Edoardo De Cristo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Edoardo De Cristo has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Luca Evangelisti
Department of Industrial, Electronic and Mechanical Engineering, Roma Tre University, Via Vito Volterra 62, 00146 Rome, Italy
12 shared publications - Claudia Guattari
Department of Philosophy, Communication and Performing Arts, Roma TRE University, Via Ostiense 139, 00154 Rome, Italy
6 shared publications - Roberto De Lieto Vollaro
Department of Industrial, Electronic and Mechanical Engineering, Roma Tre University, Via Vito Volterra 62, 00146 Rome, Italy
6 shared publications Claudia Guattari
5 shared publications- Paola Gori
Department of Industrial, Electronic and Mechanical Engineering, Roma Tre University, Via Vito Volterra 62, 00146 Rome, Italy
4 shared publications - Francesco Asdrubali
Department of International Human and Social Sciences, Perugia Foreigners’ University, Piazza Fortebraccio 4, 06122 Perugia, Italy
3 shared publications
Latest Publications
- Open Access
Research Trends in Thermal Comfort and Energy Efficiency in Buildings: An Editorial Overview
The transition towards a low-carbon built environment requires buildings to satisfy multiple performance objectives simultaneously
Open AccessResearch Trends in Thermal Comfort and Energy Efficiency in Buildings: An Editorial Overview
The transition towards a low-carbon built environment requires buildings to satisfy multiple performance objectives simultaneously
- Open Access
Inverse Identification of Equivalent Thermophysical Properties for Building Energy Analysis Under Dynamic Boundary Conditions
The evaluation of building energy performance under dynamic conditions requires reliable estimates of the thermophysical properties of envelope components. In existing buildings, however, the properties of multilayer walls are often unknown or uncertain, limiting the applicability of detailed physical models. To address this issue, this study proposes an inverse modeling framework for identifying the equivalent thermophysical parameters of a multilayer wall through a simplified homogeneous one-dimensional conduction model. The equivalent parameters are determined by matching the inner-side dynamic thermal response of the homogeneous model to that of the actual multilayer structure under the same external excitation. The approach explicitly accounts for the role of inner boundary conditions, which govern both the identifiability of the equivalent parameters and the formulation of the inverse problem. Adiabatic, isothermal, and more general inner boundary conditions are analyzed to determine how many independent parameters can be reliably identified and which response variables should be used in the objective function. Synthetic datasets, generated via numerical simulations driven by real weather data, are first employed to assess the method and to quantify the effect of transient initialization. The framework is then applied to experimental measurements collected from a full-scale test room. The results show that, under adiabatic conditions, the wall dynamics can be accurately reproduced by identifying a single equivalent thermal diffusivity, whereas isothermal and near-isothermal conditions require the simultaneous estimation of thermal conductivity and volumetric heat capacity. Moreover, the analysis demonstrates that inverse formulations based on inner heat flux are significantly more robust than temperature-based formulations, particularly when the inner-surface temperature is weakly varying or tightly controlled, as commonly occurs in real buildings. In a nearly isothermal experimental case, the inverse identification failed () when based on the inner-surface temperature, while it resulted in a better match () when based on the inner heat flux. Overall, the proposed framework provides a physically consistent and practically robust methodology for the dynamic thermal characterization of multilayer building walls using equivalent homogeneous models.Open AccessInverse Identification of Equivalent Thermophysical Properties for Building Energy Analysis Under Dynamic Boundary Conditions
The evaluation of building energy performance under dynamic conditions requires reliable estimates of the thermophysical properties of envelope components. In existing buildings, however, the properties of multilayer walls are often unknown or uncertain, limiting the applicability of detailed physical models. To address this issue, this study proposes an inverse modeling framework for identifying the equivalent thermophysical parameters of a multilayer wall through a simplified homogeneous one-dimensional conduction model. The equivalent parameters are determined by matching the inner-side dynamic thermal response of the homogeneous model to that of the actual multilayer structure under the same external excitation. The approach explicitly accounts for the role of inner boundary conditions, which govern both the identifiability of the equivalent parameters and the formulation of the inverse problem. Adiabatic, isothermal, and more general inner boundary conditions are analyzed to determine how many independent parameters can be reliably identified and which response variables should be used in the objective function. Synthetic datasets, generated via numerical simulations driven by real weather data, are first employed to assess the method and to quantify the effect of transient initialization. The framework is then applied to experimental measurements collected from a full-scale test room. The results show that, under adiabatic conditions, the wall dynamics can be accurately reproduced by identifying a single equivalent thermal diffusivity, whereas isothermal and near-isothermal conditions require the simultaneous estimation of thermal conductivity and volumetric heat capacity. Moreover, the analysis demonstrates that inverse formulations based on inner heat flux are significantly more robust than temperature-based formulations, particularly when the inner-surface temperature is weakly varying or tightly controlled, as commonly occurs in real buildings. In a nearly isothermal experimental case, the inverse identification failed () when based on the inner-surface temperature, while it resulted in a better match () when based on the inner heat flux. Overall, the proposed framework provides a physically consistent and practically robust methodology for the dynamic thermal characterization of multilayer building walls using equivalent homogeneous models. - Open Access
