CDCourtney J. Duckworth

Courtney J. Duckworth

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Courtney J. Duckworth has a total of 33 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • An Atypical Presentation of Cytokine Release Syndrome With Signs of Arthritis During Treatment With Teplizumab in a Pediatric Patient

    by Courtney J. Duckworth, Raymond J. Kreienkamp, Evan C. Rieger, Thinh H. Nguyen, Jason L. Gaglia, Belinda S. Lennerz


  • Open Access

    The thermoneutral zone in women takes an “arctic” shift compared to men

    by Robert J. Brychta, Suzanne McGehee, Shan Huang, Brooks P. Leitner, Courtney J. Duckworth, Laura A. Fletcher, Katherine Kim, Thomas M. Cassimatis, Nikita S. Israni, Hannah J. Lea, et al.

    Conventionally, women are perceived to feel colder than men, but controlled comparisons are sparse. We measured the response of healthy, lean, young women and men to a range of ambient temperatures typical of the daily environment (17 to 31 °C). The Scholander model of thermoregulation defines the lower critical temperature as threshold of the thermoneutral zone, below which additional heat production is required to defend core body temperature. This parameter can be used to characterize the thermoregulatory phenotypes of endotherms on a spectrum from “arctic” to “tropical.” We found that women had a cooler lower critical temperature (mean ± SD: 21.9 ± 1.3 °C vs. 22.9 ± 1.2 °C, P = 0.047), resembling an “arctic” shift compared to men. The more arctic profile of women was predominantly driven by higher insulation associated with more body fat compared to men, countering the lower basal metabolic rate associated with their smaller body size, which typically favors a “tropical” shift. We did not detect sex-based differences in secondary measures of thermoregulation including brown adipose tissue glucose uptake, muscle electrical activity, skin temperatures, cold-induced thermogenesis, or self-reported thermal comfort. In conclusion, the principal contributors to individual differences in human thermoregulation are physical attributes, including body size and composition, which may be partly mediated by sex.


  • Open Access

    P ET CO 2 In Women at Sea‐Level and Upon Acute Exposure to Normobaric Hypoxic Environments Simulating 3,500 m

    by Ken Kambis, Michio Yasukawa, Thomas Moran, Austen Pleasant, Gabriella Hafner, Veronique Barbour, Courtney Duckworth, Stephen Muza, Robin Looft‐Wilson

    A prior study in men (Reeves, J. Appl. Physiol. 75: 1993) demonstrated that the ventilatory response to high altitude is highly variable among sea level residents, but the sea level end‐tidal PCO 2 (P ET CO 2 , a measurement of effective alveolar ventilation) is highly predictive of subsequent ventilation at high altitude. While prior work suggests that women and men have similar ventilatory responses to high altitude (Muza, J. Appl. Physiol. 91: 2001), no studies have determined if women's sea level P ET CO 2 is predictive of subsequent ventilation at high altitude. As part of a larger study examining individual variability upon acute exposure to normobaric hypoxia, P ET CO 2 was measured while subjects rested for >30 minutes at sea level (SL) and, no sooner than two days later, for >30 minutes in a normobaric hypoxia chamber at 13.55% FiO 2 approximating oxygen partial pressures equivalent to those found at 3,500 m, or at a FiO 2 of 20.93% in the case of control subjects. METHODS: Informed volunteer female subjects participated in this IRB approved study. 47 (20.6±1.5 yr.; 165.6±6.9 cm; 62.9±10.4 kg; 22.9±3.4 kg/m 2 ; VO 2peak 42.6±7.4 ml/kg −1 /min −1 ) subjects were assigned to the treatment group who were tested at SL then entered the normobaric chamber where the FiO 2 =13.55% (HYPO) and 9 subjects (21.8±4.3 yr.; 166.5±6.1 cm; 57.9 ±7.0 kg; 20.9 ±2.1 kg/m 2 ; VO 2peak 40.9 ±6.5 ml/kg −1 /min −1 ) acted as controls (SHAM) who were in the normobaric chamber at a FiO 2 = 20.93%. At both SL and chamber conditions, subjects rested for >30 minutes. P ET CO 2 was measured during the final 14 minutes of each rest period as was percent hemoglobin O 2 saturation (SpO 2) , respiratory rate (RR), and heart rate (HR). RESULTS: Two‐way RM ANOVA revealed that there was no difference (P>0.5) in P ET CO 2 between the HYPO vs SHAM groups at SL (37.9±2.7 vs 36.0±2.9) but, as expected, there was a difference (PET CO 2 = 37.9±2.7 vs 36.0±2.2) in the HYPO group. A significant (P < 0.001) Pearson correlation (r = 0.759) was also observed between SL P ET CO 2 and HYPO P ET CO 2 while no difference was observed between the SHAM conditions. A multiple regression model [Y = 79.617 – 0.452 X 1 – 0.207 X 2 – 0.016 X 3 (Where Y= P ET CO 2 _HYPO, X 1 = SpO 2 _HYPO, X 2 = RR_HYPO, X 3 = HR_HYPO; R 2 = 0.500, F = 19.15, P < 0.001)] was used to plot the actual and predictive values for P ET CO 2 at 3,500 m (). CONCLUSIONS: Women's SL P ET CO 2 is predictive of their ventilatory response to acute normobaric hypoxia and may be useful in predicting an individual's ventilation during travel to moderately high altitudes. Support or Funding Information The Doug Morton/Marilyn Brown Endowment for Biomedical Research, The Foundation for Aging Studies and Exercise Science Research, and The Borgenicht Program