surgical robotics being more and more widely applied, but manual laparoscopy is still prevalent. We believe that gathering large quantities of mechanical data through tissue characterization is fundamental for the improvement of laparoscopic tools and procedures. A crucial feature of small-scale integrated measurement systems is the coverage of the sensor and the accompanying readout electronics. In our work we intended to test our proprietary MEMS force sensor developed by HUN-REN CER's Microsystems Lab for in-situ tissue characterization by integrating it into a stapler currently used in medical practice. Using a flexible printed circuit board (PCB) carrier and customized 3D printed enclosures, a series of stapler-compatible sensor casings were developed. These were tested both with hard cover used in our tabletop measurement system [1] as well as combining with polydimethylsiloxane (PDMS) to evaluate its effectiveness as a biocompatible sensor encapsulation.
- Open Access
- 6 May 2024
- Published by MDPI AG in Proceedings
- Vol. 97 (1) , 209
Microfluidic Cuvette for Near-Infrared Spectroscopy
We intend to develop an in situ near-infrared spectroscopic solution for monitoring the nutrient composition (e.g., lactate concentration) in microfluidic channels of organ-on-chip devices. In this work, the effects of the geometry, surface quality, and architecture of the micro-volume cuvettes were characterized and optimized considering the signal-to-noise ratio and sensitivity of the proposed spectroscopic method in case of aqueous solutions. The applicability of the micro-volume near-infrared spectroscopy method using this specially designed microfluidic cuvette was proven.
- 6 May 2024
- Published by MDPI AG in Proceedings
- Vol. 97 (1) , 209
Open AccessMicrofluidic Cuvette for Near-Infrared Spectroscopy
We intend to develop an in situ near-infrared spectroscopic solution for monitoring the nutrient composition (e.g., lactate concentration) in microfluidic channels of organ-on-chip devices. In this work, the effects of the geometry, surface quality, and architecture of the micro-volume cuvettes were characterized and optimized considering the signal-to-noise ratio and sensitivity of the proposed spectroscopic method in case of aqueous solutions. The applicability of the micro-volume near-infrared spectroscopy method using this specially designed microfluidic cuvette was proven.
- Open Access
- 1 January 2024
- Published by AMA Service GmbH
- p. 317-318
PT4.238 - Characterization of Gastric Tissue Samples with MEMS Force Sensor Based Indentation method
Considering the actual requirements in laparoscopic as well as robotic surgical practices and the advancements in utilisation of artificial intelligences in data analysis and decision making, the need for tissue mechanical analysis is greater than ever. However, the necessary data is still hard to acquire due to the existing gap between medical and engineering professionals in daily practice. Since the chosen methods of tissue characterization vary widely, we designed our measurement setup so that it resembles clinical practice as closely as possible. [1] In our cooperation with the Uzsoki Hospital, we present the results of our measurement system developed for gastrointestinal tissue characterization. We aim this as a pioneer project to form a basis for larger, more targeted data collection to improve medical professionals' decision-making during surgical procedures.
- 1 January 2024
- Published by AMA Service GmbH
- p. 317-318
Open AccessPT4.238 - Characterization of Gastric Tissue Samples with MEMS Force Sensor Based Indentation method
Considering the actual requirements in laparoscopic as well as robotic surgical practices and the advancements in utilisation of artificial intelligences in data analysis and decision making, the need for tissue mechanical analysis is greater than ever. However, the necessary data is still hard to acquire due to the existing gap between medical and engineering professionals in daily practice. Since the chosen methods of tissue characterization vary widely, we designed our measurement setup so that it resembles clinical practice as closely as possible. [1] In our cooperation with the Uzsoki Hospital, we present the results of our measurement system developed for gastrointestinal tissue characterization. We aim this as a pioneer project to form a basis for larger, more targeted data collection to improve medical professionals' decision-making during surgical procedures.