Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Edoardo De Cristo has a total of 36 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Research Trends in Thermal Comfort and Energy Efficiency in Buildings: An Editorial Overview

    by Luca Evangelisti, Edoardo De Cristo, Roberto De Lieto Vollaro

    The transition towards a low-carbon built environment requires buildings to satisfy multiple performance objectives simultaneously

  • Open Access

    Inverse Identification of Equivalent Thermophysical Properties for Building Energy Analysis Under Dynamic Boundary Conditions

    by Rune Barnkob, Paola Gori, Edoardo De Cristo, Luca Evangelisti, Gianluca Coltrinari, Claudia Fabiani, Anna Laura Pisello, Claudia Guattari

    The evaluation of building energy performance under dynamic conditions requires reliable estimates of the thermophysical properties of envelope components. In existing buildings, however, the properties of multilayer walls are often unknown or uncertain, limiting the applicability of detailed physical models. To address this issue, this study proposes an inverse modeling framework for identifying the equivalent thermophysical parameters of a multilayer wall through a simplified homogeneous one-dimensional conduction model. The equivalent parameters are determined by matching the inner-side dynamic thermal response of the homogeneous model to that of the actual multilayer structure under the same external excitation. The approach explicitly accounts for the role of inner boundary conditions, which govern both the identifiability of the equivalent parameters and the formulation of the inverse problem. Adiabatic, isothermal, and more general inner boundary conditions are analyzed to determine how many independent parameters can be reliably identified and which response variables should be used in the objective function. Synthetic datasets, generated via numerical simulations driven by real weather data, are first employed to assess the method and to quantify the effect of transient initialization. The framework is then applied to experimental measurements collected from a full-scale test room. The results show that, under adiabatic conditions, the wall dynamics can be accurately reproduced by identifying a single equivalent thermal diffusivity, whereas isothermal and near-isothermal conditions require the simultaneous estimation of thermal conductivity and volumetric heat capacity. Moreover, the analysis demonstrates that inverse formulations based on inner heat flux are significantly more robust than temperature-based formulations, particularly when the inner-surface temperature is weakly varying or tightly controlled, as commonly occurs in real buildings. In a nearly isothermal experimental case, the inverse identification failed (EFT=−5.76) when based on the inner-surface temperature, while it resulted in a better match (EFq=0.63) when based on the inner heat flux. Overall, the proposed framework provides a physically consistent and practically robust methodology for the dynamic thermal characterization of multilayer building walls using equivalent homogeneous models.

  • Open Access

    Development and validation of a non-contact method for U-value estimation in heritage and existing buildings

    by Luca Evangelisti, Edoardo De Cristo, Salvatore Monteleone, Claudia Guattari, Paola Gori, Tullio de Rubeis, Dario Ambrosini


  • Open Access

    In Situ Winter Performance and Annual Energy Assessment of an Ultra-Lightweight, Soil-Free Green Roof in Mediterranean Climate: Comparison with Traditional Roof Insulation

    by Luca Evangelisti, Edoardo De Cristo, Roberto De Lieto Vollaro

    Green roofs are effective passive strategies for enhancing building energy efficiency and indoor thermal comfort, particularly in response to climate change. This study presents an experimental and numerical assessment of an ultra-lightweight, soil-free green roof system for Mediterranean climates. In situ thermal monitoring was carried out on two identical test rooms in Rome (Italy), comparing the green roof to a traditional tiled roof under winter conditions. Results revealed a 45% reduction in thermal transmittance. These data were used to calibrate a dynamic TRNSYS 18 model and then applied to annual simulations of energy demand and indoor comfort across different roof configurations, including expanded polystyrene-insulated reference roofs. The model was calibrated in accordance with ASHRAE Guideline 14, achieving an MBE within ±10% and a CV(RMSE) within ±30% for hourly data, ensuring the simulation’s reliability. The green roof reduced cooling energy demand by up to 58.5% and heating demand by 11.6% relative to the uninsulated reference case. Compared to insulated roofs, it maintained similar winter performance while achieving summer operative temperature reductions up to 0.99 °C and PPD decreases up to 2.94%. By combining field measurements with calibrated simulations, this work provides evidence of the green roof’s effectiveness as a passive retrofit solution for Mediterranean buildings.


  • Top Cited Papers
    Open Access

    A Systematic Review of Green Roofs’ Thermal and Energy Performance in the Mediterranean Region

    by Edoardo De Cristo, Luca Evangelisti, Leone Barbaro, Roberto De Lieto Vollaro, Francesco Asdrubali

    Due to ongoing climate change, urban areas face increasing challenges associated with rising temperatures and growing energy demand. Green roofs have emerged as a sustainable, nature-based solution to enhance urban resilience. This study presents a systematic review of the thermal and energy performance of green roofs in the Mediterranean region, and was conducted following the PRISMA framework. By identifying targeted research questions formulated using the PICO(C) structure, this review systematically evaluates the potential of green roofs to promote sustainable urban environments in Mediterranean regions. The findings highlight their effectiveness in mitigating heat stress, enhancing building energy efficiency, and counteracting urban temperature fluctuations, reinforcing their role as a key climate adaptation strategy in densely populated areas. The review also identifies critical research gaps that must be addressed to facilitate the large-scale adoption of green roofs. Specifically, the lack of long-term performance monitoring, the need for standardized assessment protocols, and the necessity of optimizing green roof configurations for Mediterranean subregions emerge as key areas for future investigation. This study bridges a crucial gap in the literature by providing a systematic, PRISMA-compliant evaluation. It offers the scientific community a robust knowledge base to inform policy, urban planning, and future research directions.


  • Open Access

    A New Customized Measurement System for a Non-Contact, Enhanced Thermometric Method

    by Luca Evangelisti, Edoardo De Cristo, Salvatore Monteleone, Claudia Guattari, Paola Gori, Ivan Pini, Tullio de Rubeis, Dario Ambrosini

    This study introduces a novel, low-cost, non-contact measurement system for heat flux estimation based on an enhanced thermometric method. The customized system was designed and assembled to implement a non-contact, indirect approach for heat flux assessment. Developed as an affordable alternative to conventional contact-based techniques, it is suitable for historical buildings, where invasive sensors could compromise structural integrity. The system integrates real-time data acquisition, remote access via a web-based interface, and automated data processing, enhancing both usability and efficiency. Laboratory tests were conducted to evaluate its performance, with results compared against data from widely used heat flow plates and air/surface temperature sensors. The results showed good agreement between the proposed method and the reference data. Small differences were observed between the values measured by the air temperature sensors (0.10 °C on average), as well as by the contact and non-contact surface temperature sensors (0.12 °C on average). Finally, percentage variations between −6% and −5% in terms of heat fluxes confirmed the reliability of the non-contact approach. These findings provide a strong foundation for further testing, including applications in real buildings.


  • Open Access

    Preliminary development of a non-contact method for thermal characterization of building walls: Laboratory evaluation

    by Luca Evangelisti, Edoardo De Cristo, Claudia Guattari, Paola Gori, Tullio De Rubeis, Salvatore Monteleone


  • Thermal characterization of building walls using an equivalent modeling approach

    by Claudia Guattari, Edoardo De Cristo, Luca Evangelisti, Paola Gori, Roberta Jacoby Cureau, Claudia Fabiani, Anna Laura Pisello