Linus Leven
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Linus Leven has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Constantin Motel
Dental Clinic 2 – Department of Prosthodontics, Erlangen University Hospital, Erlangen, Germany
1 shared publication - Juergen Taxis
Department of Cranio-Maxillofacial Surgery, University Hospital Regensburg, 93053 Regensburg, Germany
1 shared publication - Lara Berger
Department of Prosthodontics, University Hospital Erlangen, Glückstrasse 11, 91054 Erlangen, Germany
1 shared publication - Manfred Wichmann
Department of Prosthodontics, Erlangen University Hospital, Friedrich-Alexander-University Erlangen-Nuremberg, Glueckstrasse 11, 91054 Erlangen, Germany
1 shared publication - Moritz Loehlein
Dental Clinic 2-Dental Prosthodontics, University Hospital Erlangen, Glueckstrasse 11, 91054 Erlangen, Germany
1 shared publication - Ragai Edward Matta
Department of Prosthodontics, Erlangen University Hospital, Friedrich-Alexander-University Erlangen-Nuremberg, Glueckstrasse 11, 91054 Erlangen, Germany
1 shared publication
Latest Publications
- Open Access
Stress Distribution within the Peri-Implant Bone for Different Implant Materials Obtained by Digital Image Correlation
Stress distribution and its magnitude during loading heavily influence the osseointegration of dental implants. Currently, no high-resolution, three-dimensional method of directly measuring these biomechanical processes in the peri-implant bone is available. The aim of this study was to measure the influence of different implant materials on stress distribution in the peri-implant bone. Using the three-dimensional ARAMIS camera system, surface strain in the peri-implant bone area was compared under simulated masticatory forces of 300 N in axial and non-axial directions for titanium implants and zirconia implants. The investigated titanium implants led to a more homogeneous stress distribution than the investigated zirconia implants. Non-axial forces led to greater surface strain on the peri-implant bone than axial forces. Thus, the implant material, implant system, and direction of force could have a significant influence on biomechanical processes and osseointegration within the peri-implant bone.
Open AccessStress Distribution within the Peri-Implant Bone for Different Implant Materials Obtained by Digital Image Correlation
Stress distribution and its magnitude during loading heavily influence the osseointegration of dental implants. Currently, no high-resolution, three-dimensional method of directly measuring these biomechanical processes in the peri-implant bone is available. The aim of this study was to measure the influence of different implant materials on stress distribution in the peri-implant bone. Using the three-dimensional ARAMIS camera system, surface strain in the peri-implant bone area was compared under simulated masticatory forces of 300 N in axial and non-axial directions for titanium implants and zirconia implants. The investigated titanium implants led to a more homogeneous stress distribution than the investigated zirconia implants. Non-axial forces led to greater surface strain on the peri-implant bone than axial forces. Thus, the implant material, implant system, and direction of force could have a significant influence on biomechanical processes and osseointegration within the peri-implant bone.