- 14 September 2025
- Published by Elsevier in Results in Engineering
- Vol. 28
Development and validation of a non-contact method for U-value estimation in heritage and existing buildings
- 14 September 2025
- Published by Elsevier in Results in Engineering
- Vol. 28
Open AccessDevelopment and validation of a non-contact method for U-value estimation in heritage and existing buildings
- Open Access
In Situ Winter Performance and Annual Energy Assessment of an Ultra-Lightweight, Soil-Free Green Roof in Mediterranean Climate: Comparison with Traditional Roof Insulation
Green roofs are effective passive strategies for enhancing building energy efficiency and indoor thermal comfort, particularly in response to climate change. This study presents an experimental and numerical assessment of an ultra-lightweight, soil-free green roof system for Mediterranean climates. In situ thermal monitoring was carried out on two identical test rooms in Rome (Italy), comparing the green roof to a traditional tiled roof under winter conditions. Results revealed a 45% reduction in thermal transmittance. These data were used to calibrate a dynamic TRNSYS 18 model and then applied to annual simulations of energy demand and indoor comfort across different roof configurations, including expanded polystyrene-insulated reference roofs. The model was calibrated in accordance with ASHRAE Guideline 14, achieving an MBE within ±10% and a CV(RMSE) within ±30% for hourly data, ensuring the simulation’s reliability. The green roof reduced cooling energy demand by up to 58.5% and heating demand by 11.6% relative to the uninsulated reference case. Compared to insulated roofs, it maintained similar winter performance while achieving summer operative temperature reductions up to 0.99 °C and PPD decreases up to 2.94%. By combining field measurements with calibrated simulations, this work provides evidence of the green roof’s effectiveness as a passive retrofit solution for Mediterranean buildings.
Open AccessIn Situ Winter Performance and Annual Energy Assessment of an Ultra-Lightweight, Soil-Free Green Roof in Mediterranean Climate: Comparison with Traditional Roof Insulation
Green roofs are effective passive strategies for enhancing building energy efficiency and indoor thermal comfort, particularly in response to climate change. This study presents an experimental and numerical assessment of an ultra-lightweight, soil-free green roof system for Mediterranean climates. In situ thermal monitoring was carried out on two identical test rooms in Rome (Italy), comparing the green roof to a traditional tiled roof under winter conditions. Results revealed a 45% reduction in thermal transmittance. These data were used to calibrate a dynamic TRNSYS 18 model and then applied to annual simulations of energy demand and indoor comfort across different roof configurations, including expanded polystyrene-insulated reference roofs. The model was calibrated in accordance with ASHRAE Guideline 14, achieving an MBE within ±10% and a CV(RMSE) within ±30% for hourly data, ensuring the simulation’s reliability. The green roof reduced cooling energy demand by up to 58.5% and heating demand by 11.6% relative to the uninsulated reference case. Compared to insulated roofs, it maintained similar winter performance while achieving summer operative temperature reductions up to 0.99 °C and PPD decreases up to 2.94%. By combining field measurements with calibrated simulations, this work provides evidence of the green roof’s effectiveness as a passive retrofit solution for Mediterranean buildings.
- Top Cited PapersOpen Access
A Systematic Review of Green Roofs’ Thermal and Energy Performance in the Mediterranean Region
Due to ongoing climate change, urban areas face increasing challenges associated with rising temperatures and growing energy demand. Green roofs have emerged as a sustainable, nature-based solution to enhance urban resilience. This study presents a systematic review of the thermal and energy performance of green roofs in the Mediterranean region, and was conducted following the PRISMA framework. By identifying targeted research questions formulated using the PICO(C) structure, this review systematically evaluates the potential of green roofs to promote sustainable urban environments in Mediterranean regions. The findings highlight their effectiveness in mitigating heat stress, enhancing building energy efficiency, and counteracting urban temperature fluctuations, reinforcing their role as a key climate adaptation strategy in densely populated areas. The review also identifies critical research gaps that must be addressed to facilitate the large-scale adoption of green roofs. Specifically, the lack of long-term performance monitoring, the need for standardized assessment protocols, and the necessity of optimizing green roof configurations for Mediterranean subregions emerge as key areas for future investigation. This study bridges a crucial gap in the literature by providing a systematic, PRISMA-compliant evaluation. It offers the scientific community a robust knowledge base to inform policy, urban planning, and future research directions.
