ZWZejun Wu

Zejun Wu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Zejun Wu has a total of 32 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A wavelet-guided diffusion method for brain magnetic resonance parameter mapping using MOLED-based datasets: proof-of-principle

    by Che Wang, Linyu Fan, Qizhi Yang, Zejun Wu, Yiru Lin, Yong Zhang, Congbo Cai, Jianfeng Bao, Shuhui Cai

    Objective. Quantitative magnetic resonance imaging (qMRI) can noninvasively acquire parametric maps, providing quantitative biomarkers for clinical assessment. Parametric maps, such as T 2 , T 2 * , and apparent diffusion coefficient (ADC), characterize distinct biophysical processes in tissue in an interpretable, numerical manner. Owing to their distinct physical origins, various parametric maps differ in physical units, numerical magnitudes, and dynamic ranges. Even for the same type of parametric map, inter-subject differences may still exist in anatomical morphology, tissue characteristics, and the local distributions of parameter values. However, deep learning methods trained in image-domain directly learn pixel-level parameter values, and variations in numerical scales and subject-specific parameter distributions may result in anatomical detail loss and localized artifacts in certain tasks. To address this challenge and to deliver dependable quantitative references for clinical assessment, we propose a wavelet-guided diffusion method. Approach. We extend the discrete convolution wavelet transform (DCWT) to two dimensions and combine it with a conditional denoising diffusion method to develop a diffusion-based DCWT (Diff-DCWT) for parameter mapping. Diff-DCWT achieves accurate parameter mapping under the guidance of wavelet coefficient maps, thereby reducing reliance on image domain learning. The performance of Diff-DCWT is evaluated through simulation and in vivo experiments across T 2 , T 2 * , and ADC mapping tasks. Main Results. Both simulation and healthy volunteer experiments demonstrate that T 2 , T 2 * , and ADC maps obtained from Diff-DCWT maintain excellent visual quality and quantitative accuracy. Clinical case studies suggest the potential utility of Diff-DCWT-derived T 2 and ADC maps for stroke staging and help distinguish lesional from normal brain regions in glioma. Significance. Diff-DCWT establishes a high-fidelity framework for parameter mapping and exhibits preliminary clinical value in stroke staging and glioma characterization. Moreover, this work demonstrates the potential of wavelet-domain prior guidance for deep learning-based qMRI applications.

  • Rapid whole-brain susceptibility source separation using sub-minute three-dimensional multiple overlapping-echo detachment acquisition

    by Longkun Chen, Qinqin Yang, Shiwei Huang, Nuowei Ge, Zejun Wu, Jianjun Zhou, Jianfeng Bao, Lijun Bao, Yuanhao Cheng, Jianfa Chen, et al.

    Objective. Magnetic susceptibility source separation provides profound insights into tissue pathophysiology by disentangling the underlying paramagnetic and diamagnetic sources within the human brain. However, the highly time-consuming nature of existing acquisition techniques creates a critical need for rapid and reliable separation methodologies to facilitate routine clinical applications. Approach. A highly accelerated framework for whole-brain magnetic susceptibility source separation was proposed by utilizing the ultra-fast 3D-MOLED sequence. This pipeline integrates the advanced deep learning architecture to accurately map the separated susceptibility components without relying on spin echo data. To ensure quantitative stability and structural fidelity, a robust three-dimensional domain adaptation strategy was incorporated during the simulation phase. The performance of the proposed method was systematically evaluated through phantom experiments, healthy volunteer assessments, and clinical examinations of patients with multiple sclerosis. Main results. The proposed framework achieved whole-brain susceptibility source separation at 1 mm isotropic resolution with only 50 s of data acquisition. In healthy volunteers, the paramagnetic and diamagnetic susceptibility maps were highly comparable to those obtained with the conventional multi-echo gradient-echo sequence, with structural similarity indices of 0.9244 ± 0.0181 and 0.9425 ± 0.0186, peak signal-to-noise ratios of 33.76 ± 2.37 and 37.29 ± 3.51 dB, regional coefficients of determination of 0.973 and 0.934, and Bland–Altman biases of −0.0013 and −0.0010 ppm, respectively. Furthermore, clinical evaluations in patients with multiple sclerosis demonstrated consistent characterization of complex lesion-related susceptibility features. Significance. Achieving whole-brain magnetic susceptibility source separation in less than one minute represents a meaningful technical advance. By substantially reducing the acquisition time required for susceptibility source separation, this accelerated framework may improve the feasibility of future clinical translation in neuroimaging workflows.

  • Model-based spatiotemporal synthetic data generation framework and deep-learning reconstruction for real-time MRI oxygen extraction fraction mapping

    by Zejun Wu, Qinqin Yang, Nuowei Ge, Jiechao Wang, Liuhong Zhu, Jianjun Zhou, Jian-Feng Bao, Jianfa Chen, Lina Xu, Zhong Chen, et al.