Top Cited PapersOpen AccessA Systematic Review of Green Roofs’ Thermal and Energy Performance in the Mediterranean Region
Due to ongoing climate change, urban areas face increasing challenges associated with rising temperatures and growing energy demand. Green roofs have emerged as a sustainable, nature-based solution to enhance urban resilience. This study presents a systematic review of the thermal and energy performance of green roofs in the Mediterranean region, and was conducted following the PRISMA framework. By identifying targeted research questions formulated using the PICO(C) structure, this review systematically evaluates the potential of green roofs to promote sustainable urban environments in Mediterranean regions. The findings highlight their effectiveness in mitigating heat stress, enhancing building energy efficiency, and counteracting urban temperature fluctuations, reinforcing their role as a key climate adaptation strategy in densely populated areas. The review also identifies critical research gaps that must be addressed to facilitate the large-scale adoption of green roofs. Specifically, the lack of long-term performance monitoring, the need for standardized assessment protocols, and the necessity of optimizing green roof configurations for Mediterranean subregions emerge as key areas for future investigation. This study bridges a crucial gap in the literature by providing a systematic, PRISMA-compliant evaluation. It offers the scientific community a robust knowledge base to inform policy, urban planning, and future research directions.
- Open Access
A New Customized Measurement System for a Non-Contact, Enhanced Thermometric Method
This study introduces a novel, low-cost, non-contact measurement system for heat flux estimation based on an enhanced thermometric method. The customized system was designed and assembled to implement a non-contact, indirect approach for heat flux assessment. Developed as an affordable alternative to conventional contact-based techniques, it is suitable for historical buildings, where invasive sensors could compromise structural integrity. The system integrates real-time data acquisition, remote access via a web-based interface, and automated data processing, enhancing both usability and efficiency. Laboratory tests were conducted to evaluate its performance, with results compared against data from widely used heat flow plates and air/surface temperature sensors. The results showed good agreement between the proposed method and the reference data. Small differences were observed between the values measured by the air temperature sensors (0.10 °C on average), as well as by the contact and non-contact surface temperature sensors (0.12 °C on average). Finally, percentage variations between −6% and −5% in terms of heat fluxes confirmed the reliability of the non-contact approach. These findings provide a strong foundation for further testing, including applications in real buildings.
Open AccessA New Customized Measurement System for a Non-Contact, Enhanced Thermometric Method
This study introduces a novel, low-cost, non-contact measurement system for heat flux estimation based on an enhanced thermometric method. The customized system was designed and assembled to implement a non-contact, indirect approach for heat flux assessment. Developed as an affordable alternative to conventional contact-based techniques, it is suitable for historical buildings, where invasive sensors could compromise structural integrity. The system integrates real-time data acquisition, remote access via a web-based interface, and automated data processing, enhancing both usability and efficiency. Laboratory tests were conducted to evaluate its performance, with results compared against data from widely used heat flow plates and air/surface temperature sensors. The results showed good agreement between the proposed method and the reference data. Small differences were observed between the values measured by the air temperature sensors (0.10 °C on average), as well as by the contact and non-contact surface temperature sensors (0.12 °C on average). Finally, percentage variations between −6% and −5% in terms of heat fluxes confirmed the reliability of the non-contact approach. These findings provide a strong foundation for further testing, including applications in real buildings.
- Open Access
- 10 March 2025
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 69
Preliminary development of a non-contact method for thermal characterization of building walls: Laboratory evaluation
- 10 March 2025
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 69
Open AccessPreliminary development of a non-contact method for thermal characterization of building walls: Laboratory evaluation
- 24 December 2024
- Published by Elsevier in Energy and Buildings
- Vol. 329
Thermal characterization of building walls using an equivalent modeling approach
- 24 December 2024
- Published by Elsevier in Energy and Buildings
- Vol. 329
Thermal characterization of building walls using an equivalent modeling approach