    Objective: Synthetic data has emerged as a highly efficient solution to address the scarcity of training data in deep learning-based quantitative magnetic resonance imaging (qMRI) reconstruction. However, current applications of synthetic data predominantly focus on two-dimensional spatial reconstruction, with limited capability to leverage the spatiotemporal correlation inherent in real-time dynamic imaging data to further enhance reconstruction quality. Approach: A model-based spatiotemporal synthetic data generation framework tailored for real-time dynamic scenarios in supervised learning-based reconstruction was proposed. This framework is complemented by an ultra-fast multiple overlapping-echo detachment (MOLED) imaging technique, which enables a three-dimensional spatiotemporal reconstruction method designed to track dynamic changes in the oxygen extraction fraction (OEF). The proposed method imposes constraints that align the predicted parameters with the ground truth while ensuring consistency in their singular-value subspaces. Main results: The accuracy and effectiveness of the proposed method for T2 and T2* mapping were validated through numerical brain, water phantom and human brain experiments, demonstrating superior performance compared to both traditional two-dimensional spatial and three-dimensional spatiotemporal reconstruction methods. This framework reliably enabled dynamic OEF tracking during breath-hold and oxygen inhalation cycles, highlighting its robustness and applicability in real-time scenarios. Significance: The model-based spatiotemporal synthetic data generation framework and the spatiotemporal reconstruction method offer an effective and robust solution for real-time qMRI, with potential applications in other similar real-time dynamic quantitative reconstruction tasks. Moreover, the MOLED sequence underscores the potential for precise and dynamic measurement of brain oxygen metabolism, providing valuable insights into cerebral physiology and metabolic changes.


  • Bridging synthetic and real images: a transferable domain adaptation method for multi-parametric mapping via multiple overlapping-echo detachment imaging

    by Junbo Zeng, Yudan Zhou, Ming Ye, Zejun Wu, Congbo Cai, Shuhui Cai

    Objective. This study aims to address the challenge of domain discrepancies between synthetic and real data in quantitative MRI, particularly in multi-parametric mapping using multiple overlapping-echo detachment (MOLED) imaging, which provides rapid and versatile imaging for clinical applications. Approach. A domain adaptation method named MaskedUnet was proposed. Specifically, we employed a mask-based self-supervised pre-training model to learn knowledge from unlabeled real MOLED images. Guided by the learned knowledge of the real data distribution, we regenerated synthetic data closer to the real data distribution to enhance the model’s generalization ability to real data. Evaluations were performed on T 2 and T 2 * MOLED imaging data of two healthy brain volunteers, T 2 and apparent diffusion coefficient (ADC) MOLED imaging data of a healthy brain volunteer, and T 2 and ADC MOLED imaging data of 24 patients with brain tumors from 3T MRI scanners were performed, and the results were compared with existing methods to evaluate the effectiveness of the proposed method. Main results. Experimental results demonstrate the effectiveness of the proposed method for MOLED imaging, significantly reducing noise and eliminating streaking artifacts. The normalized mean square error, peak signal-to-noise ratio and structural similarity index of the reconstructed quantitative maps from our method are 0.2170/0.1624, 18.2492/22.7896 dB, 0.7744/0.8162 respectively for T 2/T 2 * of the healthy participants, 0.2423/0.0893, 17.3168/21.9115 dB, 0.7655/0.8416 respectively for T 2/ADC of the healthy participant, and 0.1344, 21.2407 dB, 0.8333 respectively for ADC of the healthy participant. Significance. MaskedUnet demonstrates the feasibility to bridge the gap between synthetic and real MOLED data, advancing the application of multi-parametric MOLED quantitative imaging.


  • FlexDTI: flexible diffusion gradient encoding scheme-based highly efficient diffusion tensor imaging using deep learning

    by Zejun Wu, Jiechao Wang, Zunquan Chen, Qinqin Yang, Zhen Xing, Dairong Cao, Jianfeng Bao, Taishan Kang, Jianzhong Lin, Shuhui Cai, et al.

    Objective . Most deep neural network-based diffusion tensor imaging methods require the diffusion gradients’ number and directions in the data to be reconstructed to match those in the training data. This work aims to develop and evaluate a novel dynamic-convolution-based method called FlexDTI for highly efficient diffusion tensor reconstruction with flexible diffusion encoding gradient scheme. Approach . FlexDTI was developed to achieve high-quality DTI parametric mapping with flexible number and directions of diffusion encoding gradients. The method used dynamic convolution kernels to embed diffusion gradient direction information into feature maps of the corresponding diffusion signal. Furthermore, it realized the generalization of a flexible number of diffusion gradient directions by setting the maximum number of input channels of the network. The network was trained and tested using datasets from the Human Connectome Project and local hospitals. Results from FlexDTI and other advanced tensor parameter estimation methods were compared. Main results . Compared to other methods, FlexDTI successfully achieves high-quality diffusion tensor-derived parameters even if the number and directions of diffusion encoding gradients change. It reduces normalized root mean squared error by about 50% on fractional anisotropy and 15% on mean diffusivity, compared with the state-of-the-art deep learning method with flexible diffusion encoding gradient scheme. Significance . FlexDTI can well learn diffusion gradient direction information to achieve generalized DTI reconstruction with flexible diffusion gradient scheme. Both flexibility and reconstruction quality can be taken into account in this network.